Data For Source Column 3('Col3') Is Too Large For The Specified Buffer Size.
Aug 24, 2007
Hi,
I have a problem to import xls file to sql table, using MS SQL 2000 server.
Actual main problem associated with it is xls file contain one colum having large amount of text which length is approximate 1500 characters.
I am trying to resolve it through like save xls to csv or text file then import but it also can not copy whole text of that column, like any column in xls having 995 characters then text or csv file contain 560 characater. So, it is also wrong.
Hello there,I have and small excel file, which when I try to import into SQlServer will give an error "Data for source column 4 is too large forthe specified buffer size"I have four columns in the excel file, one of the column contains alarge chunk of data so I created a table in SQL Server and changed thetype of the field to text so I could accomodate this field but stillno luck.Any suggestions as to how to go about this.Thanks in advance,Srikanth pai
I’m attempting to use DTS to import data from a Memo field in MS Access (Jet 4.0 OLE DB Provider) into a SQL Server nvarchar(4000) field. Unfortunately, I’m getting the following error message:
Error at Source for Row number 30. Errors encountered so far in this task: 1. Data for source column 2 (‘Html’) is too large for the specified buffer size.
I also get this error message when attempting to import the same data from Excel.
Per the MS Knowledgebase article located at http://support.microsoft.com/?kbid=281517, I changed the registry property indicated to 0. This modification did not help.
Per suggestions in other SQL Server forums, I moved the offending row from row number 30 to row number 1. This change only resulted in the same error message, but with the row number indicated as “Row number 1�. (Incidentally, the data in this field is greater than 255 characters in every row, so the cause described in the Knowledgebase article doesn’t seem to be my problem).
You might also like to know that the data in the Access table was exported into this table from a SQL Server nvarchar(4000) field.
Does anybody know what might trigger this error message other than the data being less than 255 characters in the first eight rows (as described in the KB article)?
I’ve hit a brick wall, so I’d appreciate any insight.Thanks in advance!
In my quest to get the Script Component as Source to work, I've come upon an error that says "The value is too large to fit in the column data area of the buffer.". Of course, I went through the futile attempt to get debugging to work. After struggling and more searching, I found that I need to run Dts.Events.FireProgress to debug in a Script Component. However, despite the fact that the script says:
I get a new error saying: Error 30451: Name 'Dts' is not declared. Its like I am using the wrong namespace, but all documentation indicates that Microsoft.SqlServer.Dts.Pipeline.Wrapper is the correct namespace. I understand that I can use System.Windows.Form.MessageBox.Show, but iterating through 100 items makes this too cumbersome. Any idea what I may be missing now?
I am getting the following error on my SSIS package. It runs a large amount of script components, and processes hundred of thousands of rows.
The exact error is: The value is too large to fit in the column data area of the buffer.
I redirect the error rows to another table. When I run just those records individually they import without error, but when run with the group of 270,000 other records it fails with that error. Can anyone point me to the cause of this issue, how to resolve, etc.
I have a variable nvarchar(1000) that I ma reading into the buffer of a data flow task in the script component script task. It gives me this error: "Script component exception.........The value is too large to fit in the column data area of the buffer."
I looked at the BufferColumn members and tried to set the maxlength to 1500. But it does not help.
I've been searching this site and the Web for info on an error message I get when importing from Access 2003 into SQL Server 2000.
'Data for Source Column 3('Col3') is too large for the specified buffer size'
A memo field in Access is larger than 255.
I have followed advice about putting the field to the first column. This doesn't work - the error just returns the new column number. In fact, I've tried just importing the first column - no good.
I am wary about making Registry changes as comments on the Web say this doesn't work either.
Hi everyone, I am using SSIS, and I got the folowing error, I am loading several CSV files in a OLE DB, Becasuse the file is finishing and the tak dont realize of the anormal termination, making an overflow. So basically what i want is to control the anormal ending of the csv file. please can anyone help me ???
I am getting the following error after replacing the '""' with '|'. The replacng is done becasue some text sting contains "" wherein the DFT was throwing an error as " The column delimiter could not foun".
[Flat File Source [8885]] Error: The column data for column "CountryId" overflowed the disk I/O buffer. [Flat File Source [8885]] Error: An error occurred while skipping data rows. [DTS.Pipeline] Error: The PrimeOutput method on component "Flat File Source" (8885) returned error code 0xC0202091. The component returned a failure code when the pipeline engine called PrimeOutput(). The meaning of the failure code is defined by the component, but the error is fatal and the pipeline stopped executing.
[DTS.Pipeline] Error: Thread "SourceThread0" has exited with error code 0xC0047038.
[DTS.Pipeline] Error: Thread "WorkThread0" received a shutdown signal and is terminating. The user requested a shutdown, or an error in another thread is causing the pipeline to shutdown.
[DTS.Pipeline] Error: Thread "WorkThread0" has exited with error code 0xC0047039.
[DTS.Pipeline] Information: Post Execute phase is beginning.
Hi i am trying to do a straight forward load from a Flatfile source , i have defined the columns according to the lenghts defined in the Data Dictionary Provided but when i am trying to run the Task i am encounterring this error
The column data for column "Column 20" overflowed the disk I/O buffer.
I tried to add another column 21 at the end and truncate or leave that column unmapped to destination but the same problem occurs for column 21 what should i do to over come this .
In case of Bad Data how to clean up the source.. Please help me with this
I encountered the following error while attempting to preview an RDL report I was developing in VS2010 using SSDT:"The size necessary to buffer the XML content exceeded the buffer quota"
We have a set of reports with same header section in all the reports. So while developing a new report i used to copy that header section to the new report with same dataset names (without any change) , but while rendering the report it is throwing error " The size necessary to buffer the XML content exceeded the buffer quota".
We can pass XML to the XML Source in a variable, but I haven't seen anywhere how much data can be passed this way? Is there a limit beyond the limits of system memory?
Also, what data types are valid for the variable? Just String?
Getting below sort of error message when running a simple select to a table from Query analyser 2000 to a SQLServer 2000 running with SP4 on different sort of times.
1) [Microsoft][ODBC SQL Server Driver][DBNETLIB]ConnectionRead (InvalidParam()).
Server: Msg 11, Level 16, State 1, Line 0
General network error. Check your network documentation.
Connection Broken
2)
[Microsoft][ODBC SQL Server Driver]Protocol error in TDS stream
[Microsoft][ODBC SQL Server Driver]TDS buffer length too large
[Microsoft][ODBC SQL Server Driver]Protocol error in TDS stream
3)
[Microsoft][ODBC SQL Server Driver]Unknown token received from SQL Server
[Microsoft][ODBC SQL Server Driver]Invalid cursor state
[Microsoft][ODBC SQL Server Driver]Unknown token received from SQL Server
Hi, I have a problem importing data from SQL Server 2000 'text' columns to SQL Server 2005 nvarchar(max) columns. I get the following error when encountering a transfer of any column that matches the above. The error is copied below,
Any help on this greatly appreciated...
ERROR : errorCode=-1071636471 description=An OLE DB error has occurred. Error code: 0x80004005.An OLE DB record is available. Source: "Microsoft SQL Native Client" Hresult: 0x80004005 Description: "Unicode data is odd byte size for column 3. Should be even byte size.". helpFile=dtsmsg.rll helpContext=0 idofInterfaceWithError={8BDFE893-E9D8-4D23-9739-DA807BCDC2AC} (Microsoft.SqlServer.DtsTransferProvider)
Hi thereAnybody know how to increase the MS SQL server buffer size?I get an error when trying so insert some pictures as OLE objects. Whentransfering to the server i get an error, that the buffer sizes needs tobe increased.RegardsRudi W.
Is it possible to change the command buffer size??
I need to export data on demand to an excel spreadsheet via a stored procedure. The only way I know how to do this is through a bulk copy command; but my query is much to big for the buffer....
I'd like to replicate an SQL Server Database to an SDF file. For Simplicity I want to use the SQL Server 2005 Management Console. The Console reports that the maximum buffer size were to small. In the comment (c# code) I can see it is set to 512. How can I increase the value in the replication assistant?
I am studying indexes and keys. I have a table that has a fixed width of data to be loaded in the first column which is parsed in a view based on data types within the fixed width specifications.
Example column A: (name phone house cost of house,zipcodecountystatecountry) -a view will later split this large varchar string based column b: is the source filename of the data load (varchar 256) ....
a. would there be a benefit of adding a clustered or nonclustered index (if so which/point in direction on why)
b. is there benefit of making one of these two columns a primary key (millions of records) or for adding a 3rd new column as a pk?
c. view: this parses the data in column a so it ends up looking more like "name phone house cost of house zipcode county state country" each having their own column.
-any pros/cons of adding indexes (if so which) to the view instead of the tables or both for once the data is parsed?
I'm trying to query a table where in the data in a cell is 65KB and when i try to do a SELECT I am unable to get the entire data from the cell.
SELECT CAST(Xml_data as XML) from TableName where ID=100 Error Message: Msg 9448, Level 16, State 1, Line 1 XML parsing: line 241, character 76, well formed check: undeclared entity
I have run the select query which returned one row. There is one column in it which has got large amount of data. I want to copy the complete content of that column(varchar(max)), but I am unable to do it. It's not the xml data. I don't want to do any conversions.
I have a virtual server (VMware ESX) with 64GB RAM running a single instance of SQL 2012 SP1. The max memory config is set to 59392 (58GB).
The Page Life Expectancy for this server has been averaging well under 10 mins for the last few days, according to our monitoring.
I have been checking the amount of data in the buffer cache periodically during the day with the below query, which seems to show that there is never more than about 10GB of data at any one time, frequently dropping below 5GB:
SELECT COUNT(*) AS BufferPages, CONVERT(decimal(10, 2), COUNT(*) / 128.0) AS BufferMB FROM sys.dm_os_buffer_descriptorsWhy would the amount of cached data be so low (and cause so much churn)?
I am aware that other things will require some of that memory (plan cache etc.) but with Max Mem of 58GB, I would expect there to be a much higher amount of actual cached data at any one time. I did the same checks on another VM with the same amount of RAM/Max Mem setting, and there was 50GB of data in the cache, with PLE measured in hours.
I need to update a large table, about 55 million rows, without filling the transaction log, in the shortest time as possible. The goal is to alter the table and change the data type for Text column from VARCHAR(7900) to NVARCHAR(MAX).
Since I cannot do it with an ALTER TABLE statement (it would fill up the transaction log) I'm thinking to:
- rename column Text in Text_OLD - add Text column of type NVARCHAR(MAX) - copy values in batches from Text_OLD to Text
The table is defined like:
create table DATATEXT( rID INTEGER NOT NULL, sID INTEGER NOT NULL, pID INTEGER NOT NULL, cID INTEGER NOT NULL, err TINYINT NOT NULL,
[Code] ....
I've thought about a stored procedure doing this but how to copy values in batch from Text_OLD to Text.
The code I would start with (doing just this part) is the following, but maybe there are more efficient ways to do it, or at least there's a better way to select @startSeq in the WHILE loop (avoiding to select a bunch of 100000 sequences and later selecting the max).
declare @startSeq timestamp declare @lastSeq timestamp select @lastSeq = MAX(sequence) from [DATATEXT] where [Text] is null select @startSeq = MIN(Sequence) FROM [DATATEXT] where [Text]is null BEGIN TRANSACTION T1 WHILE @startSeq < @lastSeq
I am running Data Flow and it fails on the OLE DB Source. Source has 13 fields in the table. One of the field is text (blob, comma delimited string - can be big) which creates a problem. This data flow runs fine with smaller amout of data. In this case Source table has 200,000 records.
The error I am getting is:
Error: 0x80070050 at Data Flow Task - SegStats, DTS.Pipeline: The file exists. Error: 0x80070050 at Data Flow Task - SegStats, DTS.Pipeline: The file exists. Error: 0xC0048019 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager could not get a temporary file name. The call to GetTempFileName failed. Error: 0xC0048019 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager could not get a temporary file name. The call to GetTempFileName failed. Error: 0xC0048013 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager could not create a temporary file on the path "C:DOCUME~1vitaaLOCALS~1Temp". The path will not be considered for temporary storage again. Error: 0xC0048013 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager could not create a temporary file on the path "C:DOCUME~1vitaaLOCALS~1Temp". The path will not be considered for temporary storage again. Error: 0x80070050 at Data Flow Task - SegStats, DTS.Pipeline: The file exists. Error: 0xC0048019 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager could not get a temporary file name. The call to GetTempFileName failed. Error: 0x80070050 at Data Flow Task - SegStats, DTS.Pipeline: The file exists. Error: 0xC0048013 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager could not create a temporary file on the path "C:DOCUME~1vitaaLOCALS~1Temp". The path will not be considered for temporary storage again. Error: 0xC0048019 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager could not get a temporary file name. The call to GetTempFileName failed. Error: 0xC0048013 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager could not create a temporary file on the path "C:DOCUME~1vitaaLOCALS~1Temp". The path will not be considered for temporary storage again. Error: 0xC0047070 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager cannot create a file to spool a long object on the directories named in the BLOBTempStoragePath property. Either an incorrect file name was provided, or there are no permissions. Error: 0xC0047070 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager cannot create a file to spool a long object on the directories named in the BLOBTempStoragePath property. Either an incorrect file name was provided, or there are no permissions. Error: 0x80004005 at Data Flow Task - SegStats, DTS.Pipeline: Unspecified error Error: 0x80004005 at Data Flow Task - SegStats, DTS.Pipeline: Unspecified error Error: 0xC0208266 at Data Flow Task - SegStats, DTS.Pipeline: Long data was retrieved for a column but cannot be added to the Data Flow task buffer. Error: 0xC0208266 at Data Flow Task - SegStats, DTS.Pipeline: Long data was retrieved for a column but cannot be added to the Data Flow task buffer. Warning: 0x80004005 at Data Flow Task - SegStats, Sort 2 [525]: Unspecified error Error: 0xC0208265 at Data Flow Task - SegStats, OLE DB Source - LS - Sensor table [1]: Failed to retrieve long data for column "DataPnts". Error: 0xC0047070 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager cannot create a file to spool a long object on the directories named in the BLOBTempStoragePath property. Either an incorrect file name was provided, or there are no permissions. Error: 0x80004005 at Data Flow Task - SegStats, DTS.Pipeline: Unspecified error Error: 0xC0208266 at Data Flow Task - SegStats, DTS.Pipeline: Long data was retrieved for a column but cannot be added to the Data Flow task buffer. Warning: 0x80004005 at Data Flow Task - SegStats, Sort 2 [525]: Unspecified error Error: 0xC0047070 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager cannot create a file to spool a long object on the directories named in the BLOBTempStoragePath property. Either an incorrect file name was provided, or there are no permissions. Error: 0xC020901C at Data Flow Task - SegStats, OLE DB Source - LS - Sensor table [1]: There was an error with output column "DataPnts" (27) on output "OLE DB Source Output" (12). The column status returned was: "DBSTATUS_UNAVAILABLE". Error: 0x80004005 at Data Flow Task - SegStats, DTS.Pipeline: Unspecified error Error: 0xC0208266 at Data Flow Task - SegStats, DTS.Pipeline: Long data was retrieved for a column but cannot be added to the Data Flow task buffer. Error: 0xC0209029 at Data Flow Task - SegStats, OLE DB Source - LS - Sensor table [1]: SSIS Error Code DTS_E_INDUCEDTRANSFORMFAILUREONERROR. The "output column "DataPnts" (27)" failed because error code 0xC0209071 occurred, and the error row disposition on "output column "DataPnts" (27)" specifies failure on error. An error occurred on the specified object of the specified component. There may be error messages posted before this with more information about the failure. Warning: 0x80004005 at Data Flow Task - SegStats, Sort 2 [525]: Unspecified error Error: 0xC0047038 at Data Flow Task - SegStats, DTS.Pipeline: SSIS Error Code DTS_E_PRIMEOUTPUTFAILED. The PrimeOutput method on component "OLE DB Source - LS - Sensor table" (1) returned error code 0xC0209029. The component returned a failure code when the pipeline engine called PrimeOutput(). The meaning of the failure code is defined by the component, but the error is fatal and the pipeline stopped executing. There may be error messages posted before this with more information about the failure. Error: 0xC0047070 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager cannot create a file to spool a long object on the directories named in the BLOBTempStoragePath property. Either an incorrect file name was provided, or there are no permissions. Error: 0x80004005 at Data Flow Task - SegStats, DTS.Pipeline: Unspecified error Error: 0xC0208266 at Data Flow Task - SegStats, DTS.Pipeline: Long data was retrieved for a column but cannot be added to the Data Flow task buffer. Warning: 0x80004005 at Data Flow Task - SegStats, Sort 2 [525]: Unspecified error Error: 0xC0047021 at Data Flow Task - SegStats, DTS.Pipeline: SSIS Error Code DTS_E_THREADFAILED. Thread "SourceThread0" has exited with error code 0xC0047038. There may be error messages posted before this with more information on why the thread has exited. Error: 0xC0047070 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager cannot create a file to spool a long object on the directories named in the BLOBTempStoragePath property. Either an incorrect file name was provided, or there are no permissions. Error: 0xC0047039 at Data Flow Task - SegStats, DTS.Pipeline: SSIS Error Code DTS_E_THREADCANCELLED. Thread "WorkThread3" received a shutdown signal and is terminating. The user requested a shutdown, or an error in another thread is causing the pipeline to shutdown. There may be error messages posted before this with more information on why the thread was cancelled. Error: 0xC0047039 at Data Flow Task - SegStats, DTS.Pipeline: SSIS Error Code DTS_E_THREADCANCELLED. Thread "WorkThread4" received a shutdown signal and is terminating. The user requested a shutdown, or an error in another thread is causing the pipeline to shutdown. There may be error messages posted before this with more information on why the thread was cancelled. Error: 0xC0047039 at Data Flow Task - SegStats, DTS.Pipeline: SSIS Error Code DTS_E_THREADCANCELLED. Thread "WorkThread2" received a shutdown signal and is terminating. The user requested a shutdown, or an error in another thread is causing the pipeline to shutdown. There may be error messages posted before this with more information on why the thread was cancelled. Error: 0x80004005 at Data Flow Task - SegStats, DTS.Pipeline: Unspecified error Error: 0xC0208266 at Data Flow Task - SegStats, DTS.Pipeline: Long data was retrieved for a column but cannot be added to the Data Flow task buffer. Error: 0xC0047021 at Data Flow Task - SegStats, DTS.Pipeline: SSIS Error Code DTS_E_THREADFAILED. Thread "WorkThread4" has exited with error code 0xC0047039. There may be error messages posted before this with more information on why the thread has exited. Error: 0xC0047021 at Data Flow Task - SegStats, DTS.Pipeline: SSIS Error Code DTS_E_THREADFAILED. Thread "WorkThread2" has exited with error code 0xC0047039. There may be error messages posted before this with more information on why the thread has exited. Warning: 0x80004005 at Data Flow Task - SegStats, Sort 2 [525]: Unspecified error Error: 0xC0047021 at Data Flow Task - SegStats, DTS.Pipeline: SSIS Error Code DTS_E_THREADFAILED. Thread "WorkThread3" has exited with error code 0xC0047039. There may be error messages posted before this with more information on why the thread has exited. Error: 0xC0047070 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager cannot create a file to spool a long object on the directories named in the BLOBTempStoragePath property. Either an incorrect file name was provided, or there are no permissions. Error: 0x80004005 at Data Flow Task - SegStats, DTS.Pipeline: Unspecified error Error: 0xC0208266 at Data Flow Task - SegStats, DTS.Pipeline: Long data was retrieved for a column but cannot be added to the Data Flow task buffer. Warning: 0x80004005 at Data Flow Task - SegStats, Sort 2 [525]: Unspecified error Error: 0xC0047070 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager cannot create a file to spool a long object on the directories named in the BLOBTempStoragePath property. Either an incorrect file name was provided, or there are no permissions. Error: 0x80004005 at Data Flow Task - SegStats, DTS.Pipeline: Unspecified error Error: 0xC0208266 at Data Flow Task - SegStats, DTS.Pipeline: Long data was retrieved for a column but cannot be added to the Data Flow task buffer. Warning: 0x80004005 at Data Flow Task - SegStats, Sort 2 [525]: Unspecified error Error: 0xC0047070 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager cannot create a file to spool a long object on the directories named in the BLOBTempStoragePath property. Either an incorrect file name was provided, or there are no permissions. Error: 0x80004005 at Data Flow Task - SegStats, DTS.Pipeline: Unspecified error Error: 0xC0208266 at Data Flow Task - SegStats, DTS.Pipeline: Long data was retrieved for a column but cannot be added to the Data Flow task buffer. Warning: 0x80004005 at Data Flow Task - SegStats, Sort 2 [525]: Unspecified error Error: 0xC0047070 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager cannot create a file to spool a long object on the directories named in the BLOBTempStoragePath property. Either an incorrect file name was provided, or there are no permissions. Error: 0x80004005 at Data Flow Task - SegStats, DTS.Pipeline: Unspecified error Error: 0xC0208266 at Data Flow Task - SegStats, DTS.Pipeline: Long data was retrieved for a column but cannot be added to the Data Flow task buffer. Warning: 0x80004005 at Data Flow Task - SegStats, Sort 2 [525]: Unspecified error Error: 0xC0047070 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager cannot create a file to spool a long object on the directories named in the BLOBTempStoragePath property. Either an incorrect file name was provided, or there are no permissions. Error: 0x80004005 at Data Flow Task - SegStats, DTS.Pipeline: Unspecified error Error: 0xC0208266 at Data Flow Task - SegStats, DTS.Pipeline: Long data was retrieved for a column but cannot be added to the Data Flow task buffer. Warning: 0x80004005 at Data Flow Task - SegStats, Sort 2 [525]: Unspecified error Error: 0xC0047070 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager cannot create a file to spool a long object on the directories named in the BLOBTempStoragePath property. Either an incorrect file name was provided, or there are no permissions. Error: 0x80004005 at Data Flow Task - SegStats, DTS.Pipeline: Unspecified error Error: 0xC0208266 at Data Flow Task - SegStats, DTS.Pipeline: Long data was retrieved for a column but cannot be added to the Data Flow task buffer. Warning: 0x80004005 at Data Flow Task - SegStats, Sort 2 [525]: Unspecified error Error: 0xC0047070 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager cannot create a file to spool a long object on the directories named in the BLOBTempStoragePath property. Either an incorrect file name was provided, or there are no permissions. Error: 0x80004005 at Data Flow Task - SegStats, DTS.Pipeline: Unspecified error Error: 0xC0208266 at Data Flow Task - SegStats, DTS.Pipeline: Long data was retrieved for a column but cannot be added to the Data Flow task buffer. Warning: 0x80004005 at Data Flow Task - SegStats, Sort 2 [525]: Unspecified error Error: 0xC0047070 at Data Flow Task - SegStats, DTS.Pipeline: The buffer manager cannot create a file to spool a long object on the directories named in the BLOBTempStoragePath property. Either an incorrect file name was provided, or there are no permissions. Error: 0x80004005 at Data Flow Task - SegStats, DTS.Pipeline: Unspecified error Error: 0xC0208266 at Data Flow Task - SegStats, DTS.Pipeline: Long data was retrieved for a column but cannot be added to the Data Flow task buffer. Warning: 0x80004005 at Data Flow Task - SegStats, Sort 2 [525]: Unspecified error Error: 0xC0047039 at Data Flow Task - SegStats, DTS.Pipeline: SSIS Error Code DTS_E_THREADCANCELLED. Thread "WorkThread0" received a shutdown signal and is terminating. The user requested a shutdown, or an error in another thread is causing the pipeline to shutdown. There may be error messages posted before this with more information on why the thread was cancelled. Error: 0xC0047021 at Data Flow Task - SegStats, DTS.Pipeline: SSIS Error Code DTS_E_THREADFAILED. Thread "WorkThread0" has exited with error code 0xC0047039. There may be error messages posted before this with more information on why the thread has exited.
I also tried to use 3 other temp paths by setting the BLOBTempStoragePath to a semi-colon separated list of paths and it did not help
We are experiencing problems inserting or updating image fields fromone table to another in SQL Server.When we do this what ever size of file we insert is doubled in sizewhen it is inserted into the destination table.This happens in insert and update queries, and if we use DTS.Any help would be greatly appreciated
I have set up transaction replication between two databases. Data from a table in the first database is replicated to the same table in another database.
The table at the publisher already has some data in it. The table at the subscriber is empty. When the replication is synchronizing, I get the following errors in the replication monitor: *The process could not bulk copy into table "dbo"."virtualdatalocations_waitingqueues". (Source: MSSQL_REPL, Error number: MSSQL_REPL20037) Get help: http://help/MSSQL_REPL20037 *Field size too large
The table looks like this: CREATE TABLE virtualdatalocations_waitingqueues ( dataid int , personid int , queueid int , CONSTRAINT FK_vw_dataid FOREIGN KEY(dataid) REFERENCES datalocations(id) ON DELETE CASCADE , CONSTRAINT FK_vw_personid FOREIGN KEY(personid) REFERENCES persons(id), CONSTRAINT FK_vw_queueid FOREIGN KEY(queueid)REFERENCES waitingqueues(id) );
It used to run fine in the past. I couldn't find any help on google or on forums.
I developed a vb app that imports csv data into an sql server db. The original text file is 36.5mb. The db after import is 230mb and the log file is 555mb. Is this normal?
Hi -- I am fairly new to SSIS development, although I am starting to appreciate it more an more, especially since I have started getting into extending the object model. Here's my question:
I have a data flow that pulls data from any number of different delimited files with different numbers of columns. I have had no problem dealing with setting up run-time file locations and file names by using the expressions of a flat file data source, and i have been able to pretty easily deal with varying file delimiters by standardizing the files before they get into the data flow. however, I have not been able to come up with a solution that will allow my data source to discover its column info at run time, and then pass that information on to the data flow task. all i really care about is being able to properly parse the individual rows into individual column data by the flat file data source because the data flow itself is able to discover the actual data that the columns hold at run-time.
i would very much appreciate any feedback from anyone on possible solutions for this.