Custom Report Manager - Multi Select Problem
Mar 10, 2008I am trying to develop a custom report manager for existing reports. I am struggling with databound dropdowns with multi-select option.
Has anyone tried it? Any input will help.
TiA
I am trying to develop a custom report manager for existing reports. I am struggling with databound dropdowns with multi-select option.
Has anyone tried it? Any input will help.
TiA
Hi,
I'm trying to deploy Reporting Services on an Internet-facing web server using a custom security extension (forms authentication). We will be putting Report Manager on the Web Server outside of the firewall, and Report Server on another machine inside the firewall. When testing the solution in a development environment with Report Manager and Report Server on the same box, the solution works fine.
When testing it using the Internet-facing environment described above, it almost works but there seems to be an issue with the authentication cookie that is generated. Here's what happens:
1. User enters credentials on UILogon.aspx and submits form.
2. In the code-behind, LogonUser() is called through a web service proxy and the authentication cookie is returned successfully. The code used here to set the cookie is the same code used in the Forms Authentication sample that ships with RS2005.
3. The user is redirected to Folder.aspx, and the request hangs for a while, and eventually kicks you back out to UILogon.aspx, as if it lost the authentication cookie. When doing a trace on the HTTP header, the cookie is still there.
Is there anything special I need to do to make the Report Server "see" the cookie when I have Report Manager and Report Server on different machines?
Any help would be much appreciated!
Mike
Hello everyone,
I created a custom assembly using C# to transform some binary data into text, and in this assembly I used one win32 dll developed by our customer to help me to do the tranformation.
The code I used to call the win32 dll is like below:
[DllImport("tdasuie.dll", EntryPoint = "AlrtLogConditionToText",
ExactSpelling = false, CharSet = CharSet.Auto, SetLastError = true)]
private static extern UInt32 AlrtLogConditionToText(Byte[] pbCondition, StringBuilder pszText, UInt32 dwSize);
I defined a C# method to call the above win32 method and return a string. Then in the report, I called this C# method to get the correct string.
In the report designer, the C# method in the custom assembly can return the correct string in the preview window. But after I deployed the report into the report server, the textbox will only display "#error" in the report manager web page.
Can anybody help me on it? Thanks a lot.
Danny
I am trying to figure out a way to toggle the visibility of attribute data based on a parameter. Specifically, I have a report that has many columns that an end-user may not want to see, depending on what they are using the report for. I know you can toggle visibilities on individual columns easily enough, however I want the user to be able to select which fields (at the attribute level) they want visible on the report up in the parameters, via a multi-value prompt.
Is this possible with reporting services 2005?
Thanks.
Hi All
New user here. I've got a report with a couple of multi-value parameters and I'm displaying the selected values on the report using = Join(Parameters!ReportingGroup.Value, ", "). This works properly.
The users now want the report to display "All" if "Select All" is chosen, rather than showing the whole list.
Can anybody help me with this? I'm thinking of using an IIF statement in my expression, but have no idea how to define the condition?
Thanks in advance
Grant
I understand that Multi-Select Parameters are converted behind the scenes to an In Clause when a report is executed. The problem that I have is that my multi-select string parameter is turned into an in claused filled with nvarchar/unicode expressions like:
Where columnName in (N'Value1', N'Value2', N'Value3'...)
This nvarchar / unicode expression takes what is already a fairly slow-performing construct and just drives it into the ground. When I capture my query with Profiler (so I can see the In Clause that is being built), I can run it in Management Studio and see the execution plan. Using N'Values' instead of just 'Value1', 'Value2','Value3' causes the query performance to drop from 40 seconds to two minutes and 40 seconds. It's horrible. How can I make it stop!!!?
Is there any way to force the query-rewriting process in Reporting Services to just use plain-old, varchar text values instead of forcing each value in the list to be converted on the fly to an Nvarchar value like this? The column from which I am pulling values for the parameter and the column that I am filtering are both just plain varchar.
Thanks,
TC
Hello,
I have several reports that use parameters that I have defined as multi-value. When I am designing the reports I see the "(Select All)" option listed first in each parm control that has the multi-value property set true. However, when the same reports are deployed to our server and viewed through Report Manager, the "(Select All)" option is missing. I need the "(Select All)" to be present.
I've seen some discussion of a service pack. Could this be the problem? What do we need to do to get our "(Select All)" back?
Thanks,
BCB
Hello,I am trying to construct a query across 5 tables but primarily 3tables. Plan, Provider, ProviderLocation are the three primary tablesthe other tables are lookup tables for values the other tables.PlanID is the primary in Plan andPlanProviderProviderLocationLookups---------------------------------------------PlanIDProviderIDProviderIDLookupTypePlanNamePlanIDProviderStatusLookupKeyRegionIDLastName...LookupValue....FirstName...Given a PlanID I want all the Providers with a ProviderStatus = 0I can get the query to work just fine if there are records but what Iwant is if there are no records then I at least want one record withthe Plan information. Here is a sample of the Query:SELECT pln.PlanName, pln.PlanID, l3.LookupValue as Region,p.ProviderID, p.SSNEIN, pl.DisplayLocationOnPCP,pl.NoDisplayDate, pl.ProviderStatus, pl.InvalidDate,l1.LookupValue as ReasonMain, l2.LookupValue as ReasonSub,pl.InvalidDataFROM Plans plnINNER JOIN Lookups l3 ON l3.LookupType = 'REGN'AND pln.RegionID = l3.Lookupkeyleft outer JOIN Provider p ON pln.PlanID = p.PlanIDleft outer JOIN ProviderLocation pl ON p.ProviderID = pl.ProviderIDleft outer JOIN Lookups l1 ON l1.LookupType = 'PLRM'AND pl.ReasonMain = l1.LookupKeyleft outer JOIN Lookups l2 ON l2.LookupType = 'PLX1'AND pl.ReasonSub = l2.LookupkeyWHERE pln.PlanID = '123456789' AND pl.ProviderStatus = 0ORDER BY p.PlanID, p.ProviderID, pl.SiteLocationNumI know the problew the ProviderStatus on the Where clause is keepingany records from being returned but I'm not good enough at this toanother select.Can anybody give me some suggestions?ThanksDavid
View 5 Replies View Related
A user was created with a limited privilege under the USERS group. Once this user loged in the Report Manager he is acting like an Admin and Content Manager, though he is not given even a browser role.
What do u think that this guy is acting like a Super User evenif he is restricted to a browser role on the Report Manager ????????????
I did all my best, but no luck so far
Hello all,
I have two mult-value parameters in my report. Both of them working with selecting one or more values. But, when I test using "(Select All)" values for both parameters , only one parameter works. The "available values" for these two parameters are both from the data set.
select distinct ProductType
from Product
order by ProductType
Any suggestion? thx
Hi All
I am using SQL Server 2005 with SP2. I have multi select parameter in the report. In SP2 reporting services gives Select All option in the drop down.
Is there any way I can remove that option from the list?
Thanks
Here's tricky one.
I have a fairly complex report that was given to me that was hard coded for single parameters. There is a dropdown for each market (created from a query in SSRS). The users have to run for each market each week.
Is there a way to use this report as a Sub-report inside a list of a master report and then use a mult-value parameter?
I want this multi-value parameter to build the values for the list and then run the "sub-report" for each value.
Essentially, I want to create a for each loop.
Any ideas?
How do I display multiple parameter values on report page from a multi-value report parameter. For example, I have a report parameter where users can select multiple attendance codes and I want them displayed at the top of the report after it's run.
Currently, only the first value is showing on the report.
Thanks.
I have a requirement where i have to display some data in the form of multi column but the main report should be in a standard one.I have tried by using sub report as multi column and used that in my main report but when i preview the report it is considering it as a normal report.Do we have any feature in SSRS to have both multi & standard report layouts in one report.
View 4 Replies View RelatedThere are several parameters on a report. One of the parameter is a multi-select enabled parameter and I suppressed the value "All" showing as one of the item in the drop down list, simply by filter out the [bha].[bha].CURRENTMEMBER.LEVEL.ORDINAL to 1, as "(Select All)" is pre-assigned to the drop list when multi-select is enabled and it is confusing to show "(Select All)" and "All" in the drop list. However I have another report which is linked to this report and the value which is required to pass to this report for this parameter is "All". Can I pass the "Select All" as a parameter from the other report? If so, how? Thanks.
View 1 Replies View RelatedI've created a very simple custom connection manager, and I followed the deployment instructions at http://msdn2.microsoft.com/en-us/library/ms345276.aspx. Basically, that was just copying the assembly to %programfiles%Microsoft SQL Server90DTSConnections, and then registering the asssembly in the gac.
However, when I open VS, right-click on the connection manager pane, and then choose new connection, my custom manager does not appear. What am I missing?
Here is the class:
using System;
using System.Collections.Generic;
using System.Text;
using Microsoft.SqlServer.Dts.Runtime;
using System.Data.SqlClient;
using System.Xml;
namespace MyCoolCompany
{
[DtsConnection(DisplayName="Sharepoint Connection Manager",
Description="Connect to Sharepoint lists",
ConnectionType="Sharepoint",
ConnectionContact="My Cool Company",
UITypeName="SPDataFlowComponent, MyCoolCompany.SharepointConnectionManagerUI")]
class SharepointConnectionManager: ConnectionManagerBase
{
}
}
Hi,
I have been working with a client on a legacy application migration to SSIS and I found SSIS to be very helpful, as this is my first project using integration services I found myself in a situation where multiple solutions can work but I cannot assess the risk of using one or the other and the effort required for the implementation.
The situation is as following, we cannot touch the input files that come from the other legacy systems so I need to get information that is packaged following the next multipart schema:
&Header with context information from the source
&BatchHeader with context information from the batch (including format N)
- Data in format N
&BatchHeader with context information from the batch (including format K)
+Data in format K
&BatchHeader with context information from the batch (including format P)
=Data in format P
Etc... Needless to say that they can come in whatever order and they need different processing depending on the format. I have been tempted to use the techniq shown in "Handling Different Row Types In The Same File" from http://www.sqlis.com/default.aspx?54.
However, there are multiple issues that I have to resolve to do that: First is how to feed the pipeline with the Data in format N and then reparse them in an easy way cause the data that comes from the other system is very wide (aprox 120 columns), so using a parsing script is by no means a viable solution (I have multiple formats to handle). So I do not see a way to treat the data without using a Custom Connection Manager. Here comes my first question: Is there anyway someone can use the already provided managers to handle an scenario like this one?
Next comes the separation, which one is the wisest thing to do: Write again that to disk in as easier format or pass along that information to the next task in memory? The volume of data is in the order of hundreds of megabytes (100 to 200), maybe half a Gigabyte in the extreme cases. How about uploading that to SQL Server and work from there?
BTW, the production servers will have 6 to 8 Gb of memory and 4 to 8 processors (more or less).
Thanks in advance.
Federico
Does anyone has code/sample/tutorial/pointer to developing custom connection manager with a custom UI. And then developing a custom task with a custom UI that can point to this custom connection manager... and passing values during runtime from UI to the custom class.
View 29 Replies View Relatedhttp://msdn2.microsoft.com/en-us/library/ms345276.aspx
does anyone know where this can be obtained? it did not come with the RTM. it does not seem to be available via download either?
a little help here!
Ok... so the microsoft documentation talks about the Sql Server Custom Connection Manager Sample all over the place. And I look to my machine after installing the samples and its not there. So I go to microsoft site and it says that the code samples are now hosted on this codeplex website. You follow the link and nothing is there for the sample. Can anyone show me exactly where I can get this sample? I find lots of people with issues trying to find and download it.. so I know i'm not the only one.
Thanks
Hi All,
I have a question, How to user the Multi value in Visual Studio Report Designer.
My dataset contains the following
Select empno,empname,basicpay,deptcd from employee where deptcd in (substring(@gdept,1,4))
Here variable gdept is the report parameter. I am passing the value.
it works fine with single value.
( the source of gdept is a another dataset to list the deparment code+name,
Example
DEP1 - COMPUTER
DEP2 - ADMIN
DEP3 - FINANCE
)
when I preview, i have a combo box to select the department.
If I choose one deparment, it works fine.
If I choose more than one department or select all I have error message
"substring function requires 3 aruguments."
what is wrong is the query
Please advise.
Cheers,
Saleem
The standard flat file connection component does not handle flat files with different column counts on different rows. Since that's the type of file I have to read, I like to create a modified version of the flat file connection manager that can do this. I have found some info in how to create a connection manager. But I can't find anything that tels me how to build one that would be recognized by the flat file source dataflow component.
So how do you build an connection manager that can used by the standard flat file source component? Anyone ever did this or knows were to get the docs?
I know my problem is also solvable by reading the row into a single column and then using a script component to split them but that is not the solution I want.
I have developed a custom report item that works fine in design and preview mode while in Visual Studio. I cannot get it to show up on my deployed reports. Here's what I have done so far:
1. Deployed the report using Visual Studio
2. updated the rsreportserver.config file with the following entry:
<ReportItems>
<ReportItem Name="PedigreeChart" Type="Uabr.Rap.PedigreeChart.PedigreeChartRenderer, Uabr.Rap.PedigreeChart" />
</ReportItems>
3. Updated the rssrvpolicy.config file with the following entry.
<CodeGroup
class="UnionCodeGroup"
version="1"
PermissionSetName="FullTrust"
Description="This code group grants Uabr.Rap.PedigreeChart.dll FUllTrust permission. ">
<IMembershipCondition
class="UrlMembershipCondition"
version="1"
Url="C:Program FilesMicrosoft SQL ServerMSSQL.3Reporting ServicesReportServerinUabr.Rap.PedigreeChart.dll" />
</CodeGroup>
I've also tried using the StrongNameMembershipCondition with no better results.
4. The dll and its dependencies are copied to the bin directory of the report server.
5. When I load a report with this custom report item on it, the report loads fine with no errors or warnings in the log file (even with verbose tracing). The area where the custom item should be is just white. It's almost like Reporting Services isn't registering the item correctly.
This is particularly frustrating because the report works fine in Visual Studio - apparently I configured that correctly. Any suggestions would be greatly appreciated. I'm stumped.
I am using RS 2000. I have a multi select parameter where I can select multiple states by separating with a comma. I am trying to figure out how to incorporate an "All" parameter.
Query:
Select [name], city, state, zipcode
From Golf inner join charlist_to_table(@State,Default)f on State = f.str
Function:
CREATE FUNCTION charlist_to_table
(@list ntext,
@delimiter nchar(1) = N',')
RETURNS @tbl Table (listpos int IDENTITY(1, 1) NOT NULL,
str varchar(4000),
nstr nvarchar(2000)) AS
BEGIN
DECLARE @pos int,
@textpos int,
@chunklen smallint,
@tmpstr nvarchar(4000),
@leftover nvarchar(4000),
@tmpval nvarchar(4000)
SET @textpos = 1
SET @leftover = ''
WHILE @textpos <= datalength(@list) / 2
BEGIN
SET @chunklen = 4000 - datalength(@leftover) / 2
SET @tmpstr = @leftover + substring(@list, @textpos, @chunklen)
SET @textpos = @textpos + @chunklen
SET @pos = charindex(@delimiter, @tmpstr)
WHILE @pos > 0
BEGIN
SET @tmpval = ltrim(rtrim(left(@tmpstr, @pos - 1)))
INSERT @tbl (str, nstr) VALUES(@tmpval, @tmpval)
SET @tmpstr = substring(@tmpstr, @pos + 1, len(@tmpstr))
SET @pos = charindex(@delimiter, @tmpstr)
END
SET @leftover = @tmpstr
END
INSERT @tbl(str, nstr) VALUES (ltrim(rtrim(@leftover)),
ltrim(rtrim(@leftover)))
RETURN
END
GO
Anyone have any ideas?
Thanks,
Deb
[One day I will come back here and answer questions, rather than only ask.]
I have a custom connection manager that returns an OleDbConnection. The only thing "custom" about the connection manager is how it determines its connection string. The object returned in AcquireConnection is an OleDbConnection.
Code:public override object AcquireConnection(object txn)
{
UpdateConnectionString();
OleDbConnection oleDbConnection = new OleDbConnection(this.connectionString);
oleDbConnection.Open();
return oleDbConnection;
}
Some of the objects within SSIS only work with an OleDbConnection, but mine is not recognized as such. Is there any way to have my connection recognized as a valid connection?
Thanks in advance.
-bms
Hi
I am running into issues with custom objects interaction with visual studio 2005.
1. Custom connection manager.
I am setting the name of the connection manager ( to standardize naming convention ) that user created, however when the CM is created, the name displayed in visual studio is still the default name even if the real name is the one i set. I have to do things like, edit it or save package - close - reopen, create another connection, ... etc in order to get it refreshed.
2. Custom Task
I am managing some variables in this custom task so that I will be adding and deleting variables in the package.
The challenge i am running into is, when I added 2 variables for example, even though the variables are successfully added to package, the Variable Window in visual studio designer will not reflect the new variables. I have to save package, close, and re-open in order for the variables to show up.
So this brings to my question - is there any way to tell Visual Studio programmatically to refresh the contents of these 2 sections, 1 is the Variable Window and the other is the panel containing the list of connection managers.
I have been searching around and found some clue about visual studio SDK but I still cannot find an exact way of doing it. Visual Studio SDK example tells you how you can access the Variable window as
framesList = new List<IVsWindowFrame>();
toolWindowNames = new List<string>();
// Get the UI Shell service
IVsUIShell uiShell = (IVsUIShell)Microsoft.VisualStudio.Shell.Package.GetGlobalService(typeof(SVsUIShell));
// Get the tool windows enumerator
IEnumWindowFrames windowEnumerator;
ErrorHandler.ThrowOnFailure(uiShell.GetToolWindowEnum(out windowEnumerator));
IVsWindowFrame[] frame = new IVsWindowFrame[1];
uint fetched = 0;
int hr = VsConstants.S_OK;
// Note that we get S_FALSE when there is no more item, so only loop while we are getting S_OK
while (hr == VsConstants.S_OK)
{
// For each tool window, add it to the list
hr = windowEnumerator.Next(1, frame, out fetched);
ErrorHandler.ThrowOnFailure(hr);
if (fetched == 1)
{
// We successfully retrieved a window frame, update our lists
string caption = (string)GetProperty(frame[0], (int)__VSFPROPID.VSFPROPID_Caption);
toolWindowNames.Add(caption);
framesList.Add(frame[0]);
}
}
But i looked up the methods for IVsWindowFrame and it does not have anything to refresh the contents of the frame.
I thought about firing events but cannot find which one to fire.
Any help on this will be greatly appreciated.
Terry
I have a very basic / stripped connection manager with only one property (SSIS 2012). It works fine in design time (you can open the connection manager editor and change the value), but in runtime it only works in 32bit mode. The runtime-validate-method does work, but if everything validates OK then in 64bit it throws an error when you run the package:
Exception deserializing the package "The package failed to load due to error 0xC0011008 "Error loading from XML. No further detailed error information can be specified for this problem because no Events object was passed where detailed error information can be stored.". This occurs when CPackage::LoadFromXML fails.
The 2 VS projects are .Net 4 class library projects with the Build Platform on "Any CPU"
I only add references to:
Microsoft.SqlServer.ManagedDTS - C:WindowsMicrosoft.NETassemblyGAC_MSILMicrosoft.SqlServer.ManagedDTSv4.0_11.0.0.0__89845dcd8080cc91
Microsoft.SqlServer.ManagedDTS.dll
Microsoft.SqlServer.Dts.Design -
[code]....
I have done the following and a domain user would not access report created a login to the SQL server to the user (this SQL Server is where data source DB is)went to site setting in Report Manager and made this use a system userright clicked on report folder and made this user in the browser roleeven checked that in the report in question, the user is already in the browser role Still the user would not access the report! "User .......... does not have required permission" is the error message I am getting.
View 6 Replies View RelatedI have written a report visual studio. The report has 10 multi-value parameters that pull data from their individual data sets within the reports. When running the report from within Visual Studio it renders fine. There are no errors reported, only a warning related to a pathname I have use to retrieve image data and display on the report.Deployment of the report is error free.When I view the report I briefly get the "Loading" splash window, but then nothing. None of the headers or static text is displayed. The results window is blank.
The report defaults all the parameter values. In trying to debug the issue I have found by reducing the number of parameter values the report will render. Once I have all the values added, the report does nothing.Below is the query being used for the report. The where clause in the query shows the parameters being used and the syntax.We are running on Windows Server 2008 R2 and SQL Server 2008 R2.
Ralph
SELECT RTRIM(a.ITEMNMBR) AS Style, RTRIM(a.ITEMDESC) AS Description, a.ITMSHNAM AS UPC, c.LOCNCODE AS Store, d.LISTPRCE AS ListPrice, a.CURRCOST AS Cost,
a.USCATVLS_1 AS [Main Category], a.USCATVLS_2 AS Market, a.USCATVLS_3 AS [Alternate Retail], a.USCATVLS_4 AS Country, b.ITEMXTRAS_1_Type AS Type,
b.ITEMXTRAS_2_Finish AS Finish, b.ITEMXTRAS_3_SubCategory AS SubCategory, b.ITEMXTRAS_4_Department AS Department,
[code]...
I am working on reports in SSRS 2008 (not R2)... There are some reports with parameters that are hidden when the report is accessed through normal URL using ReportViewer.asx..The thing is that these hidden parameters need to be visible when the report is accessed using SSRS Report Manager.
View 3 Replies View Related
Hi,
I am unable to launch report builder from the report manager from a client machine. But I am able to launch from the localhost.
Even I am able to launch report builder by clicking reportbuilder.exe on the local machine.
Please help !!
OS - Windows XP professional
SQL Reporting Services 2005.
I am getting the following error when I attempt to deploy my test report.
"Failed to Deploy Report, The user 'XXX/IUSR_XXX' has insufficient rights to perform this action."
Has anyone gotten this error before, I have tried every permission option I could with the IUSR account by adding it to each folder etc ...and still get no resolve. Anyone have a fix for this bug ?
Responses are much appreciated!!
I have few reports under different folders in Report Manager. Is there a way to set the data source for the whole folder rather than each report individually? There is also a folder where reports generate dynamically. Since the report project doesn't exist anymore, I can't set the data source through code. How can I set the data source for the whole folder?
View 7 Replies View Related