Error OutPut In Custom Source Component
May 11, 2006
For the Custome source Component ErrorOutput, should I go for asynchronous / synchronous Output.
If i go for synchronous output
// Create the error output.
IDTSOutput90 errorOutput = ComponentMetaData.OutputCollection.New();
errorOutput.IsErrorOut = true;
errorOutput.Name = "ErrorOutput";
errorOutput.SynchronousInputID = What Id is required here;
errorOutput.ExclusionGroup = 1;
Is it the IDTSOutput90 InPut.ID / OutPut.ID which should be assigned.
Thanks Regards
Anil
View 5 Replies
ADVERTISEMENT
Dec 6, 2007
Hi all,
I saw a couple of other posts here on this topic, but none quite got to my issue.
I'm trying to add error output to a custom source component (not a script, a custom component). The samples all seem to deal with transform components, and my issues seem to be unique to source components.
I have the following code related to error handling ...
Public Overloads Overrides Sub ProvideComponentProperties()
...
Dim output As IDTSOutput90 = ComponentMetaData.OutputCollection.New
output.Name = OUTPUTCOLUMNNAME
output.ExternalMetadataColumnCollection.IsUsed = True
ComponentMetaData.UsesDispositions = True
output.ErrorRowDisposition = DTSRowDisposition.RD_NotUsed
output.ErrorOrTruncationOperation = "Something got truncated or blew up"
Dim errorOutput As IDTSOutput90 = ComponentMetaData.OutputCollection.New
errorOutput.Name = ERRORCOLUMNNAME
errorOutput.IsErrorOut = True
...
End Sub
Public Overloads Overrides Sub ReinitializeMetaData()
Dim output As IDTSOutput90 = ComponentMetaData.OutputCollection(OUTPUTCOLUMNNAME)
Dim outColumn As IDTSOutputColumn90 = output.OutputColumnCollection.New
outColumn.Name = strName
outColumn.SetDataTypeProperties(DataType.DT_I4, 0, 0, 0, 0)
Dim metadataColumn As IDTSExternalMetadataColumn90 = output.ExternalMetadataColumnCollection.New
metadataColumn.Name = outColumn.Name
metadataColumn.DataType = outColumn.DataType
metadataColumn.Precision = outColumn.Precision
metadataColumn.Length = outColumn.Length
metadataColumn.Scale = outColumn.Scale
metadataColumn.CodePage = outColumn.CodePage
outColumn.ExternalMetadataColumnID = metadataColumn.ID
outColumn.ErrorRowDisposition = DTSRowDisposition.RD_NotUsed
outColumn.ErrorOrTruncationOperation = "Something Truncated!"
outColumn.TruncationRowDisposition = DTSRowDisposition.RD_NotUsed
Dim errorOutput As IDTSOutput90 = ComponentMetaData.OutputCollection(ERRORCOLUMNNAME)
Dim errorColumn As IDTSOutputColumn90 = errorOutput.OutputColumnCollection.New
errorColumn.Name = outColumn.Name
errorColumn.SetDataTypeProperties(DataType.DT_I4, 0, 0, 0, 0)
...
End Sub
The confusions I have are:
a) the stock advanced properties editor (I haven't provided a custom one) doesn't seem to "realize" that I have an error output, so provides no method to configure. I am believing it would need to know which Output columns can have their error/truncation redirected. I'd have thought setting ErrorRowDisposition on my output column would have been enough to trigger this ??
b) since I don't have any means of configuring, not surprisingly, when I try to connect my error output, designer complains that, "Ths error output cannot receive any error rows. This occurs for several reasons: Input columns or output columns are not yet defined. Error handling is not supported by the component. Error handling is not configured for the component."
c) UsesDispoistions would seem to be appropriate only for a transform component
Thanks for reading, and appreciate any help or pointers.
Bill
View 5 Replies
View Related
Aug 17, 2015
I'm writing a custom source component that reads data from a SharePoint list with dynamic mapping to output columns. It's my first custom component and it's based on several samples and tutorials from Internet
Output columns are not created by the component itself, they must be added by user at design time. The component makes dynamically an association between SharePoint fields and available output columns at run-time (based on an mapping table).
I made a very basic skeleton and I encounter a problem when I add a column to output: it has no datatype and when I try to set one I have an the error Property value is not valid, The component xxxxxx does not allow setting output column datatype properties.
Imports System
Imports Microsoft.SqlServer.Dts.Pipeline
Imports Microsoft.SqlServer.Dts.Pipeline.Wrapper
Imports Microsoft.SqlServer.Dts.Runtime.Wrapper
<DtsPipelineComponent(ComponentType:=ComponentType.SourceAdapter,
DisplayName:="SharePoint Dynamic Assoc List Source",
[Code] ....
View 4 Replies
View Related
Apr 21, 2006
1) We are writing a custome Source component for Oracle with OCI calls, Could some one please let me know how to Enable Error Handling for the Same,
2) Is it possible to write Custome Error Handeling Component for SSIS? if yes could you please help me on how to write it.
Thanks in advance.
View 1 Replies
View Related
May 10, 2006
Hi
in the acquireconnection method Using the below statment I can get a connection Object
oledbConnection = cmado.AcquireConnection(transaction) as OleDbConnection;
from the connection object I can get the connectionstring from the object by calling
oledbConnection.connectionstring() property which will have all the details like DataBase, UserName & other Inofrmation but there is no password Info.
How to get the password Information, I need that information since I will use that info to make OCI calls to fetch the data from the Oracle database in m,y custome source component.
any help is much appriciated
thanks in advance.
View 10 Replies
View Related
Mar 23, 2006
Hi,I have developed a custom source component to get data from a generic odbc connection with some special caracteristics.
The component works fine by getting and mapping the output fields etc...
The only two problems existing are that when i run the task it says that the data flow has no components inside... how is this possible since i have my source mapped to a flat file inside that data flow?
This is the error:
SSIS package "BVEIT000D.dtsx" starting.
Warning: 0x80047034 at BVEIT000D_<EMPRESA> TXT, DTS.Pipeline: The DataFlow task has no components. Add components or remove the task.
Information: 0x4004300C at BVEIT000D_<EMPRESA> TXT, DTS.Pipeline: Execute phase is beginning.
SSIS package "BVEIT000D.dtsx" finished: Success.
The other problem is that if i want to <ignore> a certain source column the component already shows me an error saying that the no column with ID 0 was found...
Any one with experience in creating custom components?
Regards,
View 6 Replies
View Related
Mar 27, 2007
Hi Guys,
I created a SSIS custom component, transformation (Asynchronous) with one Input collection and 2 output collections.
The SSIS Package which includes the Component I created works well in the Business Intelligence Studio, but when the same Package is run in the 'Execute Package utility' It fails to run. ( when you Double click on the dtsx file)
The cause of the failiure is
public override void PrimeOutput(int outputs, int[] outputIDs, PipelineBuffer[] buffers)
method receives only one output buffer when executed using the 'Execute Package Utility' { outputs = 1 , buffer.Length = 1 } ( when executed in the BI studio, the method receives parameters of both the output buffers that I expect { outputs = 2 , buffer.Length = 2 } )
The property ComponentMetaData.OutputCollection.Count = 2 as well. Yet the PrimeOutput method provides only 1 buffer.
The Validation Succeeds on both instances, which I assume means that Meta Data is Provided Properly.
What would be the reason for the same pakage to run in 2 different ways like this,
What might I have missed out to do, to make the package run in different ways on 'Business Intelligence Studio' and 'Execute Package Utility'
Thanks a lot
Below are some of the lines from the ProvideComonentProperties Method which deals with the output Collection, Isn't this sufficient for the PrimeOutput to provide 2 output buffers?
ProvideComponentProperties()
public override void ProvideComponentProperties()
{
RemoveAllInputsOutputsAndCustomProperties();
base.RemoveAllInputsOutputsAndCustomProperties();
base.ProvideComponentProperties();
//other function calls
IDTSOutput90 output1 = ComponentMetaData.OutputCollection[0];
output1.Name = "Output1";
output1.Description = ".......................";
extracted.SynchronousInputID =0;
IDTSOutput90 output2 = ComponentMetaData.OutputCollection.New();
output2.Name = "Output2";
output2.Description = "..........................";
output2.SynchronousInputID = 0;
//other function calls
}
View 3 Replies
View Related
Jan 15, 2008
I would like to write a custom data source component for SSIS. I was wondering if there are any tutorials / examples for this that are available.
Thanks
View 1 Replies
View Related
Jun 26, 2006
Would anyone happen to have any pointers or know of any good code examples to either programmatically change the type of an input column when it is passed through the component, or add a new column to the output? I am extracting data from an Oracle database which is in Julian date format (represented within SSIS as a DT_NUMERIC column) and I need to to either transform the input column holding it into a date column, or to dynamically add a new output column holding the transformed data.
Many thanks
View 1 Replies
View Related
Apr 17, 2006
I'm having a tad bit of trouble getting output from an asynchronous component that I've written and am looking for some insight.
This component takes in a name string passed from upstream and parses the name components into standardized output fields. I'm using an asynchronous component because if the name string contains two names ("Fred & Wilma Flintstone") I'm outputting one row for Fred and one for Wilma. I've gotten it to run and with debugging have observed what appeared to me to be proper execution, but zero rows are flowing out of it.
In my ProvideComponentProperties method, I add the three fields and there associated metadata to the OutputColumnCollection. Is this method where this should occur? It's before the PrimeOutput method, so I didn't know if I should be creating the output columns in ProcessInput (i.e., after the output buffer is provided by PrimeOutput.)
In ProcessInput, I'm using AddRow for each input row and another if it contains a second name, setting the value for each index using the buffer's SetString method, to no avail. I can observe it to this point, but then don't know what's in that output buffer (if I'm using the wrong buffer index value, etc)
Thanks.
View 3 Replies
View Related
Aug 28, 2007
I'm trying to create a fairly simple custom transform component (because I've read that's the easiest one to create) which will take one column from a flat file source and based on the first row create the output columns.
I'm actually trying to write a component that will solve the now well known problem with parsing CSV files in SSIS. I have a lot of source files and all have many columns so a component that can read in the first line from the CSV file and create the output columns automatically will save me lots of time when migrating the old DTS packages.
I have the basic component set up but I'm stuck when trying to override the OnInputPathAttached method because I don't know how to use the inputID to get the first line from the input (the buffer).
Are there any good examples for creating output columns dynamically based on the input buffer?
Should I just give up on on the transform and create a custom source component instead?
View 5 Replies
View Related
Mar 13, 2007
Hi,
I have implemented a custom source component that can be used as the data source in the Data Flow task.
I have also created a custom UI for this component by using the IDtsComponentUI .
But my component does not have the capability of setting the custom properties via the DTS Variables using the Expression Builder.
I have looked around for samples on how to do this, but I can only find samples of how to do this for custom Control Tasks, i.e. IDtsTaskUI.
My question is, How can implement the Expression Builder in my custom Source component + custom Source UI. Or do you know of any samples which I can look at.
Thank you,
Jameel.
View 1 Replies
View Related
Oct 26, 2007
Hello,
I have a package that has a data lfow task. this task imports data from a db2 database (using the IBM Ole DB provider fro db2) and adds it to sql server database table. This package was created on the server. then though version control (using TFS source control) I check out the package on my local machine. and when I open the package I get the foll 3 errors.
Error 1 Validation error. Import Account Num from BMGP_BDR: DTS.Pipeline: The component metadata for "component "DataReader Source" (1113)" could not be upgraded to the newer version of the component. The PerformUpgrade method failed.
Error 2 Error loading BMAG Download Xref Tables - bmag.dtsx: Microsoft.SqlServer.Dts.Pipeline.ComponentVersionMismatchException: The version of component "DataReader Source" (1113) is not compatible with this version of the DataFlow. [[The version or pipeline version or both for the specified component is higher than the current version. This package was probably created on a new version of DTS or the component than is installed on the current PC.]] at Microsoft.SqlServer.Dts.Pipeline.ManagedComponentHost.HostCheckAndPerformUpgrade(IDTSManagedComponentWrapper90 wrapper, Int32 lPipelineVersion)
Error 3 Error loading BMAG Download Xref Tables - bmag.dtsx: The component metadata for "component "DataReader Source" (1113)" could not be upgraded to the newer version of the component. The PerformUpgrade method failed.
Please advice.
Thank you.
View 7 Replies
View Related
Jan 23, 2007
Hi,
I have a package which reads an Access file from a folder. My connection manager to this file is .NET providers for OledbMicrosoft Jet 4.0 OLE DB Provider.
Package works from my computer. But when I execute it on the server as a SQL Agent job, I get
The component metadata for "component "DataReader Source" (1) could not be upgraded to the newer version of the component. The PerformUpgrade method failed.
I copied the mdb file to a folder on the server which my packages have no problem reading data from.
My packages run under the same domain account as defined in proxies.
Appreciate a help.
Gulden
View 4 Replies
View Related
May 28, 2008
I have set a validation error when changing a property in the advanced editor. Unfortunately this validation error is only displayed when you change tabs or press the ok button in the editor.
I have tried calling the validate method within the setcomponentproperty method but the error only show up when ok button is pressed or tab in editor.
I don't want to throw an exception, is there any way you can show a validation error immediately once the user has clicked away / entered / clicked to another property field after entering a property value in the advanced editor that is incorrect.
Thanks
View 1 Replies
View Related
Aug 13, 2007
Hi all
I'm into a project which uses a lot of views for joining 2 or more tables. Using the MERGE component in SSIS will be a huge effort coz it only has 2 inputs and I gotta SORT the input too.
Isnt it possible to have a VIEW like component that joins more than 2 tables and DOESNT need sorting??
(I've thought about creating views in database engine but it breaks my data floe in SSIS and is'nt a practical solution)
View 4 Replies
View Related
Apr 16, 2007
Hi,
I have created a program that imports a csv into the sql server. but during that import I need to track all the errors that occured for some malformed rows. I think I need to use the error output collection of the dataflow components to track the errors. I figured out that every dataflow component has a error output collection along with the data output collection. I want to write those error outputs into a separete database. So, I have created a SQL server data destination component and created a path between derived columns error output and it input collection. But it is not working as expected. can any body help on this?
or can anyone give me any example how to use/handle error output collection in SSIS?
I will appreciate all kind of suggestions.
thanks
View 2 Replies
View Related
Feb 14, 2006
Hi,
I have a 2 custom components - source and destination.
I want to create an error output for each, to allow the users of my component to handle errors the way they choose.
I only found a property in IDTSOuptut90 named isErrorOut - a boolean property indicating whether this output is an error output or not.
Does anyone have additional documentation / articles / code samples regarding how to really populate the rows in the error output?
Thanks
View 1 Replies
View Related
Aug 21, 2007
Can someone please point me to one or more examples of a Source component that has two or more outputs?
I wrote a source, which works with a single output, but after adding a second output, I see no rows there. I've single-stepped the code in the debugger, and it looks like it should be adding rows to the second output, but the downstream component never sees any.
Thanks.
View 7 Replies
View Related
Mar 30, 2006
I am writing a custom dataflow transformation component and I need to get the name of the preceeding component.
I have been trying to find a way to get a reference to the Package object, MainPipe object or IDTSPath90 object (connecting to the IDTSInput90 of my component) from my component because I think from there I can get to the information I want.
Does anyone have any suggestions?
TIA . . . Ed
View 7 Replies
View Related
Aug 14, 2007
Hi,
I've created a Custom Data Flow Component and added some Custom Properties.
I want the user to set the contents using an expression. I did some research and come up with the folowing:
Code Snippet
IDTSCustomProperty90 SourceTableProperty = ComponentMetaData.CustomPropertyCollection.New();
SourceTableProperty.ExpressionType = DTSCustomPropertyExpressionType.CPET_NOTIFY;
SourceTableProperty.Name = "SourceTable";
But it doesn't work, if I enter @[System:ackageName] in the field. It comes out "@[System:ackageName]" instead of the actual package name.
I'm also unable to find how I can tell the designer to show the Expression editor. I would like to see the elipses (...) next to my field.
Any help would be greatly appreciated!
Thank you
View 6 Replies
View Related
Apr 2, 2007
Hi,
I'm trying to enable Expression for a custom property in my custom data flow component.
Here is the code I wrote to declare the custom property:
public override void ProvideComponentProperties()
{
ComponentMetaData.RuntimeConnectionCollection.RemoveAll();
RemoveAllInputsOutputsAndCustomProperties();
IDTSCustomProperty90 prop = ComponentMetaData.CustomPropertyCollection.New();
prop.Name = "MyProperty";
prop.Description = "My property description";
prop.Value = string.Empty;
prop.ExpressionType = DTSCustomPropertyExpressionType.CPET_NOTIFY;
...
}
In design mode, I can assign an expression to my custom property, but it get evaluated in design mode and not in runtime
Here is my expression (a file name based on a date contained in a user variable):
"DB" + (DT_WSTR, 4)YEAR( @[User::varCurrentDate] ) + RIGHT( "0" + (DT_WSTR, 2)MONTH( @[User::varCurrentDate] ), 2 ) + "\" + (DT_WSTR, 4)YEAR( @[User::varCurrentDate] ) + RIGHT( "0" + (DT_WSTR, 2)MONTH( @[User::varCurrentDate] ), 2 ) + ".VER"
@[User::varCurrentDate] is a DateTime variable and is assign to 0 at design time
So the expression is evaluated as: "DB189912189912.VER".
My package contains 2 data flow.
At runtime,
The first one is responsible to set a valid date in @[User::varCurrentDate] variable. (the date is 2007-01-15)
The second one contains my custom data flow component with my custom property that was set to an expression at design time
When my component get executed, my custom property value is still "DB189912189912.VER" and I expected "DB200701200701.VER"
Any idea ?
View 5 Replies
View Related
Jan 13, 2006
Synopsis:
Attempting to create a data flow task to copy data from AS/400 (DB2) to SQL2005, using an existing System DSN ODBC connection defined on the SQL2005 host.
Problem:
When adding the DataReader Source component to the package, I cannot assign the Connection Manager. Designer issues the error message:
"The runtime connection manager with the ID "" cannot be found. Verify that the connection manager collection has a connection manager with that ID."
Editing the DataReaderSrc component shows only one row under the Connection Managers tab:
Name=IDbConnection
Connection Manager=blank
Description=Managed connection manager
The datareadersrc component editor displays the warning message: "Not all connection managers have been set. Set all connection managers.". Clicking the Refresh button causes the error message to be displayed "The runtime connection manager with the ID "" cannot be found. Verify that the connection manager collection has a connection manager with that ID."
I am prevented from assigning my Connection Manager object the DataReaderSrc.
The package already contains one Connect Manager object:
Provider: .Net Providers/Odbc Data Provider
System DSN
Test Connection operation succeeds
Any help would be appreciated.
Fraser.
View 3 Replies
View Related
May 14, 2008
i have a weird situation here, i tried to load a unicode file with a flat file source component, one of file lines has data like any other line but also contains the character "ÿ" which i can't see or find it and replace it with empty string, the source component parses the line correctly but if there is a data type error in this line, the error output for that line gives me this character "ÿ" instead of the original line.
simply, the error output of flat file source component fail to get the original line when the line contains hidden "ÿ".
i hope you can help me with issue.
Thanks in advance.
View 5 Replies
View Related
Nov 8, 2007
What is the purpose of the error output for an OLE DB Source component. Any sql that would cause an error such as converting a character to a number or division by zero causes the OLE DB Source component to fail regardless of the settings for the error output. Works perfect for OLE DB Destination but I cannot come up with any scenario where it would work for the OLE DB Source component.
Thanks in advance,
Brad
View 10 Replies
View Related
Aug 3, 2007
In the Input and Output Properties tab under Advance Editor for OLE DB Source, I cannot remove columns. I copied this Source from a standard template and have made the normal changes to make it work. However I keep getting this error...Error: 0xC020837B at Load Server Security, OLE DB Source [1]: The output column "DBName" (1632) on the error output has no corresponding output column on the non-error output.Error: 0xC004706B at Load Server Security, DTS.Pipeline: "component "OLE DB Source" (1)" failed validation and returned validation status "VS_ISBROKEN".DBName of course is one of the columns that no longer exist, but I can't remove. Whenever I try to remove one of the columns, I get this error...Error at Load Server Security [OLE DB Source[1]]: The column cannot be deleted. The component does not allow columns to be deleted from this input or output. Is there anything that I can do to remove the columns? Is there just a simple setting that I can change to make this work?
View 6 Replies
View Related
Aug 28, 2015
we need download files from FTP location , so we are using script component as source and when we are using the fallowing code// read a file and write out as columns in rows
WebClient myWebClient = new WebClient();
myWebClient.Credentials = new NetworkCredential(Variables.ftpLogin, Variables.ftpPassword);
// Concatenate the domain with the Web resource filename.
string myStringWebResource = Variables.fileURL + Variables.fileName;
string s = myWebClient.DownloadString(myStringWebResource);
StringReader reader = new StringReader(s);
we are getting the fallowing error The server returned an error: (404) Not Found. are we missing anything in the code.
View 2 Replies
View Related
Aug 17, 2005
What I want to accomplish is that at design time the designer can enter a value for some custom property on my custom task and that this value is accessed at executing time.
View 10 Replies
View Related
Nov 6, 2007
This might be an ignorant question, but I can't figure this out.
What is the purpose of the Error output data flow from the OLEDB Source? I am trying to understand an example of what kind of "error" would cause a row to go down this path, and I can't come up with one.
Does anyone have a good example of how this could be useful?
View 5 Replies
View Related
Aug 17, 2007
I've read about the XML Source sometimes setting error output columns to DT_WSTR(255), but mine is now setting them to DT_NTEXT.
Anyone have any suggestions short of an XML editor? I'm concerned that I might do something to "refresh" the columns and cause the problem again.
View 2 Replies
View Related
Mar 26, 2008
This seems like a simple task that just doesn't work. I have an XML source, and on that source, I have the Error Output configured such that the Trunctations are set to "Ignore failure", and the Errors are all set to "Redirect Row". They are then being redirected to a Row Count transformation.
To set up a test for this, I have an integer type (DT_I4 specifically) that I am populating with an alpha-numeric value. For example:
<BatchID>118a</BatchID>
However, this column prevents my XML source from loading at all, and throws the following error:
The component "XML_SRC - File" (46) failed attempting to write data to output column "BatchID" (2030) on output "Payment Error Output" (115). Input string was not in a correct format.
I checked BatchID (2030) throught the advanced properties of the XML Source, and this is defined as a Unicode text stream [DT_NTEXT] field, so I don't see why there would be a problem.
Is this a bug, or am I overlooking something?
Thanks in advance for your help.
Jerad
View 6 Replies
View Related
Jun 5, 2007
Hi all, while executing my ssis package Im getting this error
" the product level is insufficient for component "data reader source" "
but through the bussiness intelligence while debugging it was executing successfully,
but only after deploying the package on to the IS server, while executing getting this error
I checked with the server version also, its was with service pack 2
can I get any help
thanks in advance
View 1 Replies
View Related
Oct 3, 2007
I have a data source that I access via odbc in a DataReader Source component in SSIS. I can access the data fine. However, I am having problems with certain fields that are numeric (specifically home prices ranging from 100,000.00 to 99,999,999.00). In the advanced editor for my data reader source under the input and output properties tab, in data reader output under the external columns and output columns, these fields for some reason default to numeric data types with a precision of 4 and a scale of zero, not large enough to hold the data that is coming in. This causes errors that make the data come in as null (after i specify to ignore the errors).
I can change the precision and scale to 18 and 4 in the external columns, but when I try to change the datatype, precision or scale in the output columns I get the following message:
Property Value is not valid.
The details are:
Error at Import DataReader Source: The data type of output columns on the component "DataReader Source" cannot be changed.
Error at DataReader Source: System.Runtime.InteropServices.COMException (0xC020837D)
at Microsoft.SqlServer.Dts.Pipeline.DataReaderSourceAdapter.SetOutputColumnDataTypeProperties(Int32 iOutputID, Int32 iOutputColumnID, DataType eDataType, Int32 iLength, Int32 iPrecision, Int32 iScale, Int32 iCodePage)
at Microsoft.SqlServer.Dts.Pipeline.ManagedComponentHost.HostSetOutputColumnDataTypeProperties(IDTSManagedComponentWrapper90 wrapper, Int32 iOutputID, Int32 iOutputColumnID, DataType eDataType, Int32 iLength, Int32 iPrecision, Int32 iScale, Int32 iCodePage)
Any help is greatly appreciated.
Dave
View 1 Replies
View Related