Error: System.Runtime.InteropServices.COMException ...

Oct 10, 2006

Error: System.Runtime.InteropServices.COMException (0x80040428): Exception from HRESULT: 0x80040428 at DTS.PackageClass.Execute() at Microsoft.SqlServer.Dts.Tasks.Exec80PackageTask.Exec80PackageTask.ExecuteThread()



Can anyone tell what caused this error when I tried to run the DTS package from my SSIS package ?



Thanks.

Steve

View 4 Replies


ADVERTISEMENT

ReportServicesConfigUI.WMIProvider.WMIProviderException: System.Runtime.InteropServices.COMException (0x8000000A)

Aug 3, 2007

Hi there!
I installed the Sql Reporting Services under Vista Business.
When i run de configuration tool, i have to select yhe machine name and instance name... then when i press connect this exception is thrown


ReportServicesConfigUI.WMIProvider.WMIProviderException: A WMI error has occurred and no additional error information is available. ---> System.Runtime.InteropServices.COMException (0x8000000A)
at System.Runtime.InteropServices.Marshal.ThrowExceptionForHRInternal(Int32 errorCode, IntPtr errorInfo)
at System.Management.ManagementObject.InvokeMethod(String methodName, ManagementBaseObject inParameters, InvokeMethodOptions options)
at ReportServicesConfigUI.WMIProvider.RSInstance.RefreshServerStatus()
--- End of inner exception stack trace ---
at ReportServicesConfigUI.WMIProvider.RSInstance.RefreshServerStatus()
at ReportServicesConfigUI.WMIProvider.RSInstance.get_DelayLoadConfiguration()
at ReportServicesConfigUI.WMIProvider.RSInstance.get_Item(ConfigurationItemNames itemName)
at ReportServicesConfigUI.ConfigurationManager.ResetStepStatus()
at ReportServicesConfigUI.ConfigurationManager.ChangeMachine()
at ReportServicesConfigUI.ConfigurationManager.LaunchDialog()
at ReportServicesConfigUI.ConfigurationManager.tsbConnect_Click(Object sender, EventArgs e)
at System.Windows.Forms.ToolStripItem.RaiseEvent(Object key, EventArgs e)
at System.Windows.Forms.ToolStripButton.OnClick(EventArgs e)
at System.Windows.Forms.ToolStripItem.HandleClick(EventArgs e)
at System.Windows.Forms.ToolStripItem.HandleMouseUp(MouseEventArgs e)
at System.Windows.Forms.ToolStripItem.FireEventInteractive(EventArgs e, ToolStripItemEventType met)
at System.Windows.Forms.ToolStripItem.FireEvent(EventArgs e, ToolStripItemEventType met)
at System.Windows.Forms.ToolStrip.OnMouseUp(MouseEventArgs mea)
at System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks)
at System.Windows.Forms.Control.WndProc(Message& m)
at System.Windows.Forms.ScrollableControl.WndProc(Message& m)
at System.Windows.Forms.ToolStrip.WndProc(Message& m)
at System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m)
at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m)
at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)

Can anyone help me with this. it's Urgent
Thanks
Rui Fernandes

View 5 Replies View Related

Runtime Connect Error To ODBC System DSN

Feb 24, 2006

Hello,

I have created an SSIS package to retrieve data from a Lotus Notes database using the NotesSQL 3.02g ODBC driver.

In SSIS design mode, I can connect to the Notes datasource using the following connection string without any validation errors.

uid=UserID;Dsn=LN_Costs;

I have tried other variations of the connection string including every possible connection string parameter available to the driver as follows.

server=Server_Name;uid=UserID;Dsn=DSN_Name;Driver={Lotus NotesSQL Driver (*.nsf)};database=costing/productcost.nsf;username=UserID;encryptpwd=encrypted_password;maxsubquery=20;maxstmtlen=4096;maxrels=20;maxvarcharlen=254;keeptempidx=1;maxlongvarcharlen=512;showimplicitflds=0;mapspecialchars=1;threadtimeout=60;

Using the above connection strings in SSIS design mode, the datasource test succeeds, and an sql select statement in a datasource reader returns the table structure with no error.

However, when I try to run the package, I receive the following error.

SSIS package "Sales Data Load.dtsx" starting.
Information: 0x4004300A at Data Flow Task, DTS.Pipeline: Validation phase is beginning.
Error: 0xC0047062 at Data Flow Task, DataReader Source 2 [408]: System.Data.Odbc.OdbcException: ERROR [IM002] [Microsoft][ODBC Driver Manager] Data source name not found and no default driver specified
at Microsoft.SqlServer.Dts.Runtime.Wrapper.IDTSConnectionManager90.AcquireConnection(Object pTransaction)
at Microsoft.SqlServer.Dts.Pipeline.DataReaderSourceAdapter.AcquireConnections(Object transaction)
at Microsoft.SqlServer.Dts.Pipeline.ManagedComponentHost.HostAcquireConnections(IDTSManagedComponentWrapper90 wrapper, Object transaction)
Error: 0xC0047017 at Data Flow Task, DTS.Pipeline: component "DataReader Source 2" (408) failed validation and returned error code 0x80131937.
Error: 0xC004700C at Data Flow Task, DTS.Pipeline: One or more component failed validation.
Error: 0xC0024107 at Data Flow Task: There were errors during task validation.
SSIS package "Sales Data Load.dtsx" finished: Failure.

Furthermore, I have packages configured in SQL 2000 DTS to use the same system dsn without any errors.

Why doesn't this work in SQL 2005 SSIS?

Thanks.

View 4 Replies View Related

Runtime Connect Error To ODBC System DSN

Feb 24, 2006

Hello,

I have created an SSIS package to retrieve data from a Lotus Notes database using the NotesSQL 3.02g ODBC driver.

In SSIS design mode, I can connect to the Notes datasource using the following connection string without any validation errors.

uid=UserID;Dsn=LN_Costs;

I have tried other variations of the connection string including every possible connection string parameter available to the driver as follows.

server=Server_Name;uid=UserID;Dsn=DSN_Name;Driver={Lotus NotesSQL Driver (*.nsf)};database=costing/productcost.nsf;username=UserID;encryptpwd=encrypted_password;maxsubquery=20;maxstmtlen=4096;maxrels=20;maxvarcharlen=254;keeptempidx=1;maxlongvarcharlen=512;showimplicitflds=0;mapspecialchars=1;threadtimeout=60;

Using the above connection strings in SSIS design mode, the datasource test succeeds, and an sql select statement in a datasource reader returns the table structure with no error.

However, when I try to run the package, I receive the following error.

SSIS package "Sales Data Load.dtsx" starting.
Information: 0x4004300A at Data Flow Task, DTS.Pipeline: Validation phase is beginning.
Error: 0xC0047062 at Data Flow Task, DataReader Source 2 [408]: System.Data.Odbc.OdbcException: ERROR [IM002] [Microsoft][ODBC Driver Manager] Data source name not found and no default driver specified
at Microsoft.SqlServer.Dts.Runtime.Wrapper.IDTSConnectionManager90.AcquireConnection(Object pTransaction)
at Microsoft.SqlServer.Dts.Pipeline.DataReaderSourceAdapter.AcquireConnections(Object transaction)
at Microsoft.SqlServer.Dts.Pipeline.ManagedComponentHost.HostAcquireConnections(IDTSManagedComponentWrapper90 wrapper, Object transaction)
Error: 0xC0047017 at Data Flow Task, DTS.Pipeline: component "DataReader Source 2" (408) failed validation and returned error code 0x80131937.
Error: 0xC004700C at Data Flow Task, DTS.Pipeline: One or more component failed validation.
Error: 0xC0024107 at Data Flow Task: There were errors during task validation.
SSIS package "Sales Data Load.dtsx" finished: Failure.

Furthermore, I have packages configured in SQL 2000 DTS to use the same system dsn without any errors.

Why doesn't this work in SQL 2005 SSIS?

Thanks.

View 12 Replies View Related

.NET Runtime 2.0 Error Reporting Event Id 5000 System.nullreferenceexception

Aug 29, 2006

I only found http://forums.microsoft.com/TechNet/ShowPost.aspx?PostID=389835&SiteID=17 regarding this error message and it was of no help to me.

Background: 3rd party program that extracts users from a AD group and manage user creation i a MSSQL 2000 server. Also sends e-mails using the SMTP service. The funny thing is that the program manages everything correctly, but writes an error in the Event log as it exists (below). Job is scheduled with the SQL server agent and runs with a doamin user that has local admin rights. We have the same setup on a testserver where it runs without problems.

Windows server 2003, MDAC 2.8, SQL Server 2000 SP3, .NET framework 2 on both servers.

Event Type: Error
Event Source: .NET Runtime 2.0 Error Reporting
Event Category: None
Event ID: 5000
Date: 2006-08-29
Time: 09:16:28
User: N/A
Computer: STHPS0125
Description:
EventType clr20r3, P1 bzadbatch.exe, P2 1.0.0.0, P3 44e5c349, P4 bzadbatch, P5 1.0.0.0, P6 44e5c349, P7 25, P8 308, P9 system.nullreferenceexception, P10 NIL.

For more information, see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.
Data:
0000: 63 00 6c 00 72 00 32 00 c.l.r.2.
0008: 30 00 72 00 33 00 2c 00 0.r.3.,.
0010: 20 00 62 00 7a 00 61 00 .b.z.a.
0018: 64 00 62 00 61 00 74 00 d.b.a.t.
0020: 63 00 68 00 2e 00 65 00 c.h...e.
0028: 78 00 65 00 2c 00 20 00 x.e.,. .
0030: 31 00 2e 00 30 00 2e 00 1...0...
0038: 30 00 2e 00 30 00 2c 00 0...0.,.
0040: 20 00 34 00 34 00 65 00 .4.4.e.
0048: 35 00 63 00 33 00 34 00 5.c.3.4.
0050: 39 00 2c 00 20 00 62 00 9.,. .b.
0058: 7a 00 61 00 64 00 62 00 z.a.d.b.
0060: 61 00 74 00 63 00 68 00 a.t.c.h.
0068: 2c 00 20 00 31 00 2e 00 ,. .1...
0070: 30 00 2e 00 30 00 2e 00 0...0...
0078: 30 00 2c 00 20 00 34 00 0.,. .4.
0080: 34 00 65 00 35 00 63 00 4.e.5.c.
0088: 33 00 34 00 39 00 2c 00 3.4.9.,.
0090: 20 00 32 00 35 00 2c 00 .2.5.,.
0098: 20 00 33 00 30 00 38 00 .3.0.8.
00a0: 2c 00 20 00 73 00 79 00 ,. .s.y.
00a8: 73 00 74 00 65 00 6d 00 s.t.e.m.
00b0: 2e 00 6e 00 75 00 6c 00 ..n.u.l.
00b8: 6c 00 72 00 65 00 66 00 l.r.e.f.
00c0: 65 00 72 00 65 00 6e 00 e.r.e.n.
00c8: 63 00 65 00 65 00 78 00 c.e.e.x.
00d0: 63 00 65 00 70 00 74 00 c.e.p.t.
00d8: 69 00 6f 00 6e 00 20 00 i.o.n. .
00e0: 4e 00 49 00 4c 00 0d 00 N.I.L...
00e8: 0a 00 ..

I'm not a developer, so I'm pretty lost why it behaves like this on one server and not the other. Checked Aspnet.config-file and they are the same. Found this

http://support.microsoft.com/?id=911816

that described that the exception handling was different between the .NET-versions, but since this works on one of the servers, it shouldn't be related, or could it? Tried changing the setting in method 2, but with the same behaviour. Any ideas?

Best regards

/ Jan

View 1 Replies View Related

System.Data.SqlClient.SqlError: Cannot Open Backup Device '\.Tape0'. Operating System Error 5(error Not Found). (Microsoft.Sql

Nov 25, 2007

System.Data.SqlClient.SqlError: Cannot open backup device '\.Tape0'. Operating system error 5(error not found). (Microsoft.SqlServer.express.Smo)

i have only one sql instance and tape is istalled successfully.
please help me to find solution for this error.

Thanks,

View 2 Replies View Related

AcquireConnection Throws COMException (0x80131904) In Custom Component

Mar 25, 2007

We have built a custom component that is run in a dataflow contained in a sequence container, which in turn is contained in a loop. Transactions are enabled on the sequence container in such a way that if one step in the loop fails, that step is rolled back but the loop continues. Now, whenever anything happens causing a rollback in one of the iterations, sometimes the call to AcquireConnection in the next iteration will fail with the following error:

Error: 2007-03-25 09:47:31.98
Code: 0xC0047062
Source: KODPLAN Surrogate Key KO_ID [8204]
Description: System.Runtime.InteropServices.COMException (0x80131904): Exception from HRESULT: 0x80131904
at Microsoft.SqlServer.Dts.Runtime.Wrapper.IDTSConnectionManager90.AcquireConnection(Object pTransaction)
at Intellibis.SqlServer.Dts.SurrogateKeyTransform.AcquireConnections(Object transaction)
at Microsoft.SqlServer.Dts.Pipeline.ManagedComponentHost.HostAcquireConnections(IDTSManagedComponentWrapper90wrapper, Object transaction)
End Error

Is there a way to avoid this? It causes that particular iteration to fail as well as the one causing the rollback.

Regards,
Lars

View 5 Replies View Related

Why Am I Getting An Error Runtime Error Conversion String Type Pr_h_reqby To Int

Jan 17, 2007

here is my code the falue of pr_h_reqby is "Test" 
Dim strconn As New SqlConnection(connstring)
Dim myReqdata As New DataSet
Dim mycommand As SqlDataAdapter
Dim sqlstr As String = "select pr_H_reqby from tbl_pr_header where pr_h_recid = " & recid & ""
mycommand = New SqlDataAdapter(sqlstr, strconn)
mycommand.Fill(myReqdata, "mydata")
If myReqdata.Tables(0).Rows.Count > 0 Then
'lblReqID.Text = myReqdata.Tables(0).Rows("reqid").ToString
lblNameVal.Text = myReqdata.Tables("mydata").Rows("pr_H_reqby").ToString()
lblEmailVal.Text = myReqdata.Tables("mydata").Rows("pr_h_reqemail").ToString()
lblReqDateVal.Text = myReqdata.Tables("mydata").Rows("pr_h_reqdate").ToString()
lblneedval.Text = myReqdata.Tables("mydata").Rows("pr_h_needdt").ToString()
lblDeptval.Text = myReqdata.Tables("mydata").Rows("pr_h_dept").ToString()
txtbxReqDesc.Text = myReqdata.Tables("mydata").Rows("pr_h_projdesc").ToString()
End If

View 1 Replies View Related

Operating System Error 1450(Insufficient System Resources Exist To Complete The Requested Service.).

Jan 29, 2007

Hello!

Hopefully someone can help me.

I have scripts to refresh database as SQL daily jobs. (O.S is Win2K3 and SQL server 2000 and SP4) It was worked and I got the following message this morning from SQL error log.

Internal I/O request 0x5FDA3C50: Op: Read, pBuffer: 0x0D860000, Size: 65536, Position: 25534864896, RetryCount: 10, UMS: Internal: 0x483099C8, InternalHigh: 0x0, Offset: 0xF1FF1E00, OffsetHigh: 0x5, m_buf: 0x0D860000, m_len: 65536, m_actualBytes: 0, m_errcode: 1450, BackupFile: \XAPROD12MASTERXAPRODXAPROD_db_200701290000.BAK

BackupMedium::ReportIoError: read failure on backup device '\XAPROD12MASTERXAPRODXAPROD_db_200701290000.BAK'. Operating system error 1450(Insufficient system resources exist to complete the requested service.).



View 1 Replies View Related

Operating System Error Code 3(The System Cannot Find The Path Specified.).

Jul 20, 2005

Hi All,I use Bulk insert to put data to myTable.When the SQL server is in local machin, it works well. But when I putthe data in a sql server situated not locally, then I get a errormessage like this:Could not bulk insert because file 'C:Data2003txtfilesabif_20031130.txt' could not be opened. Operating systemerror code 3(The system cannot find the path specified.).BULK INSERT myTableFROM 'C:Data2003 txtfilesabif_20031130.txt'with (-- codepage = ' + char(39) + 'ACP' + char(39) + ',fieldterminator = ';',rowterminator = '',keepnulls,maxerrors=0)Someone can explan me what the error shows upThanks in advance- Loi -

View 3 Replies View Related

System.InvalidOperationException: There Is An Error In XML Document (11, 2). System.ArgumentException: Item Has Already Bee

Jul 5, 2007

Hello,



I am getting the following error from my SqlClr proc. I am using a third party API, which is making call to some webservice.



System.InvalidOperationException: There is an error in XML document (11, 2). ---> System.ArgumentException: Item has already been added. Key in dictionary: 'urn:iControl:Common.ULong64' Key being added: 'urn:iControl:Common.ULong64'

System.ArgumentException:

at System.Collections.Hashtable.Insert(Object key, Object nvalue, Boolean add)

at System.Collections.Hashtable.Add(Object key, Object value)

at System.Xml.Serialization.XmlSerializationReader.AddReadCallback(String name, String ns, Type type, XmlSerializationReadCallback read)

at Microsoft.Xml.Serialization.GeneratedAssembly.XmlSerializationReader1.InitCallbacks()

at System.Xml.Serialization.XmlSerializationReader.ReadReferencingElement(String name, String ns, Boolean elementCanBeType, String& fixupReference)

at System.Xml.Serialization.XmlSerializationReader.ReadReferencingElement(String name, String ns, String& fixupReference)

at Microsoft.Xml.Serialization.GeneratedAssembly.XmlSerializationReader1.Read5926_get_failover_stateResponse()

at Microsoft.Xml.Serialization.GeneratedAssembly.ArrayOfObjectSerializer8221.Deserialize(XmlSerializationReader reader)

at System.Xml.Serialization.XmlSerializer.Deserialize(XmlReader xmlReader, String encodingStyle, Xml

...

System.InvalidOperationException:

at System.Xml.Serialization.XmlSerializer.Deserialize(XmlReader xmlReader, String encodingStyle, XmlDeserializationEvents events)

at System.Xml.Serialization.XmlSerializer.Deserialize(XmlReader xmlReader, String encodingStyle)

at System.Web.Services.Protocols.SoapHttpClientProtocol.ReadResponse(SoapClientMessage message, WebResponse response, Stream responseStream, Boolean asyncCall)

at System.Web.Services.Protocols.SoapHttpClientProtocol.Invoke(String methodName, Object[] parameters)

at iControl.SystemFailover.get_failover_state()

at F5CacheManager.GetActiveLBIPaddress()



Found a similar problem in a different thread, but couldn't find any solution. I was wondering if there is an open case for this issue?

https://forums.microsoft.com/MSDN/ShowPost.aspx?PostID=398142&SiteID=1

View 4 Replies View Related

DTS Runtime Error

May 2, 2001

I'm running a package on SQL Server 7, SP2 created in the same environment.
When running a package from DTS Designer, I get an execution status of "Error Occurred" in the Package Execution Status dialog on one of the data pump tasks I'm running along with the number of rows inserted. When I double-click on the task, I get the following message: " The Connection is currently being used by a task. The connection cannot be closed or reused".

Both the exception log for the task and the package, specified for error output, indicate the task ran successfully and the clients confirm that the appropriate number of rows have been inserted in the table. Has anyone encountered this error that can explain the cause/cure?

View 1 Replies View Related

DTS Package Gives Me A Runtime Error

Mar 7, 2007

Hi,
 I am trying to create a DTS package dynamically. I have taken all these steps i.e.,
1. SN.EXE -K c:DTS.KEY2.tlbimp.exe "C:program filesmicrosoft SQL Sever80ToolsBindtspkg.dll" /out:c:Microsoft.SQLServer.DTSPkg80.dll /Keyfile:c:DTS.KEY3.gacutil.exe -i C:Microsoft.SQLServer.DTSPkg80.dll.
Now when i compile the code, i didnt get any compilation error. But when execute the code it gives me a runtime error which goes as given below :
An unhandled exception of type 'System.InvalidCastException' occurred in DTSFactory.exe
Additional information: QueryInterface for interface Microsoft.SQLServer.DTSPkg80.CustomTask failed.
I  am getting this error near the line : oCustTask = (DTS.DataPumpTask2)oTask.CustomTask;
The following is the code.
using System;
using System.Drawing;
using System.Collections;
using System.ComponentModel;
using System.Windows.Forms;
using System.Data;
using DTS = Microsoft.SQLServer.DTSPkg80;
namespace DTSFactory
{
/// <summary>
/// Summary description for Form1.
///This is assuming that all steps have been taken in the following document:
///http://SQLDEV.NET/DTS/DotNetCookBook.htm
///SN.EXE -K c:DTS.KEY
///tlbimp.exe "C:program filesmicrosoft SQL Sever80ToolsBindtspkg.dll" /out:c:Microsoft.SQLServer.DTSPkg80.dll
///Keyfile:c:DTS.KEY
///gacutil.exe -i C:Microsoft.SQLServer.DTSPkg80.dll
///These steps are needed for interop with dtspkg.dll
/// </summary>
public class Form3 : System.Windows.Forms.Form
{
/// <summary>
/// Required designer variable.
/// </summary>
private System.ComponentModel.Container components = null;
private System.Windows.Forms.Button button1;
public DTS.Package2Class pkg = new DTS.Package2Class();
public Form3()
{
//
// Required for Windows Form Designer support
//
InitializeComponent();
//
// TODO: Add any constructor code after InitializeComponent call
//
}
private void Form3_Load(object sender, System.EventArgs e)
{
 
}
/// <summary>
/// Clean up any resources being used.
/// </summary>
protected override void Dispose( bool disposing )
{
if( disposing )
{
if(components != null)
{
components.Dispose();
}
}
base.Dispose( disposing );
}
 
#region Windows Form Designer generated code
/// <summary>
/// Required method for Designer support - do not modify
/// the contents of this method with the code editor.
/// </summary>
private void InitializeComponent()
{
this.button1 = new System.Windows.Forms.Button();
this.SuspendLayout();
//
// button1
//
this.button1.Location = new System.Drawing.Point(0, 0);
this.button1.Name = "button1";
this.button1.Size = new System.Drawing.Size(40, 56);
this.button1.TabIndex = 0;
this.button1.Text = "button1";
this.button1.Click += new System.EventHandler(this.button1_Click);
//
// Form3
//
this.AutoScaleBaseSize = new System.Drawing.Size(5, 13);
this.ClientSize = new System.Drawing.Size(648, 429);
this.Controls.Add(this.button1);
this.Name = "Form3";
this.Text = "Form3";
this.Load += new System.EventHandler(this.Form3_Load);
this.ResumeLayout(false);
}
#endregion
private void button1_Click(object sender, System.EventArgs e)
{
initpackage();
}
public void initpackage()
{
CreateConnections();
CreatePackageSteps();
DefinTasks(pkg);
pkg.Name="MyCSharpDTSTest";
pkg.Description = "CShart DTS Test";
object MIA=System.Reflection.Missing.Value;
pkg.SaveToSQLServer("MyServerName", "MyUserID", "MyPassword",
DTS.DTSSQLServerStorageFlags.DTSSQLStgFlag_Default, "","","",ref
MIA,false);
pkg.Execute();
pkg.UnInitialize();
pkg = null;
}
public void CreateConnections()
{
DTS.Connection txtConn,sqlConn;
 
txtConn = pkg.Connections.New("DTSFlatFile");
//label1.Text = label2.Text = "";
 
//for (int i=1;i<txtConn.ConnectionProperties.Count;i++)
// label1.Text = label1.Text + "
" + txtConn.ConnectionProperties.Item(i).Name;
//for text connection
//start
txtConn.ConnectionProperties.Item(1).Value = "C:\FlatFiles\1.txt";
txtConn.ConnectionProperties.Item(3).Value = 1;
txtConn.ConnectionProperties.Item(4).Value = "
";
txtConn.ConnectionProperties.Item(5).Value = 1;
txtConn.ConnectionProperties.Item(7).Value = "|";
txtConn.ConnectionProperties.Item(9).Value = 1;
txtConn.ConnectionProperties.Item(10).Value = 0;
txtConn.ConnectionProperties.Item(11).Value = """;
txtConn.ConnectionProperties.Item(12).Value = false;
txtConn.ConnectionProperties.Item(14).Value = 0;
txtConn.ConnectionProperties.Item(18).Value = 255;
 
txtConn.Name = "Text File (Source)";
txtConn.ID = 1;
txtConn.Reusable = true;
txtConn.ConnectImmediate = false;
txtConn.DataSource = "C:\FlatFiles\1.txt";
txtConn.ConnectionTimeout = 60;
txtConn.UseTrustedConnection = false;
txtConn.UseDSL = false;
//end
pkg.Connections.Add(txtConn);
sqlConn = pkg.Connections.New("SQLOLEDB");
 
//for (int i=1;i<sqlConn.ConnectionProperties.Count;i++)
// label2.Text = label2.Text + "
" + sqlConn.ConnectionProperties.Item(i).Name;
sqlConn.ConnectionProperties.Item(3).Value = true;
sqlConn.ConnectionProperties.Item(4).Value = "sa";
sqlConn.ConnectionProperties.Item(5).Value = "FCSUAT";
sqlConn.ConnectionProperties.Item(6).Value = "(local)";
sqlConn.ConnectionProperties.Item(19).Value = "DTS Designer";
 
sqlConn.Name = "Microsoft OLE DB Provider for SQL Server";
sqlConn.ID = 2;
sqlConn.Reusable = true;
sqlConn.ConnectImmediate = false;
sqlConn.DataSource = "(local)";
sqlConn.UserID = "sa";
sqlConn.ConnectionTimeout = 60;
sqlConn.Catalog = "FCSUAT";
sqlConn.UseTrustedConnection = false;
sqlConn.UseDSL = false;
 
pkg.Connections.Add(sqlConn);
 
}
public void CreatePackageSteps()
{
DTS.Step2 oStep = (DTS.Step2)pkg.Steps.New();
oStep.Name = "Copying Data from myTableName";
oStep.Description = "Copying Data from myTableName";
oStep.TaskName = "Copying Data from myTableName";
oStep.CommitSuccess = false;
oStep.RollbackFailure = false;
oStep.ScriptLanguage = "VBScript";
oStep.AddGlobalVariables = true;
oStep.CloseConnection = false;
oStep.ExecuteInMainThread = true;
oStep.IsPackageDSORowset = false;
oStep.JoinTransactionIfPresent = false;
oStep.DisableStep = false;
oStep.FailPackageOnError = true;
pkg.Steps.Add(oStep);
oStep = null;
}
public void DefinTasks(DTS.Package2Class package)
{
DTS.DataPumpTask2 oCustTask;
DTS.Task oTask;
oTask = package.Tasks.New("DTSDataPumpTask");
oCustTask = (DTS.DataPumpTask2)oTask.CustomTask;
oCustTask.Name = "Copying Data from myTableName";
oCustTask.Description = "Copying Data from myTableName to MyDestDB.myTableName";
DTS.DataPumpTask2 oDataPump = (DTS.DataPumpTask2)oTask.CustomTask;
oDataPump.SourceConnectionID = 1;
oDataPump.SourceSQLStatement = "SELECT `MyField` FROM myTableName";
oDataPump.DestinationConnectionID =2;
oDataPump.DestinationObjectName = "myTableName";
oDataPump.ProgressRowCount = 1000;
oDataPump.MaximumErrorCount = 0;
oDataPump.FetchBufferSize = 1;
oDataPump.UseFastLoad=true;
oDataPump.InsertCommitSize = 0;
oDataPump.InsertCommitSize = 500000;
oDataPump.ExceptionFileColumnDelimiter = "|";
oDataPump.ExceptionFileRowDelimiter = "
";
oDataPump.AllowIdentityInserts = false;
oDataPump.FirstRow = 0;
oDataPump.LastRow = 0;
CreateTaskTrans(oDataPump, oCustTask);
pkg.Tasks.Add(oTask);
oCustTask = null;
oTask = null;
}
public void CreateTaskTrans(DTS.DataPumpTask DatPump,
DTS.DataPumpTask2 CustTask)
{
DTS.Transformation2 oTransformation;
oTransformation =
(DTS.Transformation2)CustTask.Transformations.New("DTS.DataPumpTransformCopy");
oTransformation.Name = "DirectCopyXform";
oTransformation.TransformFlags = 63;
oTransformation.ForceSourceBlobsBuffered = 0;
oTransformation.ForceBlobsInMemory = false;
oTransformation.InMemoryBlobSize = 1048576;
oTransformation.SourceColumns.AddColumn("MyField",1);
oTransformation.DestinationColumns.AddColumn("MyField",1);
DatPump.Transformations.Add(oTransformation);
}
}
}
 
Can anyone help me in solving this? 
Thanks in advance.

View 1 Replies View Related

Runtime Error -2147467259

Jan 7, 2008

Hello there.

1. Can someone help me?
I am running an eCommerce website using SQL Server 2000, as of last week it was working just fine, today I try to access the sight and I get the following error below.

I haven't changed anything on the server, the SQL Server services is running so is the agent.


Operation: Creating Engine object
Error number: -2147467259
Error source: Microsoft OLE DB Provider for SQL Server DatabaseUtils.OpenCommand DatabaseFile.IsDatabaseByteArrayUpdated SchemaFile.IsDatabaseSchemaUpdated Environment.InitEnvironment, Step: Loading database schema Engine.Init Engine.Refresh
Error description: [DBNETLIB][ConnectionOpen (Connect()).]SQL Server does not exist or access denied.

2. When I refresh the browser I get this error:

Operation: Creating Engine object
Error number: 424
Error source: Microsoft VBScript runtime error
Error description: Object required


Thanks in advance

View 2 Replies View Related

Query Error During Runtime

Jul 23, 2005

I get Invalid object name 'bstr'. when I try to run this querySelect distinct c0.oid, c1.Value, c2.Value, c3.ValueFrom(SELECT oid FROM dbo.COREAttributeWHERE CLSID IN ('{1449DB2B-DB97-11D6-A551-00B0D021E10A}','{1449DB2D-DB97-11D6-A551-00B0D021E10A}','{1449DB2F-DB97-11D6-A551-00B0D021E10A}','{1449DB31-DB97-11D6-A551-00B0D021E10A}','{1449DB33-DB97-11D6-A551-00B0D021E10A}','{1449DB35-DB97-11D6-A551-00B0D021E10A}','{1449DB37-DB97-11D6-A551-00B0D021E10A}','{1449DB39-DB97-11D6-A551-00B0D021E10A}','{1449DB3B-DB97-11D6-A551-00B0D021E10A}','{1449DB3D-DB97-11D6-A551-00B0D021E10A}','{1449DB3F-DB97-11D6-A551-00B0D021E10A}','{1449DB43-DB97-11D6-A551-00B0D021E10A}','{1449DB45-DB97-11D6-A551-00B0D021E10A}','{1449DB47-DB97-11D6-A551-00B0D021E10A}','{1449DB49-DB97-11D6-A551-00B0D021E10A}','{1449DB4B-DB97-11D6-A551-00B0D021E10A}','{1449DB4D-DB97-11D6-A551-00B0D021E10A}','{1449DB51-DB97-11D6-A551-00B0D021E10A}','{DAA598D9-E7B5-4155-ABB7-0C2C24466740}','{6921DAC3-5F91-4188-95B9-0FCE04D3A04D}','{128F17D4-2014-480A-96C6-370599F32F67}','{9F3A64C9-28F3-440B-B694-3E341471ED8E}','{2E3AB438-7652-4656-9A18-4F9C1DC27E8C}','{B69E74A7-0E48-4BA2-B4B7-5D9FFEDC2D97}','{2BB836D3-2DC1-4899-9406-6A495ED395C3}','{9CFFDC3A-5DF5-4AD8-B067-6EF5A9736681}','{E18E470B-B297-43D2-B9CD-71AF65654970}','{9BDCDA97-1171-409D-B3AB-71DA08B1E6D3}','{0E91AC62-7929-4B42-B771-7A6399A9E3B0}','{C8BAE335-CCB7-4F1D-8E9D-85C301188BE2}','{97E6E186-8F32-42E6-B81C-8E2E0D7C5ABA}','{BE5B6233-D4E7-4EF6-B5FC-91EA52128723}','{4ECDAAE1-828A-4C43-8A66-A7AB6966F368}','{19082B90-EF02-45CC-B037-AFD0CF91D69E}','{6F76CEF7-EBC0-48C6-8B78-C5330324C019}','{18492042-B22A-4370-BFA3-D0481800BBC7}','{A71343AD-CC09-4033-A224-D2D8C300904A}','{EC10BD0A-FDE3-4484-BEA6-D5A2E456256C}','{F7F8A4E1-651A-4A48-B55A-E8DA59D401B2}','{A923226F-B920-4CFA-9B0D-F422D1C36902}','{A95ACA6A-16AC-47E4-A9A6-F530D50A475A}','{C31DB61A-5221-42CF-9A73-FE76D5158647}')) AS c0 ,(select oid, dispid, valueFROM dbo.COREBSTRAttributeWHERE iid = '{1449DB20-DB97-11D6-A551-00B0D021E10A}') As bstrLEFT JOIN bstr AS c1ON (c0.oid = c1.oid)AND c1.dispid = 28LEFT JOIN bstr AS c2ON (c0.oid = c2.oid)AND c2.dispid = 112LEFT JOIN bstr AS c3ON (c0.oid = c3.oid)AND c3.dispid = 192thanksSunit

View 1 Replies View Related

Runtime Error After Some Pause

Apr 18, 2006

Hello,

My users often view some report for some minutes and after that want to return to parent report.
If they did it after small time (~less than minute), everything is OK. But if this pause is above 1 minute they receive "Runtime Error" message and can only to go to homepage.

I think that this is some session time or something like that.
Am I right? How can fix it?

Thank you

View 12 Replies View Related

.NET Runtime Error On SQL Server 2005 (RTM)

Jan 7, 2006

 

I upgraded my primary production server this morning to SQL 2005.  Everything went fairly smoothly, but a couple of hours after my installation was complete, I found the following error in my event log:
 
Source: .NET Runtime Optimization Service
EventID: 1101
.NET Runtime Optimization Service (clr_optimization_v2.0.50727_32) - Failed to compile: Microsoft.ReportingServices.QueryDesigners, Version=9.0.242.0, Culture=neutral, PublicKeyToken=89845dcd8080cc91 . Error code = 0x80070002
 
I am a little stumped since we did not install Reporting Services.  We only installed Database Services, Integration Services and Workstation Components.  I'm open to any suggestions on this.  This does not seem to be negatively affecting our server, but I do want to resolve it as soon as possible.
 
Thanks,
Kevin
 

View 7 Replies View Related

Microsoft VBScript Runtime Error

Aug 2, 2006

Hello,

I am currently getting the following error:

Microsoft VBScript runtime error '800a000d'

Type mismatch: 'QueryString'

/admin/equipment/addequipment.asp, line 128

This is when i try to submit a new database item in Dreamweaver. The DB I am using is SQL Server 2005.

My code is as follows:

Dim equipspec__urlid
equipspec__urlid = "1"
If (QueryString("ID") <> "") Then
equipspec__urlid = QueryString("ID")
End If
%>
<%
Dim equipspec
Dim equipspec_numRows

Set equipspec = Server.CreateObject("ADODB.Recordset")
equipspec.ActiveConnection = MM_intranet_STRING
equipspec.Source = "SELECT * FROM EquipSpec WHERE " + Replace(equipspec__urlid, "'", "''") + " = EquipSpec.ID"
equipspec.CursorType = 0
equipspec.CursorLocation = 2
equipspec.LockType = 1
equipspec.Open()

Would be greatful if anybody could help, let me know if you need more info.

Many thanks.

View 1 Replies View Related

.NET Runtime 2.0 Error With EventID 5000

Jan 19, 2007

Hi,

We are performing a SQL 2000 to SQL 2005 upgrade on a Windows 2003 SP1 server.

We encountered error in the SQL 2005 upgrade with the following error :



===================================

Common Language Runtime detected an invalid program.

===================================

Common Language Runtime detected an invalid program. (System.Xml)

------------------------------
Program Location:

at System.Xml.Schema.SchemaInfo..ctor()
at System.Xml.Schema.XmlSchemaSet..ctor(XmlNameTable nameTable)
at System.Xml.XmlReaderSettings.get_Schemas()
at Microsoft.SqlServer.UpgradeAdvisor.ReportViewer.UAReportController.LoadAndValidateDataFile()
at Microsoft.SqlServer.UpgradeAdvisor.ReportViewer.UAReport.ValidateDataFile()
at Microsoft.SqlServer.UpgradeAdvisor.ReportViewer.UAIssueReport.Refresh()
at Microsoft.SqlServer.UpgradeAdvisor.ReportPanel.OpenReport(String reportFile)

From the Event Viewer, under Application, we can see the following error :

EventID : 5000

Source :

EventType clr20r3, P1 bpacmd.exe, P2 2005.90.2047.0, P3 443f5935, P4 bpacmdx, P5 9.0.242.0, P6 443f5932, P7 7, P8 7a, P9 microsoft.bpa.common.bpaserver, P10 NIL.



We do urgently need some help now.



Thanks.

View 1 Replies View Related

Runtime Data Source Error

Nov 29, 2006

Hello

I have a defined data source to an oracle server. I've alredy intalled oracle client, and setup my data source to save the user and password. I'm using .NET provider/OracleClient DataProvider Connection. When I click on "Test Connection" Button, SSIS reports SUCCESS. In Connection Manager TAB I created on connection called "OracleServer" from my oracle data source, described above.

In my package, I defined a DataReaderSource task, I specified "OracleServer" as a connection to it. I can preview data and view oracle's columns name..., so it make me think that everything is fine. But when It execute the task it FAIL and notify logon error and that password can't be blank.

Please help, I need read from the oracle server!!

Thank you.

View 2 Replies View Related

Vista32/runtime Error Spoolsv.exe

Apr 6, 2008

My computer is 2 months old and I am using Windows Vista 32. I keep getting an Interactive Services dialog detection box that says 'A Program Cannot display a message on your desktop'. And when I click to see the message

I get a Microsoft Visusal C++ Runtime Library Error that says 'Program C:\Windowssystem32spoolsv.exe'. It says that this application has requested the runtime to terminate in an unusual way.

This error keeps popping up and I don't know how to deactivate it or why it is happening, or what the Interactive Service is. Isn't a system32 file for Windows XP? I think the spoolsv.exe is for a printer, and it looks like the Interactive Service is for networking.....

Can anyone tell me why 1. I keep getting this error message, 2. how to deactivate it, 3. what the Interactive Service is, and 4. if a System32 is an XP file?

Please, help....



View 7 Replies View Related

Error: SSIS Runtime Object Could Not Be Created.

May 26, 2006

I am using SQL Server 2005 Version  9.00.1399.06 (Intel X86).

Whether I try to start a new Integration Services project in Visual Studio or try to import data into a database I receive the following error: 

SSIS Runtime Object could not be created.  Verify the DTS.dll is available and registered.   The wizard can not continue and will terminate.

Unable to cast COM of type 'Microsoft.SqlServer.DTS.Runtime.Wrapper.PackageNeutralClass' to interface type
'Microsoft .SqlServer.DTS.Runtime.Wrapper.IDTSContainer90'
This operation failed because the QueryInterface call on the COM component for the interface failed due to the following error:  Library not registered.  (Exception from HRESULT:  0X80028010) (TYPE_E_LIBNOTREGISTERED)).

I have no idea why I am getting this error and would appreciate any help.  I'm sure some of you SQL Server Gurus will know right away.

 

 

View 7 Replies View Related

SSIS Runtime Object Could Not Be Created Error:

May 30, 2006

I am using SQL Server 2005 Version 9.00.1399.06 (Intel X86).

Whether I try to start a new Integration Services project in Visual Studio or try to import data into a database I receive the following error:

SSIS Runtime Object could not be created. Verify the DTS.dll is available and registered. The wizard can not continue and will terminate.

Unable to cast COM of type 'Microsoft.SqlServer.DTS.Runtime.Wrapper.PackageNeutralClass' to interface type
'Microsoft .SqlServer.DTS.Runtime.Wrapper.IDTSContainer90'
This operation failed because the QueryInterface call on the COM component for the interface failed due to the following error: Library not registered. (Exception from HRESULT: 0X80028010) (TYPE_E_LIBNOTREGISTERED)).

I have no idea why I am getting this error and would appreciate any help. I'm sure some of you SQL Server Gurus will know right away.

View 13 Replies View Related

.NET Runtime Optimization Error On SQL Server 2005

Jan 7, 2006

I posted this on the .NET Framework inside Sql Server forum as well.  Sorry if the cross-post offends anybody.

I upgraded my primary production server this morning to SQL 2005.  Everything went fairly smoothly, but a couple of hours after my installation was complete, I found the following error in my event log:
 
Source: .NET Runtime Optimization Service
EventID: 1101
.NET Runtime Optimization Service (clr_optimization_v2.0.50727_32) - Failed to compile: Microsoft.ReportingServices.QueryDesigners, Version=9.0.242.0, Culture=neutral, PublicKeyToken=89845dcd8080cc91 . Error code = 0x80070002
 
I am a little stumped since we did not install Reporting Services.  We only installed Database Services, Integration Services and Workstation Components.  I'm open to any suggestions on this.  This does not seem to be negatively affecting our server, but I do want to resolve it as soon as possible.
 
Thanks,
Kevin

 

View 47 Replies View Related

SqlDataSource.Select Error: Unable To Cast Object Of Type 'System.Data.DataView' To Type 'System.String'.

Oct 19, 2006

I am trying to put the data from a field in my database into a row in a table using the SQLDataSource.Select statement. I am using the following code: FileBase.SelectCommand = "SELECT Username FROM Files WHERE Filename = '" & myFileInfo.FullName & "'" myDataRow("Username") = CType(FileBase.Select(New DataSourceSelectArguments()), String)But when I run the code, I get the following error:Server Error in '/YorZap' Application. Unable to cast object of type 'System.Data.DataView' to type 'System.String'. Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code. Exception Details: System.InvalidCastException: Unable to cast object of type 'System.Data.DataView' to type 'System.String'.Source Error: Line 54: FileBase.SelectCommand = "SELECT Username FROM Files WHERE Filename = '" & myFileInfo.FullName & "'"
Line 55: 'myDataRow("Username") = CType(FileBase.Select(New DataSourceSelectArguments).GetEnumerator.Current, String)
Line 56: myDataRow("Username") = CType(FileBase.Select(New DataSourceSelectArguments()), String)
Line 57:
Line 58: filesTable.Rows.Add(myDataRow)Source File: D:YorZapdir_list_sort.aspx    Line: 56 Stack Trace: [InvalidCastException: Unable to cast object of type 'System.Data.DataView' to type 'System.String'.]
ASP.dir_list_sort_aspx.BindFileDataToGrid(String strSortField) in D:YorZapdir_list_sort.aspx:56
ASP.dir_list_sort_aspx.Page_Load(Object sender, EventArgs e) in D:YorZapdir_list_sort.aspx:7
System.Web.Util.CalliHelper.EventArgFunctionCaller(IntPtr fp, Object o, Object t, EventArgs e) +13
System.Web.Util.CalliEventHandlerDelegateProxy.Callback(Object sender, EventArgs e) +45
System.Web.UI.Control.OnLoad(EventArgs e) +80
System.Web.UI.Control.LoadRecursive() +49
System.Web.UI.Page.ProcessRequestMain(Boolean includeStagesBeforeAsyncPoint, Boolean includeStagesAfterAsyncPoint) +3743
Version Information: Microsoft .NET Framework Version:2.0.50727.42; ASP.NET Version:2.0.50727.210 Please help me!

View 3 Replies View Related

[File System Task] Error: An Error Occurred With The Following Error Message: Access To The Path Is Denied

Sep 7, 2007

Hi -

I have an File System Task that copies a file from one directory ot another. When I hard code the target directory (c:dirfile.txt) it works fine. When I change it to a virtual directory (\serverdirfile.txt) I get a security error:

[File System Task] Error: An error occurred with the following error message: "Access to the path '\gracehbtest oS2TMM_Live_Title_000002.xml' is denied.".

Where do I change the security settings?

Thanks - Grace

View 5 Replies View Related

Unknown Datetime Error In Query (Overflow At Runtime)

Aug 2, 2005

Hi all,

I have the following query...

SELECT    Count(*)
FROM        Incidents I
WHERE (Priority = 1)
AND (Time_First_Unit_On_Scene IS NOT NULL)
AND (DateDiff(s, Time_ClockStart, Time_First_Unit_On_Scene) <= 480) 
AND (Response_Date BETWEEN '1-Apr-2004')
AND ('31-Mar-2005 23:59:59')
AND (I.Disposition_ID <> 9 )

...and I get the following error message...

 System.Data.OleDb.OleDbException: Difference of two datetime columns caused overflow at runtime.

... any one know what it could be?

Thanks

Tryst

View 1 Replies View Related

Runtime Error When Connecting From The Site To Sql Server 2005

Nov 14, 2007


I moved all my databases to sql server 2005 & when appliction is trying to connect to 2005 databases i get the following error
In the connection string i am using
Password=test;Persist Security Info=True;User ID=test;Initial Catalog=test;Data Source=externalip/instancename

this is the only change on the web server


Runtime Error Description: An application error occurred on the server. The current custom error settings for this application prevent the details of the application error from being viewed remotely (for security reasons). It could, however, be viewed by browsers running on the local server machine.

Details: To enable the details of this specific error message to be viewable on remote machines, please create a <customErrors> tag within a "web.config" configuration file located in the root directory of the current web application. This <customErrors> tag should then have its "mode" attribute set to "Off".





<!-- Web.Config Configuration File -->

<configuration>
<system.web>
<customErrors mode="Off"/>
</system.web>
</configuration>
Notes: The current error page you are seeing can be replaced by a custom error page by modifying the "defaultRedirect" attribute of the application's <customErrors> configuration tag to point to a custom error page URL.





<!-- Web.Config Configuration File -->

<configuration>
<system.web>
<customErrors mode="RemoteOnly" defaultRedirect="mycustompage.htm"/>
</system.web>
</configuration>



please let me know the problem

View 7 Replies View Related

Error 80040154 Using Microsoft.SqlServer.Dts.Runtime.Package

May 8, 2008

I am executing an SSIS package from VB.NET code. Works great in design mode. When I publish it (using Click-Once), it works great on development computer but fails on a customer computer:

Microsoft.SqlServer.Dts.Runtime.DtsPipelineException: Retrieving the COM class factory for component with CLSID {E80FE1DB-D1AA-4D6B-BA7E-040D424A925C} failed due to the following error: 80040154. ---> System.Runtime.InteropServices.COMException (0x80040154): Retrieving the COM class factory for component with CLSID {E80FE1DB-D1AA-4D6B-BA7E-040D424A925C} failed due to the following error: 80040154.
at Microsoft.SqlServer.Dts.Runtime.Package..ctor()
--- End of inner exception stack trace ---
at Microsoft.SqlServer.Dts.Runtime.Package..ctor()

My project references Microsoft.SQLServer.ManagedDTS.

The error occurs on the following line:

Dim objPackage As New Microsoft.SqlServer.Dts.Runtime.Package

Looking at various forum threads, it would appear that it's because either (1) DLL(s) are not registered on the customer machine, or (2) DLL(s) are missing from the customer machine. The first explanation doesn't seem right -- even though Microsoft.SQLServer.ManagedDTS is a COM dll, doesn't .NET provide a wrapper when it references it? I downloaded Process Explorer from Sysinternals.com to compare loaded DLLs on my dev box to those on the customer's box and while several dlls are loaded when the line is successfully loaded, all of them exist on the customer box.

Any help would be greatly appreciated.

View 17 Replies View Related

Intermittent Runtime Error When Executing SSIS Package

Sep 12, 2007

Hi,

I'm in the process of writing a fairly complex SSIS package that reads csv files and goes on to load the content into a SQL Server 2005 database.

I am testing the package by executing it from within a Nant script. My test process resets the data in the target database and then loads data from a known set of test data files. Because it's scripted I can be sure that SSIS is being asked to do the same thing, every time in a consistent way.

When I execute the package I frequently (although not always) get an error message dialog mid-ececution that reads:





Code Snippet

Microsoft Visual c++ Runtime Library

Runtime error!

Program: C...

The application has requested the Runtime to terminate it in an unusual way. Please contact the application's support team for more information.

When I click OK the VS Just-In-Time debugger tells me about an unhandled win32 exception in DTExec.exe [4696] and asks me if I wish to debug (which I do not).

No error is reported by SSIS itself, it literally just stops in its tracks.

I will appreciate any help that can be offered here

Nick

View 5 Replies View Related

DTS RunTime Error &#34;received Invalid Column Length From BCP Client&#34;

Jul 26, 2002

when i tried to run a DTS which transfer bulk data between 2 SQL servers, i got following error message:
================================================== ============
Error: -2147467259 (80004005); Provider Error: 4815 (12CF)
Error string: Received invalid column length from bcp client.
Error source: Microsoft OLE DB Provider for SQL Server
Help file:
Help context: 0
================================================== ===========

if anybody has encounter the same problem before? after testing, i think it's
must related with network traffic problem. but i can not figure out how to solve it.

View 2 Replies View Related

Error : Difference Of Two Datetime Columns Caused Overflow At Runtime.

Sep 23, 2005

At my job is a dts package that is failing in SQL 2005. I am not a SQLexpert. I am just trying to fix. I put the query in Query Analyzerand get this error:(4322 row(s) affected)Server: Msg 535, Level 16, State 1, Line 1Difference of two datetime columns caused overflow at runtime.I am just trying to understand what this means, what I should belooking for and what could be wrong. Here is the query:SELECT i.SerialNumber, '' AS mac_number, DATEDIFF([second], 'Jan 1,1970', s.DateOrdered) AS Support_StartDt, DATEDIFF([second], 'Jan 1,1970',s.Warranty_Enddate) AS Support_EndDt,DATEDIFF([second], 'Jan 1, 1970', c.Registration_Date) ASRegistration_Date, c.FirstName AS enduser_fname,c.LastName AS enduser_lname, c.CompanyName ASenduser_companyname, c.ContactEmail AS enduser_email, c.Address ASenduser_address1,c.Address2 AS enduser_address2, c.City ASenduser_city, c.State AS enduser_state, c.Zip AS enduser_zip,c.WorkPhone AS enduser_phone,c.Fax AS enduser_fax, d.DealerName ASdealer_companyname, d.ContactFirstName AS dealer_fname,d.ContactLastName AS dealer_name,d.Address1 AS dealer_address, d.City ASdealer_city, d.State AS dealer_state, d.Zip AS dealer_zip,d.ContactPhone AS dealer_phone,d.ContactFax AS dealer_fax,ISNULL(SUBSTRING(p.ProductName, 11, LEN(p.ProductName) - 10), 'unknownIWP product') AS product_type, '' AS extra1,'' AS extra2, '' AS extra3, '' AS extra4, '' ASextra5, '' AS extra6, '' AS extra7FROM tblInventory i full outer JOINtblDealers d ON i.DealerID = d.DealerID fullOUTER JOINtblSupport s ON i.InventoryID = s.InventoryIDfull outer JOINtblCustomers c ON s.InventoryID = c.InventoryIDLEFT OUTER JOINtblProducts p ON LEFT(i.SerialNumber,PATINDEX('%-%', i.SerialNumber)) = p.SerialPrefixWHERE i.SerialNumber <> ''Any ideas would be greatly appreciated.

View 2 Replies View Related

VB.Net 2005 Setup Creation Gets Error Using Microsoft.SqlServer.Dts.Runtime

Feb 3, 2007

I have a very small project written in VB.Net 2005 using the SQL Server 2005 SSiS DTSx package.

I migrated a SLQ 2000 DTS package using the SQL 2005 Legacy tools and saved the package as a local .DTSx package on our file server.

I need to run the package from a clients PC.

I added the reference Microsoft.SqlServer.ManagedDTS so I could then use the Microsoft.SqlServer.Dts.Runtime so I can execute the commands:

Dim oApp As New Application
Dim oPkg As New Package
oPkg = oApp.LoadPackage(g_DTSx_Directory & "AOC copy Generic1 CSV to AOC_verify_file_1.dtsx", Nothing)
Dim oResults As DTSExecResult
oResults = oPkg.Execute

Ok. That works fine and is basically the entire app. It executes without a hitch in debug and as a compiled exe on my PC, but I have all the tools. So now I try and create a setup project for this and I use the setup wizard.

During the creation of the setup project I get a message that states:
The following files may have dependencies that cannot be determined automatically. Please confirm that all dependencies have been added to the project.
C:windowssystem32msxml6.dll

OK. The dll is part of the reference I mentioned above and I have no idea what other dependencies it may have.

How do I find this out?

Has anyone else created a project like this and experenced the same?

I am on a clean build running WinXP Pro with SP2 - VS2005 with SP1 and the SQL Server 2005 tools.

View 4 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved