I have a package that uses a for loop to iterate through an unknown amount of excel files and pull their data into a table. However, there will be cases when the file is corrupted or has some sort of problem so that either the transformation will fail or the excel data source will fail with an oledb connection error. Could anyone suggest a clean way to trap these errors? Specifically, the "Cannot Aquire Connection from Connection Manager", which is the excel connection.
I have an SSIS package that I need to modify. It was developed in Visual Studio 2005 and runs faithfully in production on SQL Server 2005. Suddenly, I can't open the package on my own workstation. I see a big red "X" image and a message stating "Microsoft Visual Studio is unable to load this document." The real reason the document can't be loaded appears to be:
Error loading DataWarehouseLoader.dtsx: The connection type "OLEDB" specified for connection manager "Warehouse Logging OLE DB" is not recognized as a valid connection manager type. This error is returned when an attempt is made to create a connection manager for an unknown connection type. Check the spelling in the connection type name.
Does anyone know what causes this and what I can do? The package has been in production for 9 months and I've never seen this problem before.
Dts.Connections.Item("myADO.NET connection").AcquireConnection(Nothing)Dim conn As New SqlClient.SqlConnection(Dts.Connections.Item("myADO.NET connection").ConnectionString) conn.Open()
This seems silly, in that I'm not really using the same connection, but using the connection string of a connection that already exists. And, for my purposes, it's not working currently, because I've switched from Windows Authentication to SQL Auth... and the password isn't coming over in the ConnectionString property.How do I re-use the exact same ADO.NET connection I have in my connection manager in a script task? That's the recommended way to go, right?
[One day I will come back here and answer questions, rather than only ask.]
I have a custom connection manager that returns an OleDbConnection. The only thing "custom" about the connection manager is how it determines its connection string. The object returned in AcquireConnection is an OleDbConnection.
OleDbConnection oleDbConnection = new OleDbConnection(this.connectionString); oleDbConnection.Open();
return oleDbConnection; }
Some of the objects within SSIS only work with an OleDbConnection, but mine is not recognized as such. Is there any way to have my connection recognized as a valid connection?
I am getting the following error when trying to EDIT a OLEDB Connection Manager. I am using VS2010. Im not coming up with any answers to this problem. I just reinstalled SQL SERVER CLIENT TOOLS 2012 That includes the SQL DATA TOOLS/VS 2010 But I still receive this error.
Error:Unable to find the requested .Net Framework Data Provider. It may not be installed. (System.Data)
I have OLE DB Connections set up in my connection manager (Native OLE DBMicrosoft OLE DB Provider for SQL Server). I would like to reference and query these connections from a custom task, written in C#. I currently reference it as follows:
What may be obvious to some (though wasn't to me, as I am new at this), when I run the task, I get an error saying that I cannot make this cast. After perusing the boards, I understand that this is because I am not making a cast to the right connection type. Well, that is where I am lost. What connection type (and corresponding library) do I need to reference? I want to continue to use the "Native OLE DB..." connection.
I am trying to dynamically change my initial catalog in a SSIS project. Each day I get a snapshot of data from the production server. I am performing ETL on that database and loading it into my warehouse. I am trying to put something together so that each day I get the latest snapshot and if its newer then my most recent one I pass that new catalog into the connection manager. I can already run the sql script to compare the two catalogs but I can't populate the connection manager.
Any idea about how to configure/read multiple worksheets from a spreadsheet using single connection manager? I think using SQL Command we could able to do - not sure how to achieve that. Let me know the other alternatives too.
I have an SSIS package which takes input from Flat file and transfer the data to SQL Server using OLEDB Destination Data Flow Item. The OLEDB Connection Manager used for the destination is configured to use SQL Server Authentication for the user €˜sa€™. The package works fine without enabling the configurations. But when I enable package configuration and save the configuration of the various connection managers in an XML configuration file and then run the package it gives the following error in the validation phase: [OLE DB Destination [21]] Error: The AcquireConnection method call to the connection manager "<Connection Manager Name>" failed with error code 0xC0202009. And after the validation phase is complete the following error message is given for the package execution: [Connection manager "<Connection Manager Name>"] Error: An OLE DB error has occurred. Error code: 0x80040E4D. An OLE DB record is available. Source: "Microsoft SQL Native Client€? Hresult: 0x80040E4D Description: "Login failed for user 'sa'." Has anyone else run into this? I am running SQL 2005 9.0.1399 and VS 2005 8.0.50727.42 (RTM.50727.4200) on Windows Server 2003 Enterprise Edition SP1. Any suggestions would be welcome. TIA, Robinson
I am using SSIS 2005 on Windows 2003 server. Using Excel Source to dump the data for staging database. I am getting following error while I execute it through BI studio's execute button.
I have deployed my packages into Sql Server and I am using Configuration File. As my Data Source is Excel, I have changed the connection string during deployment with Server Path. But I am getting the following errors. Actually the File Exist in Path. May I know What is cause of the issue? Do I need to give any permission to execute the package.
SSIS Error Code DTS_E_CANNOTACQUIRECONNECTIONFROMCONNECTIONMANAGER. The AcquireConnection method call to the connection manager "Excel Connection Manager" failed with error code 0xC0202009. There may be error messages posted before this with more information on why the AcquireConnection method call failed.
component "Excel Source Service Contract Upload" (1) failed validation and returned error code 0xC020801C.
One or more component failed validation.
There were errors during task validation.
DTS_E_OLEDBERROR, Error Code: 0x80004005 Source: "MS JET DB Engine" Description : Path is not valid
I added a connection (ADO.NET) object by name testCon in the connection manager - I wanted to programmatically supply the connection string. So I used the "Expressions" property of the connection object and set the connectionstring to one DTS variable. The idea is to supply the connection string value to the variable - so that the connection object uses my connection string.
Then I added a "Backup Database Task" to my package with the name BkpTask. Now whenever I try to set the connection property of BkpTask to the testCon connection object, by typing testCon, it automatically gets cleared. I am not able to set the connection value.
Then after spending several hours I found that this is because I have customized the connection string in testCon. If I don't customize the connection string, I am able to enter the "testCon" value in the connection property of the BkpTask.
When I try to create an SSIS package with an FTP task, it always fails to compile with the messages:
Error at Package: The connection "" is not found. This error is thrown by Connections collection when the specific connection element is not found. Error at FTP Task [FTP Task]: Connection manager "" can not be found. Error at FTP Task: There were errors during task validation. (Microsoft.DataTransformationServices.VsIntegration)
The item is marked with a circled-X. The tool-tip also agrees: The connection "" is not found.
Using my recreation steps below, I am setting up a connection manager, but it is never found at compile time.
1. Open BIDS, select a new Integration Services project. 2. Drag an FTP task from the toolbox to the Control Flow window. 3. Double-click the FTP task. 4. On the FTP Task Editor window, General page, pull down the FTPConnection property. 5. Select <New Connection...> 6. On the FTP Connection Manager Editor window, enter the servername, port, username and password. 7. Click "Test Connection" to verify connectivity. (It succeeds.) 8. Click OK on the FTP Connection Manager Editor window. 9. Click OK on the FTP Task Editor window.
I'm not using a configuration file or logging provider for this example. I have also installed SP2 + cumulative update 2.
Hi, I'm using Integration Service between Firebird and MS SQL 2005. I can able to move data from Firebird db tables to MS SQL db tables using DataReader source (Firebird Connection Manager) and SQL Server Destination (SQL Server Connection Manager) component.
Now I want to execute parametrized SQL statement to fetch data from Firebird DB using Execute SQL Task Component. In this process while trying to set Connection property to this component I can able to view only MS SQL Connection Manager and it is not listing Firebird Connection Manager. Now I need a help to get connect this Execute SQL Task component with Firebird connection Manager. Help me to find out where I'm making mistake.
I am working on SQL Server 2005 (x64) with Windows Server 2003 (x64) operating system. I am having a major issue in SSIS. Here is the detailed explanation of the issue :
I have an EXCEL file in 2003 / 2007 version. It contains some data. I want to import the data using SSIS into SQL Server 2005 (x64) database table. I have taken "EXCEL FILE SOURCE" and "SQL Server DESTINATION". It was failed on importing data. Surprisingly it works fine in SQL Server 2005 (x32). Can you please explain why it is NOT woking on (x64) ?
Here is the error code i am getting:
[Excel Source [1]] Error: The AcquireConnection method call to the connection manager "Excel Connection Manager" failed with error code 0xC0202009.
I am running into issues with custom objects interaction with visual studio 2005.
1. Custom connection manager. I am setting the name of the connection manager ( to standardize naming convention ) that user created, however when the CM is created, the name displayed in visual studio is still the default name even if the real name is the one i set. I have to do things like, edit it or save package - close - reopen, create another connection, ... etc in order to get it refreshed.
2. Custom Task I am managing some variables in this custom task so that I will be adding and deleting variables in the package. The challenge i am running into is, when I added 2 variables for example, even though the variables are successfully added to package, the Variable Window in visual studio designer will not reflect the new variables. I have to save package, close, and re-open in order for the variables to show up.
So this brings to my question - is there any way to tell Visual Studio programmatically to refresh the contents of these 2 sections, 1 is the Variable Window and the other is the panel containing the list of connection managers.
I have been searching around and found some clue about visual studio SDK but I still cannot find an exact way of doing it. Visual Studio SDK example tells you how you can access the Variable window as
We have an SSIS job that runs once a day and sends emails. For security reasons, IT switched the send-mail porton the smtp server from 25 to a different number (let's say 1234).
So, I changed the SSIS SMTP Connection Manager's smtpServer string to smptserver:1234
However, this does not seem to be working. I keep getting 'Send Mail Failure' error.
Any ideas how to set the port number for sending emails using SSIS?
I am trying to figure out how to override the column delimiter from a script task for a flat file connection.
Before outputing the data into a file, I have a variable which contains the delimiter to be used... but as it seems that this property cannot be changed through an expression, I assume it has to be done throught code...
However, the connectionmanager object doesnt seem to have the delimiter as an available property.
I use SQL Server 2012 and visual studio 2010.I created SSIS Project with task "Execute Package". Control flow view as: Package1 (execute package) -> Package2 (data flow).Data flow in Package2 view as: ADO.NET source -> ADO.NET destination.
When I started Package2, it's work. I havn't errors.But when I started Package 1 I have error "Unable to get managed connection from the Connection Manager runtime". In execution log I see that ADO.NET source produced this error on verification stage. Package failed on verification stage, not on execution stage.Why when I started Package 2 it work, but when I started Package1 (and Package1 started Package2) it failed?
Hi All, I am getting the following error if I am using the package "Transaction Option=Required" while running through Sql Job: The AcquireConnection method call to the connection manager "<connection name>" failed with error code 0xC0202009.
while I running the SSIS package on BI environment, I am getting the following error: [Connection manager "<connection name>"] Error: The SSIS Runtime has failed to enlist the OLE DB connection in a distributed transaction with error 0x8004D00A "Unable to enlist in the transaction.".
I know the alternative solution is to make the "Transaction Option=Supported", but in my case I have run the whole flow in a single transaction. I came to know that this has been fixed in the service pack1(ref. to http://support.microsoft.com/kb/914375). FYI.. some time it was running successful.
I have taken all the necessary step to run the SSIS package in a distributed transaction(like the steps for MSDTC) and also created the package flow in a sequence.
I was going through the link - http://forums.microsoft.com/MSDN/ShowPost.aspx?PostID=160340&SiteID=1 but all those didn't solve my problem.
If anyone can help me it will be great. or it is a bug in SSIS?
Problem: ColA (Source) Rounding error to PARTY_NO (Destination) I have a field of text of in a flat file that the flat file connection manager Source picks up correctly €œ70000893€? However when it gets the OLE DB Connection Destination the data has changed to 70000896. That€™s before its even Written to the database. The only clue that something is wrong in the middle is the great Data viewer shows the number as 7.000009E+07 Other clues looking at the data it appears there is a rounding error on only the number that dont end in 00 ColA (Source) PARTY_NO (Destination) 71167300 71167296 70329000 70329000 70410000 70410000 Any ideas people? Thanks in advance Dave
hi all, i got the error, when i run my package after deploy into the server machine; i can able to run that package in my local machine, if i deploy it to the server or some remote machine, its not running, and rises error messages, that says cant accquire connection from the connection manager;
the problem might be with the login name and password; i could not see any password in any of my config file, or connection manager while running the package. how to resolve this problem?? please help me!
I have a child package where the ConnectionString property of a Connection Manager is set by a Parent Package Variable Configuration. I set up a script task that brings up a message box with the value of the ConnectionString property right before the dataflow task.
MessageBox.Show(Dts.Connections["CPU_*"].ConnectionString.ToString());When I run the parent package, the message box shows that the connection string is changing with every iteration, but in the dataflow it always draws the data from the same source.
The connection manager is an ADO.Net type, RetainSameConnection is set to False, and I've been researching this for days.
(Update 2/23/2015): To make this stranger, when I look at the diagnostic logs, they tell me that when the new connections are being opened they are using the new connection strings.
I've created a SSIS Solution and have created Data Sources. I have two packages. One was created before the Data Sources, and one was created after. The package that was created after is using connections from the Data Sources. I want to change the package before the Data Soruces were created to use them, but when I right click in the Connection Managers pane "New Connection From Data Source.." is not an option.
This is the first time I have used SSIS, so please bear with the ignorance.
I have a super simple package that inserts x000's of rows into a temporary table. The data source is a file that the user will upload. I need to be able to tell the package what file to upload. I'm thinking the simplest thing would be to edit the connectionString property of the SourceConnectionFlatFile at runtime. Is this possible? What form should the file path be in (UNC, other)? And, are there any other considerations I should be aware of?
Is there a way by which we can make the Connection in the connection manager retry for a certain amount of time?
I have a DataFlow Task which uses a OLE Source which is connected to a database. there are time when the connection to the database is not available due to some transport level error. so i wanted the connection manger to make a couple of tries before giving up and saying that it was not able to connect and it timed out..
i have the Connect TimeOut and the General Timeout properties set to 0, but is there a way to retry?
My source files are in C:Process folder. File names are in the format proc*.csv
I am using foreach loop container to iterate over the files in folder "C:Process"
I have a user variable "filename"
The order of my tasks
ForEach - Data Flow task - File System Task
In Data Flow task, I have ole db source which should take the dynamic filename from user variable "filename". whats happening is when i give fixed filename, without foreach loop container the package is working fine.
with dynamic filename, I am not able to run the package because of ole db source Error - cannot aquire connection from connection manager.
I have deleted one of my file connection from Connection Manager (and
Executed ProcessTask which used it), however
trying to load the package I always get the error:
"Error loading MyPackage.dtsx: The connection "MyDeletedConnectionName" is not found. This error is thrown by Connections collection when the specific connection element is not found."
I tried to Clean, Rebulid my project, but it doesn't help.
Does anybody know, how to solve it? Where this reference is saved?