Connection String Designer Code
May 2, 2008
I currently have the following code in my designer file
<asp:SqlDataSource ID="SqlDataSource1" Runat="server" SelectCommand="select Site_name, system_id, ASP_Archive, sitetimes,
HPOV_ROC, UPPER(CircuitType) as CircuitType, QwestCircuit_ID,
SiteConfig,Site_Nat, PVC_VCI from tblASPCustomerWan order by Asp_Archive asc"
UpdateCommand="UPDATE tblASPCustomerWan SET [Site_name] = @Site_name, [system_id] = @system_id, [ASP_Archive] = @ASP_Archive, [sitetimes] = @sitetimes, [HPOV_ROC] = @HPOV_ROC, [CircuitType] = @CircuitType, [QwestCircuit_ID] = @QwestCircuit_ID, [SiteConfig]= @SiteConfig, [Site_Nat]=@Site_Nat,
[PVC_VCI]=@PVC_VCI"
ConnectionString="server=localhost;Trusted_Connection=yes;uid=portal_user;pwd=Cr@zyP@55w0rd;database=CusPortal_Staging" />
I would like the change the connection so it takes it value from System.Configuration.ConfigurationManager.AppSettings("appStrConnection"), how can i do that??
View 1 Replies
ADVERTISEMENT
Apr 19, 2008
hi,
i was able to succesfully configure my remote server over the internet and tried using express edition to connect to my remote server and everything when successful.
is there a way to copy that connection string used to connect to my remote server so as i wanted to create a project in vb using that connection string..
where can i find the connection string code used for my connection remotely ..
i am using express to connect to my sql server
thanks
View 4 Replies
View Related
May 15, 2007
Every time I move my project from my computer to the testing server I have to change the connection string references in the aspx side and in my code behind.
For the code behind I declared the SqlConnection string at the top of the code-behind page for both connection strings and comment out the one not in use. Obviously I then comment out the string not in use in the WebConfig as well.
Being superlatively lazy I always look for the easiest and quickest way to do most anything - connection strings included. Having to comment out strings twice brought rise to the question of whether I can refer to the connection string in the web.config file from the code-behind page. I'm sure it can be done, and I did a good amount of hunting around, but I couldn't find any examples of code that would do that.
Currently, as I said above, I have two connection strings declared at the top of my code-behind. Here's an example of one:Private sqlConn As New SqlConnection("Data Source=DATABASESERVER;Initial Catalog=DATABASE;User ID=USER;Password=PASSWORD")
Then, I just use sqlConn as usual in my binding without having to "dim" it in every sub:sdaPersonnel = New SqlDataAdapter(strSqlPersonnel, sqlConn)
Then there's the SqlConnections set up by the wizard on the aspx side:<asp:SqlDataSource ID="sqlDataSourcePayrollCompany" Runat="Server" ConnectionString="<%$ ConnectionStrings:DATABASECONNECTIONSTRING %>" ...>
And for the connection in the web.config:<add name="DATABASECONNECTIONSTRING" connectionString="Data Source=DATABASESERVER;Initial Catalog=DATABASE;User ID=USER;Password=PASSWORD" providerName="System.Data.SqlClient" />
So, what would be the code in the code-behind page to refer to the connection string in the web.config file?
Thanks!
View 2 Replies
View Related
Feb 28, 2008
I have written a CLR function in C# to access a sql server different from the current server where I have deplyed the assembly.
DataSet ds = new DataSet();
SqlCommand sqlCmd = new SqlCommand();
sqlCmd.CommandType = CommandType.StoredProcedure;
string connString = "Data Source=SQLSERVER;Initial Catalog=DATABASE;User ID=userid;Password=password;";
SqlConnection sqlConn = new SqlConnection(connString);
sqlCmd.Connection = sqlConn;
sqlConn.Open();
try
{
SqlDataAdapter sda = new SqlDataAdapter();
sqlCmd.CommandText = "StoredProcedureName";
sqlCmd.Parameters.Add("@Param1", SqlDbType.VarChar);
sqlCmd.Parameters["@Param1"].Value = sParam1;
sda.SelectCommand = sqlCmd;
sda.Fill(ds);
}
finally
{
sqlConn.Close();
}
return ds;
I was getting the following error
"Request for the permission of type 'System.Data.SqlClient.SqlClientPermission, System.Data, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089' failed."
so I tried doing the following
SqlClientPermission pSql = new SqlClientPermission(System.Security.Permissions.PermissionState.Unrestricted);
pSql.Assert();
and then I get this error
"Request for the permission of type 'System.Security.Permissions.SecurityPermission, mscorlib, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089' failed."
Any idea how to remedy this ?
Thanks in advance
- Kan
View 4 Replies
View Related
Apr 15, 2008
Hi all,
Please help me for the code of connectivity
it was working fine,but,when i hav written code for validation for id n password,its showing error as
Violation of PRIMARY KEY constraint 'PK_Login'. Cannot insert duplicate key in object 'login_detail'. The statement has been terminated.
Here is my code given below.
Please help me
Imports System
Imports System.IO
Imports System.Xml
Imports System.Text
Imports System.Security.Cryptography
Imports System.Web.UI.WebControls
Imports System.Web.UI.HtmlControls
Imports System.Data
Imports System.Data.SqlClientPublic Class WebForm1
Inherits System.Web.UI.Page#Region " Web Form Designer Generated Code "
'This call is required by the Web Form Designer.<System.Diagnostics.DebuggerStepThrough()> Private Sub InitializeComponent()
End SubProtected WithEvents txtUser As System.Web.UI.WebControls.TextBox
Protected WithEvents txtPwd As System.Web.UI.WebControls.TextBoxProtected WithEvents btnSubmit As System.Web.UI.WebControls.Button
Protected WithEvents lblError As System.Web.UI.WebControls.Label
'NOTE: The following placeholder declaration is required by the Web Form Designer.
'Do not delete or move it.Private designerPlaceholderDeclaration As System.Object
Private Sub Page_Init(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles MyBase.Init
'CODEGEN: This method call is required by the Web Form Designer
'Do not modify it using the code editor.
InitializeComponent()
End Sub
#End RegionPrivate Sub Page_Load(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles MyBase.Load
'Put user code to initialize the page here
Dim objConn As SqlClient.SqlConnection
Dim ds As New DataSetDim m_strConnection As String = "server=172.16.152.17;Database=Trial;UID=abhi_Asset4;PWD=L!nux001;Connect Timeout=100"objConn = New SqlClient.SqlConnection
objConn.ConnectionString = m_strConnection
objConn.Open()
Dim strSQL As String
strSQL = "insert into login_detail(UserID,Password) values('" + txtUser.Text + "','" + txtPwd.Text + "')"Dim objCommand As SqlClient.SqlCommandobjCommand = New SqlClient.SqlCommand(strSQL, objConn)
objCommand.CommandText = strSQL
objCommand.ExecuteNonQuery()
objConn.Close()
End SubPrivate Sub btnSubmit_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles btnSubmit.Click
If (txtUser.Text.Trim() = "") Then
lblError.Text = "UserID should not be blank"
ElseIf (Convert.ToInt32(txtUser.Text.Length) < 5) Then
lblError.Text = "UserID length must be more than 5"
ElseIf (Convert.ToInt32(txtUser.Text.Length) > 20) Then
lblError.Text = "UserID length must not be greater than 20"
ElseIf (txtPwd.Text.Trim() = "") Then
lblError.Text = "Password should not be blank"
ElseIf (Convert.ToInt32(txtPwd.Text.Length) < 5) Then
lblError.Text = "Password length must be more than 5"
ElseIf (Convert.ToInt32(txtPwd.Text.Length) > 20) Then
lblError.Text = "Password length must not be greater than 20"
Else
Server.Transfer("Success.aspx")
End IfEnd Sub
End Class
View 1 Replies
View Related
Apr 2, 2008
When using a typed dataset in VS 2005 with SqlCe 3.1, it conitinues to make the param.dbtype for the GUID to be an 'object'. When as far as I can tell it needs to be a 'Guid' dbtype. So each time I modify the typed dataset I go in and manually change the various bugs and things work fine. My question is whether or not anyone knows a better work around for this after finding themselves in this situation.
I've attached a code sample of the erroneous designer code, and highlighted the line that should instead be set to DbType.Guid.
Code Snippet
global::System.Data.SqlServerCe.SqlCeParameter param = new global::System.Data.SqlServerCe.SqlCeParameter();
param.ParameterName = "@ProjectQuoteGUID";
param.DbType = global::System.Data.DbType.Object;
param.Size = 16;
param.IsNullable = true;
param.SourceColumn = "ProjectQuoteGUID";
this._commandCollection[1].Parameters.Add(param);
Thanks
View 2 Replies
View Related
Mar 28, 2007
I have 2 data sources that have recently been updated from SQL Express to full versions of 2005. The connection strings have been changed, and the changes appear in the code, but the data source designer still shows the SQLExpress portion of the connection string. This seems to be fouling up SSIS packages that are using these data sources. Has anyone else encountered this? If so, what can I do to fix this issue?
View 4 Replies
View Related
Oct 3, 2005
Problem Description: The following error is popping up and not allowing opening or running any of the DTS packages. Connection objects are not available in DTS Designer.
"Error in the DLL"
"Need to run the object to perform this operation"
We have reinstalled the MS SQL Server 2000 Standard Edition with Service pack 3 and MSO3031 hot fix. Still the issue continues.
Operating System:Windows 2000
View 2 Replies
View Related
Aug 23, 2006
I added a connection (ADO.NET) object by name testCon in the connection manager - I wanted to programmatically supply the connection string. So I used the "Expressions" property of the connection object and set the connectionstring to one DTS variable. The idea is to supply the connection string value to the variable - so that the connection object uses my connection string.
Then I added a "Backup Database Task" to my package with the name BkpTask. Now whenever I try to set the connection property of BkpTask to the testCon connection object, by typing testCon, it automatically gets cleared. I am not able to set the connection value.
Then after spending several hours I found that this is because I have customized the connection string in testCon. If I don't customize the connection string, I am able to enter the "testCon" value in the connection property of the BkpTask.
Is this an intrinsic issue?
View 2 Replies
View Related
Jan 24, 2007
64b SQL2005 EE and all clent tools installed on the same server. Im trying to create a new connection in DTS Designer but after succesful test of the connection it errors out with
The new connection manager couldnt be created. Additional info : Exeption from HRESULT 0xC0010014
Any idea whats the problem here?
View 3 Replies
View Related
Feb 14, 2008
Hi All,
I am getting the following error if I am using the package "Transaction Option=Required" while running through Sql Job:
The AcquireConnection method call to the connection manager "<connection name>" failed with error code 0xC0202009.
while I running the SSIS package on BI environment, I am getting the following error:
[Connection manager "<connection name>"] Error: The SSIS Runtime has failed to enlist the OLE DB connection in a distributed transaction with error 0x8004D00A "Unable to enlist in the transaction.".
I know the alternative solution is to make the "Transaction Option=Supported", but in my case I have run the whole flow in a single transaction. I came to know that this has been fixed in the service pack1(ref. to http://support.microsoft.com/kb/914375). FYI.. some time it was running successful.
I have taken all the necessary step to run the SSIS package in a distributed transaction(like the steps for MSDTC) and also created the package flow in a sequence.
I was going through the link - http://forums.microsoft.com/MSDN/ShowPost.aspx?PostID=160340&SiteID=1 but all those didn't solve my problem.
If anyone can help me it will be great. or it is a bug in SSIS?
Thanks.
Jena
View 5 Replies
View Related
Jun 14, 2006
While Creating a script task in Control Flow, I am getting "Package Validation Error". Here is the complete message:
Error at Validate File and Load Data: The task is configured to pre-compile the script, but binary code is not found. Please visit the IDE in Script Task Editor by clicking Design Script button to cause binary code to be generated.
(Microsoft.DataTransformationServices.VsIntegration)
As mentioned in the message, I opened the script IDE and added the code I need. When I close the VSA IDE, package designer displays the same error message.
The worst part of whole story is that if I close the package designer and reopen it, I find that all the code I wrote in the script task has been deleted by the package designer. This is not at all acceptable as I saved the package the and still lost all my work. I did all the coding from scratch for that task.
Please respond if anyone faced similar problem.
Thanks in advance!
Anand
PS: If any one from Microsoft is reading this, please see what you guys are coding there. Due to the buggy software you deliver, I am loosing my credibility.<P< P>
View 5 Replies
View Related
Mar 7, 2006
Hello, I have a sql 2005 server, and I am a developer, with the database on my own machine. It alwayws works for me but after some minutes the other developer cant work in the application
He got this error
Login failed for user ''. The user is not associated with a trusted SQL Server connection. [CLIENT: 192.168.1.140]
and When I see the log event after that error, it comes with another error.
SSPI handshake failed with error code 0x8009030c while establishing a connection with integrated security; the connection has been closed. [CLIENT: 192.168.1.140]
He has IIS5 and me too.
I created a user on the domain called ASPSYS with password, then in the IIS on anonymous authentication I put that user with that password, and it works, on both machines.
and in the connection string I have.
<add key="sqlconn" value="Data Source=ESTACION15;Initial Catalog=GescomDefinitiva;Integrated Security=SSPI; Trusted_Connection=true"/>
I go to the profiler, and I see that when he browses a page, the database is accesed with user ASPSYS, but when I browse a page, the database is accesed with user SElevalencia.
Thats strange.
The only way that the other developer can work again on the project is to restart the whole machine. He has windows xp profession, I have windows 2000.
If you want me to send logs please tellme
View 20 Replies
View Related
Sep 27, 2007
Hi,
I'm having a BIG problem, this is my 3rd day looking for answer !I'm trying to create a custom membership provider with MS SQL database 2005 but not the default ASPNETDB. I've changed the web.config to be as following:<connectionStrings><add name="sqlConn" connectionString="Data Source=.;Integrated Security=True;Initial Catalog=ASPNETDB;"providerName="System.Data.SqlClient" /></connectionStrings> <system.web><trace enabled="true" /><roleManager enabled="true" /><authentication mode="Forms" />
<membership defaultProvider="MySqlProvider"><providers><remove name="AspNetSqlProvider"/><add name="MySqlProvider" connectionStringName="SqlConn" type="System.Web.Security.SqlMembershipProvider" applicationName="/" /></providers></membership>
But when I try to login to the site using the login control the following error occurs:
Server Error in '/etest' Application.
Configuration Error Description: An error occurred during the processing of a configuration file required to service this request. Please review the specific error details below and modify your configuration file appropriately. Parser Error Message: The connection name 'LocalSqlServer' was not found in the applications configuration or the connection string is empty.Source Error:
Line 149: <roleManager>
Line 150: <providers>
Line 151: <add name="AspNetSqlRoleProvider" connectionStringName="LocalSqlServer" applicationName="/" type="System.Web.Security.SqlRoleProvider, System.Web, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a" />
Line 152: <add name="AspNetWindowsTokenRoleProvider" applicationName="/" type="System.Web.Security.WindowsTokenRoleProvider, System.Web, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a" />
Line 153: </providers>Source File: C:WINDOWSMicrosoft.NETFrameworkv2.0.50727Configmachine.config Line: 151
Version Information: Microsoft .NET Framework Version:2.0.50727.42; ASP.NET Version:2.0.50727.213
It is clear that this is a prblem with my Machine.Config file - since I've "worked!" on this file for a while. But when I've checked the Machine.config file I've found the LocalSqlServer connection it is talking about! .
I'm lost and I dunno what to do, can anyone help?
Here is the mahine.config in case if you need it:<connectionStrings>
<add name="LocalSqlServer" connectionString="data source=.;Integrated Security=SSPI;AttachDBFilename=|DataDirectory|aspnetdb.mdf;User Instance=true" providerName="System.Data.SqlClient" /></connectionStrings>
<system.data><DbProviderFactories>
<add name="Odbc Data Provider" invariant="System.Data.Odbc" description=".Net Framework Data Provider for Odbc" type="System.Data.Odbc.OdbcFactory, System.Data, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" /><add name="OleDb Data Provider" invariant="System.Data.OleDb" description=".Net Framework Data Provider for OleDb" type="System.Data.OleDb.OleDbFactory, System.Data, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" />
<add name="OracleClient Data Provider" invariant="System.Data.OracleClient" description=".Net Framework Data Provider for Oracle" type="System.Data.OracleClient.OracleClientFactory, System.Data.OracleClient, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" /><add name="SqlClient Data Provider" invariant="System.Data.SqlClient" description=".Net Framework Data Provider for SqlServer" type="System.Data.SqlClient.SqlClientFactory, System.Data, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" />
<add name="SQL Server CE Data Provider" invariant="Microsoft.SqlServerCe.Client" description=".NET Framework Data Provider for Microsoft SQL Server 2005 Mobile Edition" type="Microsoft.SqlServerCe.Client.SqlCeClientFactory, Microsoft.SqlServerCe.Client, Version=9.0.242.0, Culture=neutral, PublicKeyToken=89845dcd8080cc91" /></DbProviderFactories>
</system.data><system.web>
<processModel autoConfig="true" /><httpHandlers />
<membership><providers>
<add name="AspNetSqlMembershipProvider" type="System.Web.Security.SqlMembershipProvider, System.Web, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a" connectionStringName="LocalSqlServer" enablePasswordRetrieval="false" enablePasswordReset="true" requiresQuestionAndAnswer="true" applicationName="/" requiresUniqueEmail="false" passwordFormat="Hashed" maxInvalidPasswordAttempts="5" minRequiredPasswordLength="7" minRequiredNonalphanumericCharacters="1" passwordAttemptWindow="10" passwordStrengthRegularExpression="" /></providers>
</membership><profile>
<providers><add name="AspNetSqlProfileProvider" connectionStringName="LocalSqlServer" applicationName="/" type="System.Web.Profile.SqlProfileProvider, System.Web, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a" />
</providers></profile>
<roleManager><providers>
<add name="AspNetSqlRoleProvider" connectionStringName="LocalSqlServer" applicationName="/" type="System.Web.Security.SqlRoleProvider, System.Web, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a" /><add name="AspNetWindowsTokenRoleProvider" applicationName="/" type="System.Web.Security.WindowsTokenRoleProvider, System.Web, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a" />
</providers></roleManager>
</system.web>
View 8 Replies
View Related
Sep 16, 2015
I am using sqljdbc41.jar to connect with MSSQL database, it is working fine on my local machine.Where as on the remote server, same class giving me error
Login failed for user '<domain><windows loginID>'
My connection string is URL...
I am using sqljdbc41.jarĀ and on 64 bit processor , I am using following command which included path for sqljdbc_auth.dll java -Djava.library.path= C: sqljdbc_4.1enuauthx64 TestDao and error is Login failed for user '<domain><windows loginID>' why it is not picking up username passed in connection string. I have 2 machines, one is local and other is remote. on both machine I login using my domain, it is working absolutely fine on local then why the error is coming on remote machine.Both the machines are identical.
View 4 Replies
View Related
Jan 18, 2008
I have been trying to host my website on Go Daddy for about 3 weeks and I have cleared several problems but this one remains. I can get into the ASPNETDB database for doing logins , etc but I cant access my database called "PINEmgt".
To try to understand where the problem is located,I built a very simple application without login controls and put on it one Detailform accessing a single line table "Signin". I continually get the error message I got with my real app :"The connection name 'PINEMgtConnectionString2' was not found in the applications configuration or the connection string is empty. " There is only one connection string in my app -'PINEMgtConnectionString2'. When I run the app locally on my machine it works. After I move everything to Go Daddy, I get the error message and the following dump"
Line 24: </Fields>
Line 25: </aspetailsView>
Line 26: <aspqlDataSource ID="SqlDataSource1" runat="server" ConnectionString="<%$ ConnectionStringsINEMgtConnectionString2 %>"
Line 27: InsertCommand="INSERT INTO Signup(first_name, last_name, email, customer_id) VALUES (,,,)"
Line 28: SelectCommand="SELECT * FROM [Signup]"></aspqlDataSource>
This is indeed the code from my single page app.
The dump is:
[InvalidOperationException: The connection name 'PINEMgtConnectionString2' was not found in the applications configuration or the connection string is empty.]
System.Web.Compilation.ConnectionStringsExpressionBuilder.GetConnectionString(String connectionStringName) +3039085
ASP.default_aspx.__BuildControlSqlDataSource1() in d:hostinguck7scoutDefault.aspx:26
ASP.default_aspx.__BuildControlform1() in d:hostinguck7scoutDefault.aspx:10
ASP.default_aspx.__BuildControlTree(default_aspx __ctrl) in d:hostinguck7scoutDefault.aspx:1
ASP.default_aspx.FrameworkInitialize() in d:hostinguck7scoutDefault.aspx.vb:912306
System.Web.UI.Page.ProcessRequest(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint) +40
System.Web.UI.Page.ProcessRequest() +86
System.Web.UI.Page.ProcessRequestWithNoAssert(HttpContext context) +18
System.Web.UI.Page.ProcessRequest(HttpContext context) +49
ASP.default_aspx.ProcessRequest(HttpContext context) +29
System.Web.CallHandlerExecutionStep.System.Web.HttpApplication.IExecutionStep.Execute() +303
System.Web.HttpApplication.ExecuteStep(IExecutionStep step, Boolean& completedSynchronously) +64
After Googleing, asking Go Daddy for info (which they dont give) , etc for three weeks, I need serious mental help
in the form of a solution of this problem. Your help with the problem or the name of a good mental health professional in eastern N.C. (maybe both) would be appreciated.
View 10 Replies
View Related
May 30, 2008
I have seen another thread with this same problem, but the problem seemed to be a typo. I am getting an error when I try to access the web site ..
The connection name 'USASH-AS0013' was not found in the applications configuration or the connection string is empty.
However, in my web.config file I do have a connection named USASH-AS0013. Here is my web.config file (with my user/pwd hidden). Any help would be greatly appreciated.
<?xml version="1.0"?>
<!--
Note: As an alternative to hand editing this file you can use the
web admin tool to configure settings for your application. Use
the Website->Asp.Net Configuration option in Visual Studio.
A full list of settings and comments can be found in
machine.config.comments usually located in
WindowsMicrosoft.NetFrameworkv2.xConfig
-->
<configuration>
<appSettings/>
<connectionStrings>
<add name="USASH-AS0013" connectionString="Provider=SQLOLEDB;Data Source=USASH-AS0013;User ID=****;Password=*****;Initial Catalog="Smart Factory""
providerName="System.Data.OleDb" />
</connectionStrings>
<system.web>
<!--
Set compilation debug="true" to insert debugging
symbols into the compiled page. Because this
affects performance, set this value to true only
during development.
Visual Basic options:
Set strict="true" to disallow all data type conversions
where data loss can occur.
Set explicit="true" to force declaration of all variables.
-->
<compilation debug="true" strict="false" explicit="true"/>
<pages theme="MySkin" >
<namespaces>
<clear/>
<add namespace="System"/>
<add namespace="System.Collections"/>
<add namespace="System.Collections.Specialized"/>
<add namespace="System.Configuration"/>
<add namespace="System.Text"/>
<add namespace="System.Text.RegularExpressions"/>
<add namespace="System.Web"/>
<add namespace="System.Web.Caching"/>
<add namespace="System.Web.SessionState"/>
<add namespace="System.Web.Security"/>
<add namespace="System.Web.Profile"/>
<add namespace="System.Web.UI"/>
<add namespace="System.Web.UI.WebControls"/>
<add namespace="System.Web.UI.WebControls.WebParts"/>
<add namespace="System.Web.UI.HtmlControls"/>
</namespaces>
</pages>
<!--
The <authentication> section enables configuration
of the security authentication mode used by
ASP.NET to identify an incoming user.
-->
<authentication mode="Windows"/>
<!--
The <customErrors> section enables configuration
of what to do if/when an unhandled error occurs
during the execution of a request. Specifically,
it enables developers to configure html error pages
to be displayed in place of a error stack trace.
<customErrors mode="RemoteOnly" defaultRedirect="GenericErrorPage.htm">
<error statusCode="403" redirect="NoAccess.htm" />
<error statusCode="404" redirect="FileNotFound.htm" />
</customErrors>
-->
</system.web>
</configuration>
View 3 Replies
View Related
Feb 19, 2015
I have a child package where the ConnectionString property of a Connection Manager is set by a Parent Package Variable Configuration. I set up a script task that brings up a message box with the value of the ConnectionString property right before the dataflow task.
MessageBox.Show(Dts.Connections["CPU_*"].ConnectionString.ToString());When I run the parent package, the message box shows that the connection string is changing with every iteration, but in the dataflow it always draws the data from the same source.
The connection manager is an ADO.Net type, RetainSameConnection is set to False, and I've been researching this for days.
(Update 2/23/2015): To make this stranger, when I look at the diagnostic logs, they tell me that when the new connections are being opened they are using the new connection strings.
View 2 Replies
View Related
Jan 4, 2006
I came across something strange today. I was wondering I was doing something wrong.
View 7 Replies
View Related
Jul 3, 2007
This is the first time I have used SSIS, so please bear with the ignorance.
I have a super simple package that inserts x000's of rows into a temporary table. The data source is a file that the user will upload. I need to be able to tell the package what file to upload. I'm thinking the simplest thing would be to edit the connectionString property of the SourceConnectionFlatFile at runtime. Is this possible? What form should the file path be in (UNC, other)? And, are there any other considerations I should be aware of?
Thanks!
View 1 Replies
View Related
Mar 24, 2008
I am using SSIS 2005 on Windows 2003 server. Using Excel Source to dump the data for staging database.
I am getting following error while I execute it through BI studio's execute button.
Please help.
- Sachin
View 2 Replies
View Related
Mar 11, 2008
I have deployed my packages into Sql Server and I am using Configuration File. As my Data Source is Excel, I have changed the connection string during deployment with Server Path. But I am getting the following errors. Actually the File Exist in Path. May I know What is cause of the issue? Do I need to give any permission to execute the package.
SSIS Error Code DTS_E_CANNOTACQUIRECONNECTIONFROMCONNECTIONMANAGER. The AcquireConnection method call to the connection manager "Excel Connection Manager" failed with error code 0xC0202009. There may be error messages posted before this with more information on why the AcquireConnection method call failed.
component "Excel Source Service Contract Upload" (1) failed validation and returned error code 0xC020801C.
One or more component failed validation.
There were errors during task validation.
DTS_E_OLEDBERROR, Error Code: 0x80004005 Source: "MS JET DB Engine" Description : Path is not valid
View 27 Replies
View Related
Jan 14, 2008
How do I convert for example, a value comming from C# app "TextboxGBDataDeleted" to int column GBdatadeleted? I have a RangeValidator on this textbox to accept only numbers. I don't want to write C# code. I woul prefer to do this is SQL. Thank you.
My SQL update statement:
INSERT INTO KPITbl
(Lead, WRM, PTDB, PAR, PM, RequestingLOB, LOB, StartLocation, FinishLocation, Description, ProjectType, ServerName, ServerType, DCOorSTANDALONE, Responsible,
Status, RAG, StartDates, EndDates, TreeOrDomainImpacted, NumOfSites, NumOfUsers, GBdatamoved, GBdatadeleted, NumOfSrvrsAdded,
NumOfSrvrsDecommed, NumOfAppsDeployed, EUTEngineeringConsult, Comments, TimeSpend, Complexity, ECM, LastUpdated)
VALUES (@Lead,@WRM,@PTDB,@PAR,@PM,@RequestingLOB,@LOB,@StartLocation,@FinishLocation,@Description,@ProjectType,@ServerName,@ServerType,@DCOorSTANDALONE,@Responsible,@Status,@RAG,@StartDates,@EndDates,@TreeOrDomainImpacted,@NumOfSites,@NumOfUsers,@GBdatamoved,@GBdatadeleted,@NumOfSrvrsAdded,@NumOfSrvrsDecommed,@NumOfAppsDeployed,@EUTEngineeringConsult,@Comments,@TimeSpend,@Complexity,@ECM,(getdate() ) )
~~~~~~~~~~~~~~~~~~~~~~MY TABLE~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
CREATE TABLE [dbo].[KPITbl](
[TaskID] [int] IDENTITY(1,1) NOT NULL,
[Lead] [nvarchar](255) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[WRM] [nvarchar](255) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[PTDB] [nvarchar](255) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[PAR] [nvarchar](255) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[PM] [nvarchar](255) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[RequestingLOB] [nvarchar](255) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[LOB] [nvarchar](max) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[StartLocation] [nvarchar](255) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[FinishLocation] [nvarchar](255) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[Description] [nvarchar](max) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[ProjectType] [nvarchar](255) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[ServerName] [nvarchar](max) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[ServerType] [nvarchar](255) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[Responsible] [nvarchar](255) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[Status] [nvarchar](255) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[RAG] [nvarchar](255) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[StartDates] [smalldatetime] NULL,
[EndDates] [smalldatetime] NULL,
[TreeorDomainImpacted] [nvarchar](255) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[NumOfSites] [int] NULL,
[NumOfUsers] [int] NULL,
[GBdatamoved] [int] NULL,
[GBdatadeleted] [int] NULL,
[NumOfSrvrsAdded] [int] NULL,
[NumOfSrvrsDecommed] [int] NULL,
[NumOfAppsDeployed] [int] NULL,
[EUTEngineeringConsult] [nvarchar](max) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[Comments] [nvarchar](255) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[TimeSpend] [nvarchar](50) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[Complexity] [nvarchar](50) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[LastUpdated] [smalldatetime] NULL,
[DCOorSTANDALONE] [nvarchar](255) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[ECM] [nvarchar](255) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,
[StatusCompletedDate] [smalldatetime] NULL,
[StatusCancelledDate] [smalldatetime] NULL,
CONSTRAINT [PK_Sheet1a] PRIMARY KEY CLUSTERED
(
[TaskID] ASC
)WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY]
) ON [PRIMARY]
View 4 Replies
View Related
May 13, 2008
HiI have a problem to search between two dates, if I use Convert(varchar(10),ContactCreateDate,105) in a single textbow and for a single search date it is okay, but when I use the Convert(varchar(10),ContactCreateDate,105) against two textboxes it did't function.Can anybody help me ?MY codeif (TBContactSearchDateStart.Text.Length > 0 && TBContactSearchDateEnd.Text.Length > 0)
{
strWhere += " AND Convert(varchar(10),ContactCreateDate,105) BETWEEN '%" + TBContactSearchDateStart.Text + "%' AND '%" + TBContactSearchDateEnd.Text + "%'";
View 1 Replies
View Related
Feb 20, 2008
I have a RPC which gives me multiple - single record rows like
Robert|K|Half|TX|1123823|1423904 -- This is one such record that i get in 1 Column
Now I need to split the above record into 6 Fields and populate in my local DB
I know i could use any .NET Language and accomplish this. But Iam limited to using SSIS/T-SQL Proc's
Any ideas / directions?
View 6 Replies
View Related
May 15, 2007
Good Morning,
I hope that I am just missing a step in the process somewhere. I have established a string variable called DatabaseServer and another called DatabaseName. In the OLE DB connectionstring expression I have the following:
Code Snippet
"Data Source=" + @[User::DatabaseServer] + ";Initial Catalog=" + @[User::DatabaseName] + ";Provider=SQLNCLI.1;Integrated Security=SSPI;Auto Translate=False;"
My understanding is that changing the variable from SERVERA to SERVERB should repoint the connection. (Test to pre-production to production in my current promotion environment.) This should also take effect in any dataflow task using the database connection above right? When I try to repoint the server variable (and only the server variable) I am either a.)throwing errors saying the original connection cannot be found in the data flow task, or b.)the job appears to be processing fine, but the repoint did not take place and data is still flowing to the original server.
Can anyone offer suggestions as to what I am missing?
The properties values in the DB connection:
ConnectionManagerType is OLEDB
DataSourceID is blank
DelayValidation is False (Setting to true changes nothing in my test)
Expression for ConnectionString is (see above)
RetainSameConnection is False
SupportsDTCTTransactions is True (and appears to be unchangeable.)
View 7 Replies
View Related
Dec 27, 2007
Hi,
I am working on SQL Server 2005 (x64) with Windows Server 2003 (x64) operating system. I am having a major issue in SSIS. Here is the detailed explanation of the issue :
I have an EXCEL file in 2003 / 2007 version. It contains some data. I want to import the data using SSIS into SQL Server 2005 (x64) database table. I have taken "EXCEL FILE SOURCE" and "SQL Server DESTINATION". It was failed on importing data. Surprisingly it works fine in SQL Server 2005 (x32). Can you please explain why it is NOT woking on (x64) ?
Here is the error code i am getting:
[Excel Source [1]] Error: The AcquireConnection method call to the connection manager "Excel Connection Manager" failed with error code 0xC0202009.
Appreciate your time and patience !!
Thanks
View 3 Replies
View Related
Jan 26, 2008
Hello i constructed the following query in SQL management studio and it runs fine, exactly how i want it to. However when i run it in my code behind i get the error: 'Too many characters in character literal'
I desperatly need to use this query exactly how it displays in the mangement tool - why wont it work the same in my code behind?
(I am using c# in my code behind and binding the results of the query to a gridview)
Regards
"SELECT DISTINCT (dbo.AuthorList(publicationID))+ ';' + ISNULL(' Editor: '+Publication.editor, '')+ '' + ISNULL(' "'+Publication.title+'"', '')+ '' + ISNULL(' Book: "'+Publication.booktitle+'"', '')+ '' + ISNULL(' '+Publication.type, '')+ '' + ISNULL(' '+Publication.journal, '')+ '' + ISNULL(' Series: '+Publication.series+'.', '')+ '' + ISNULL(' '+Publication.school, '')+ '' + ISNULL(' '+Publication.institution, '')+ '' + ISNULL(' '+Publication.organisation, '')+ '' + ISNULL(' '+Publication.month, '')+ '' + ISNULL(' ('+convert(nvarchar, Publication.year)+')', '')+ '' + ISNULL(' '+Publication.publisher, '')+ '' + ISNULL(' '+Publication.address+'.', '')+ '' + ISNULL(' '+Publication.howpublished, '')+ '' + ISNULL(' Ed: '+convert(nvarchar, Publication.edition)+'.', '')+ '' + ISNULL(' '+Publication.note, '')+ '' + ISNULL(' Vol:'+Publication.volume+'.', '')+ '' + ISNULL(' No:'+Publication.number+'.', '')+ '' + ISNULL(' Pages:'+Publication.pages+'.', '')+ '' + ISNULL(' Chapter:'+Publication.chapter+'.', '') AS SingleColumn, Publication.publicationID FROM Publication;"
View 1 Replies
View Related
Jan 4, 2008
what is the simple way of writing code for the connection with sql server in c# .net
could any one provideme with the code for the same ism not been able to understand the funda of using class for the connection purpose
if any one knows plz let me know i am waiting
View 3 Replies
View Related
Apr 19, 2005
Below is my connection code..
Public Class clsConnect
Public Shared Function getConnection () AS SQLConnection
Dim strConn As String = "Data Source=PPS_SERVER;" & _
"Initial Catalog=eCommunity;User ID=sa;Password=pps"
Dim DBConn As SqlConnection
DBConn = New SqlConnection(strConn)
DBConn.Open()
Return DBConn
End Function
However when i run the web this error was appeared. what possibility of this problem?
SQL Server does not exist or access denied.
Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.Data.SqlClient.SqlException: SQL Server does not exist or access denied.Source Error:
Line 12: DBConn = New SqlConnection(strConn)
Line 13:
Line 14: DBConn.Open()
Line 15:
Line 16: return DBConn
View 2 Replies
View Related
May 4, 2008
can anyone please guide me how i can check whether the GPRS connection is active or not on windows mobile based application? whats the code for it? because i need to synchronize my data based on the status of GPRS connection.
thanks and regards
dhruvi
View 1 Replies
View Related
Sep 8, 2015
I am querying with a SELECT statement against an address table that has a post code column with corrupt data.
Sample record:- Northants NN4 0NB
Should be NN4 0NB
I have used the following on another column:-
LEFT(A.Addr1,CASE WHEN CHARINDEX ('(', A.Addr1) =0 THEN LEN(A.Addr1) ELSE CHARINDEX('(' ,A.Addr1) -1 END) AS 'Address 1'
but unable to correct this problem?
View 9 Replies
View Related
Jul 2, 2007
in asp usually i have code behind files those .aspx.vb file.can i make use of connection strings in there? i am not really familiar with connection strings. actually shouldn't code behind files "simulate" code being in the .aspx file themselves? i seem to not able to share variables between them?
View 2 Replies
View Related