Dynamic Changes Of AS Connection Manager Failed

Feb 15, 2007

Hi,

in my actual szenario I have to change the Server (Connection String) of Analysis Services Connection Manager from my testserver SERVER1 to my production server SERVER2. Nearly everything is easy...I set a variable to the correct servername and I used a expression to change the connection string of the connection manager during run-time. I used this technic serveral time with ole db and it works fine.

Debugging of the project shows that the variable is set correctly. The delay validation flag is set to true. When I run the package the connection establish a connection to the server which I use due designtime.

Does anybody have an idea how I can fix it?

Regards
Klaus Hoeltgen

View 2 Replies


ADVERTISEMENT

The AcquireConnection Method Call To The Connection Manager Excel Connection Manager Failed With Error Code 0xC0202009

Mar 24, 2008

I am using SSIS 2005 on Windows 2003 server. Using Excel Source to dump the data for staging database.
I am getting following error while I execute it through BI studio's execute button.

Please help.

- Sachin

View 2 Replies View Related

The AcquireConnection Method Call To The Connection Manager Excel Connection Manager Failed With Error Code 0xC0202009

Mar 11, 2008

I have deployed my packages into Sql Server and I am using Configuration File. As my Data Source is Excel, I have changed the connection string during deployment with Server Path. But I am getting the following errors. Actually the File Exist in Path. May I know What is cause of the issue? Do I need to give any permission to execute the package.



SSIS Error Code DTS_E_CANNOTACQUIRECONNECTIONFROMCONNECTIONMANAGER. The AcquireConnection method call to the connection manager "Excel Connection Manager" failed with error code 0xC0202009. There may be error messages posted before this with more information on why the AcquireConnection method call failed.



component "Excel Source Service Contract Upload" (1) failed validation and returned error code 0xC020801C.

One or more component failed validation.



There were errors during task validation.

DTS_E_OLEDBERROR, Error Code: 0x80004005 Source: "MS JET DB Engine" Description : Path is not valid


View 27 Replies View Related

Error: The AcquireConnection Method Call To The Connection Manager Excel Connection Manager Failed With Error Code 0xC0202009.

Dec 27, 2007

Hi,

I am working on SQL Server 2005 (x64) with Windows Server 2003 (x64) operating system. I am having a major issue in SSIS. Here is the detailed explanation of the issue :

I have an EXCEL file in 2003 / 2007 version. It contains some data. I want to import the data using SSIS into SQL Server 2005 (x64) database table. I have taken "EXCEL FILE SOURCE" and "SQL Server DESTINATION". It was failed on importing data. Surprisingly it works fine in SQL Server 2005 (x32). Can you please explain why it is NOT woking on (x64) ?

Here is the error code i am getting:

[Excel Source [1]] Error: The AcquireConnection method call to the connection manager "Excel Connection Manager" failed with error code 0xC0202009.

Appreciate your time and patience !!

Thanks

View 3 Replies View Related

Failed OLEDB Connection: Cannot Aquire Connection From Connection Manager

Feb 6, 2008

I have a package that uses a for loop to iterate through an unknown amount of excel files and pull their data into a table. However, there will be cases when the file is corrupted or has some sort of problem so that either the transformation will fail or the excel data source will fail with an oledb connection error.
Could anyone suggest a clean way to trap these errors? Specifically, the "Cannot Aquire Connection from Connection Manager", which is the excel connection.

Thanks,

John T

View 3 Replies View Related

The AcquireConnection Method Call To The Connection Manager &&<Connection Name&&> Failed With Error Code 0xC020200

Feb 14, 2008

Hi All,
I am getting the following error if I am using the package "Transaction Option=Required" while running through Sql Job:
The AcquireConnection method call to the connection manager "<connection name>" failed with error code 0xC0202009.

while I running the SSIS package on BI environment, I am getting the following error:
[Connection manager "<connection name>"] Error: The SSIS Runtime has failed to enlist the OLE DB connection in a distributed transaction with error 0x8004D00A "Unable to enlist in the transaction.".

I know the alternative solution is to make the "Transaction Option=Supported", but in my case I have run the whole flow in a single transaction. I came to know that this has been fixed in the service pack1(ref. to http://support.microsoft.com/kb/914375). FYI.. some time it was running successful.

I have taken all the necessary step to run the SSIS package in a distributed transaction(like the steps for MSDTC) and also created the package flow in a sequence.

I was going through the link - http://forums.microsoft.com/MSDN/ShowPost.aspx?PostID=160340&SiteID=1 but all those didn't solve my problem.

If anyone can help me it will be great. or it is a bug in SSIS?

Thanks.
Jena

View 5 Replies View Related

Login Failed;0xC0202009; Cannot Acquire Connection From Connection Manager

Dec 17, 2007

hi all,
i got the error, when i run my package after deploy into the server machine;
i can able to run that package in my local machine, if i deploy it to the server or some remote machine, its not running, and rises error messages, that says cant accquire connection from the connection manager;

the problem might be with the login name and password; i could not see any password in any of my config file, or connection manager while running the package.
how to resolve this problem?? please help me!

View 6 Replies View Related

Dynamic Connection Manager File Name

May 4, 2006

Hi There

This should be an easy one i hope.

I need to dynamically change the file name of my destination flat file connection everytime the package runs, obviously i do not want to edit the config file everytime.

I think the best way to do this is by a script taks that sets the connection manager filename property with a variable that i dynamically populate.

Is this the right way?

I just want to be sure that there is not an easier or better way to do this?

Thanx

View 6 Replies View Related

AcquireConnection Method Call To The Connection Manager Failed

Feb 13, 2008

Hi All,
I have a DB2 database on aix server. we had to move some tables to SQL Server 2005. We created individual SSIS files for each table and saved it on the desktop. When I run the package file by double clicking on it the "Execute Package Utility" dialogue box appears and I can click on the "Execute" button and everything goes fine.
But if I try to open the same package using "SQL Server Business Intelligence Devlopment Studio" or to run the same package with DTEXEC /f <Filename> , it gives me below error.
=====================================================================================
Error: SSIS Error Code DTS_E_CANNOTACQUIRECONNECTIONFROMCONNECTIONMANAGER. The AcquireConnection method call to the connection manager "SourceConnectionOLEDB" failed with error code 0xC0202009. There may be error messages posted before this with more information on why the AcquireConnection method call failed.
=====================================================================================


I am stuck on this error and need help!!!

Shailesh

View 1 Replies View Related

Error: The Connection Manager Failed To Defect From The Transaction.

Aug 3, 2007



Does anybody know what it means?
The context is: a package with a single Data Flow finishes with this error: [Connection manager "xxx"] Error: The connection manager failed to defect from the transaction.
All components inside the data flow reports a successfull green status, however the DataFlow Task remains yellow for a long time, when suddenly the package stops with the above message. Another information is that the table remains locked during package execution (a select on that table does not complete...). This is a serious issue, and I couldnt find any relevant information about that. Thanks in advance.



View 4 Replies View Related

Integration Services :: Dynamic Database For OLEDB Connection Manager In SSIS

Nov 10, 2015

I am trying to dynamically change my initial catalog in a SSIS project. Each day I get a snapshot of data from the production server. I am performing ETL on that database and loading it into my warehouse. I am trying to put something together so that each day I get the latest snapshot and if its newer then my most recent one I pass that new catalog into the connection manager. I can already run the sql script to compare the two catalogs but I can't populate the connection manager.

View 3 Replies View Related

SSIS - AcquireConnection Method Call To The Connection Manager Failed

Aug 30, 2006

Hi all,

I am facing a problem with the connection method, it says,

"[Store [10069]] Error: The AcquireConnection method call to the connection manager "Data Source Destination" failed with error code 0xC001A004. "

(Store - Look up component.)

This problem occurs only when i am using Transaction option, all the component(Look up,Destination etc) says the same error message in the Pre-Execute phase. But i can open the component and can able to see the data in preview.

And also this is not occuring in our testing environment. We have copied the same pakages in our production, the package failed stating the above. I can not simulate the same problem in my testing server.

Has anyone faced this kind of problem? please help me to solve this.

Thanks.

-Swarna.

View 17 Replies View Related

Directory Connection Failed Received On RTMT Toll Used To Monitor Call Manager

Dec 19, 2007



Hi All,

We use Cisco Call Manager 4.1(3), We use RTMT Tool to monitor our devices & now Daily once i get a error message as Directory connection failed . Monitored precanned object has value of 0., can anyone tell me what could be the excat cause or how can we troubleshoot this issue or what services should we check on our call manager to overcome this error.


Thanks & Regards
Sameer P Khakhar

View 1 Replies View Related

Help! AcquireConnection Method Call To The Connection Manager Failed With Error Code 0xC0202009

Feb 17, 2006

The package runs fine if I run it by itself. Unfortunately we want to call it from another package and when we do so it fails everytime with the following error; "AcquireConnection method call to the connection manager "BPCSF" failed with error code 0xC0202009." This package is calling an AS400 and pulling data from it into a staging environment. The task that is failing is 4th task on the list and is the 3rd task to call the AS400 environment. If I need to provide more information I would be happy to do so. Any help would be greatly appreciated. Thanks!

-Krusty

View 1 Replies View Related

The AcquireConnection Method Call To The Connection Manager Myconnection Failed With Error Code 0xC0202009.

Oct 9, 2007

I can run this package in Studio and it works fine, but when I run it from SQL Server Agent, it throws this error. Does anybody know what would cause this problem. This appears to occur during validation for the package because none of the data flow steps run. The connection being used is the same connection used in all of the data flows. If validation is done in order, then prior steps using the same connection are passing validation.

Thanks,

Steve

View 5 Replies View Related

The AcquireConnection Method Call To The Connection Manager Server.Northwind Failed With Error Code 0xC0202009;

Aug 20, 2007

Error at Text Inbound Task [SQL Server Destination [9]]: The AcquireConnection method call to the connection manager "Server.Northwind" failed with error code 0xC0202009.
Error at Text Inbound Task [DTS.Pipeline]: component "SQL Server Destination" (9) failed validation and returned error code 0xC020801C.

Please keep me posted with alternate work around(s) /solution(s).

View 1 Replies View Related

The AcquireConnection Method Call To The Connection Manager 'Blah Blah' Failed With Error Code 0xC0202009.

Apr 27, 2007

Hello everyone,



I am struggling with this error and it's starting to get to me!



I have setup a simple project with just a data flow task. In this task, it retrieves a simple record "Select * From Table1 WhereId=1". The connection is an OLE Db connection using Advantage Oledb Provider (a provider for accessing dBase). It is accessing a Novell network drive. I have setup the package to both "EncryptSensitiveWithPassword" and "DontSaveSensitive". Both times i have received this error.



The funny thing is, when I set the package to "EncryptSensitiveWithPassword" and I setup a job to run the package, it never asks me for the password even though I set one up! I have a previous package (few months ago I made) that accessed the same database on the same Network drive and it works! It also asks me for a password when I try to modify or run the package (b/c I set it to "EncryptW/Password").



Can anyone give any light into this problem?



Thansk for all your support,



Adrian



View 1 Replies View Related

The Connection Type OLEDB Specified For Connection Manager Is Not Recognized As A Valid Connection Manager Type - Why?

Mar 17, 2008

Greetings,

I have an SSIS package that I need to modify. It was developed in Visual Studio 2005 and runs faithfully in production on SQL Server 2005. Suddenly, I can't open the package on my own workstation. I see a big red "X" image and a message stating "Microsoft Visual Studio is unable to load this document." The real reason the document can't be loaded appears to be:

Error loading DataWarehouseLoader.dtsx: The connection type "OLEDB" specified for connection manager "Warehouse Logging OLE DB" is not recognized as a valid connection manager type. This error is returned when an attempt is made to create a connection manager for an unknown connection type. Check the spelling in the connection type name.


Does anyone know what causes this and what I can do? The package has been in production for 9 months and I've never seen this problem before.

Thanks,
BCB

View 10 Replies View Related

Sql Connection Failed Because Of Connection Failure Login Failed For User 'SW8/Guest

May 16, 2007

Sir i am trying to connect sql from my LAN to my networked computers but whenever i tried to register it through Enterprise manager i get following "SQL Server registration failed because of the conection failure displayed below.Do you wish to Register anyway? Login failed for user 'SW17/Guest'

where SW17/ is my another computer name...
i have checked tcp and named pipes
and confirm username for sql authentication too
please help me as i being late submit my project

View 3 Replies View Related

Entreprise Manager Error Message: [Microsoft][ODBC SQL ServerDriver][SQL Server]Login Failed For User '#####'. The User Is Not Associatedwith A Trusted SQL Server Connection.(28000,18452)

Dec 12, 2007

Can anyone give a quick description of the meaning of this message andwhat needs to be done to get a connection.I'm running DBArtisan with SQLServer 2000 client SP4 installed.I also get the same message with MS Enterprise Manager so this iscoming out of the actual ODBC connection attempt.Thanks in advance!

View 1 Replies View Related

Fix For Transmission_status Message Connection Handshake Failed [...] The Logon Attempt Failed

Mar 30, 2007

Full message:

Connection handshake failed. An OS call failed: (8009030c) 0x8009030c(The logon attempt failed). State 66



Under these conditions, setting trustworthy on on the sending and receiving databases will solve this issue

1) Communicating between multiple instances

2) Using Kerberos security (NT Authentication, i.e. not certificates)

View 5 Replies View Related

SSIS Project Failing To Run Even Though I Verified Remote Sybase Connection Via Connection Manager

Apr 7, 2008



When running the project in debug mode or non-debug mode, I get the following error from MS Visual Studio:

TITLE: Package Validation Error
------------------------------
Package Validation Error
------------------------------
ADDITIONAL INFORMATION:
Error at Package [Connection manager "SYBASE_CONNECTION"]: The connection manager failed to defect from the transaction.
(Microsoft.DataTransformationServices.VsIntegration)
------------------------------
BUTTONS:
OK
------------------------------

Any ideas???

View 8 Replies View Related

Integration Services :: Unable To Get Managed Connection From Connection Manager Runtime

Apr 15, 2015

I use SQL Server 2012 and visual studio 2010.I created SSIS Project with task "Execute Package". Control flow view as: Package1 (execute package) -> Package2 (data flow).Data flow in Package2 view as: ADO.NET source -> ADO.NET destination.

When I started Package2, it's work. I havn't errors.But when I started Package 1 I have error "Unable to get managed connection from the Connection Manager runtime". In execution log I see that ADO.NET source produced this error on verification stage. Package failed on verification stage, not on execution stage.Why when I started Package 2 it work, but when I started Package1 (and Package1 started Package2) it failed?

View 14 Replies View Related

Rounding Error: Between Flat File Connection Manager Source &&amp; OLE DB Connection Destination (SQL Server 2005)

Jun 22, 2006

I have a Rounding error: Between flat file connection manager Source & OLE DB Connection Destination (SQL Server 2005) in my Dataflow.

File looks like this lets call column names Col A,B,C,D

70410000 RD1 1223631.92 196042.42
70329000 ICD 11025.84 3353.88
71167300 COL 104270.59 24676.96

flat file connection manager settings: first row Column names then Advanced tab Col A float , Col B float , Col C string ,Col D float ,

OLE DB Connection Destination (SQL Server 2005)

CREATE TABLE [dbo].[PT_CUST_ABR](

[PARTY_NO] [float] NULL,

[PARTY_NAME] [varchar](75) COLLATE SQL_Latin1_General_CP1_CI_AS NULL,

[TELECOMABR] [float] NULL,

[GENIABR] [float] NULL,



Problem: ColA (Source) Rounding error to PARTY_NO (Destination)
I have a field of text of in a flat file that the flat file connection manager Source picks up correctly €œ70000893€?
However when it gets the OLE DB Connection Destination the data has changed to 70000896. That€™s before its even Written to the database.
The only clue that something is wrong in the middle is the great Data viewer shows the number as 7.000009E+07
Other clues looking at the data it appears there is a rounding error on only the number that dont end in 00
ColA (Source) PARTY_NO (Destination)
71167300 71167296
70329000 70329000
70410000 70410000
Any ideas people?
Thanks in advance
Dave



View 3 Replies View Related

Failed To Acquire Connection / The AcquireConnection Method Failed

Nov 11, 2005

I am running the Sept CTP.  I have created a SSIS package that pulls data from a text file and inserts into a database.  When I run the package on the DB server it runs fine.  I have moved the package the the web server (we are attempting to kick off the package from a web site) and we get connections errors. We are running the package using dtexec from the command line.

View 7 Replies View Related

SQL Server 2008 :: Connection Manager Not Using Connection String Value

Feb 19, 2015

I have a child package where the ConnectionString property of a Connection Manager is set by a Parent Package Variable Configuration. I set up a script task that brings up a message box with the value of the ConnectionString property right before the dataflow task.

MessageBox.Show(Dts.Connections["CPU_*"].ConnectionString.ToString());When I run the parent package, the message box shows that the connection string is changing with every iteration, but in the dataflow it always draws the data from the same source.

The connection manager is an ADO.Net type, RetainSameConnection is set to False, and I've been researching this for days.

(Update 2/23/2015): To make this stranger, when I look at the diagnostic logs, they tell me that when the new connections are being opened they are using the new connection strings.

View 2 Replies View Related

Connection Manager Not Showing New Connection From Data Source...

Mar 30, 2007

Hello,

I've created a SSIS Solution and have created Data Sources. I have two packages. One was created before the Data Sources, and one was created after. The package that was created after is using connections from the Data Sources. I want to change the package before the Data Soruces were created to use them, but when I right click in the Connection Managers pane "New Connection From Data Source.." is not an option.

Did I not add it to the Solution properly?

How do I get it to show?

Did I not refresh something?

Please provide the how if you figure it out.

Thanks

View 4 Replies View Related

Cannot Acquire A Managed Connection From The Run-time Connection Manager

Jul 26, 2006

How would one go about using an ODBC connection with SSIS. I'm trying to ETL some Sybase ASE data, but I get the error when I try it:

"cannot acquire a managed connection from the run-time connection manager"



This wasn't any help:

http://forums.microsoft.com/MSDN/ShowPost.aspx?PostID=169777&SiteID=1



View 1 Replies View Related

Edit Connection Manager Connection String At Runtime With C#

Jul 3, 2007

This is the first time I have used SSIS, so please bear with the ignorance.



I have a super simple package that inserts x000's of rows into a temporary table. The data source is a file that the user will upload. I need to be able to tell the package what file to upload. I'm thinking the simplest thing would be to edit the connectionString property of the SourceConnectionFlatFile at runtime. Is this possible? What form should the file path be in (UNC, other)? And, are there any other considerations I should be aware of?



Thanks!

View 1 Replies View Related

Using Oledb Connection From Connection Manager In Script Task

Aug 9, 2006

Is there anyone who tried to use a connection from connection manager to create a new connection in a script task? Including the password?

Now i passed the connection to the script task and called it in the vb script but then the password is not passed into the connect string.

Im searching for an example that works with passing the password in the connectstring?



Any help will be greatfull.


View 1 Replies View Related

Making The Connection In A Connection Manager Retry

Jan 16, 2008

Is there a way by which we can make the Connection in the connection manager retry for a certain amount of time?

I have a DataFlow Task which uses a OLE Source which is connected to a database. there are time when the connection to the database is not available due to some transport level error. so i wanted the connection manger to make a couple of tries before giving up and saying that it was not able to connect and it timed out..

i have the Connect TimeOut and the General Timeout properties set to 0, but is there a way to retry?

Thanks for any help in advance

View 1 Replies View Related

OlE DB Source - Cannot Acquire Connection From Connection Manager

Jul 13, 2007

My source files are in C:Process folder. File names are in the format proc*.csv

I am using foreach loop container to iterate over the files in folder "C:Process"

I have a user variable "filename"



The order of my tasks

ForEach - Data Flow task - File System Task



In Data Flow task, I have ole db source which should take the dynamic filename from user variable "filename". whats happening is when i give fixed filename, without foreach loop container the package is working fine.

with dynamic filename, I am not able to run the package because of ole db source Error - cannot aquire connection from connection manager.



Thanks for u'r help.

View 9 Replies View Related

How To Re-use Connection Manager ADO.NET Connection In A Script Task?

Jun 1, 2007

I'm currently using:

Dts.Connections.Item("myADO.NET connection").AcquireConnection(Nothing)Dim conn As New SqlClient.SqlConnection(Dts.Connections.Item("myADO.NET connection").ConnectionString)
conn.Open()

This seems silly, in that I'm not really using the same connection, but using the connection string of a connection that already exists. And, for my purposes, it's not working currently, because I've switched from Windows Authentication to SQL Auth... and the password isn't coming over in the ConnectionString property.How do I re-use the exact same ADO.NET connection I have in my connection manager in a script task? That's the recommended way to go, right?

View 3 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved