Unable To Extract From Stored Procedure
Jul 30, 2007
hi everyone
ive written a stored procedure which returns a value depending on the i/p parameter
ive executed it in the object browser
but i cant extract it from the stored proc to the front end
create procedure checking ( @username varchar(20), @password varchar(20) ,@result int out)
as
if @username ='admin'
set @result = 1
else
set @result = 0
return @result
GO
and this is what i wrote in the code behind
SqlCommand check = new SqlCommand("checking",con);//checking is the stored procedure
check.CommandType = CommandType.StoredProcedure;
check.Parameters.Add(new SqlParameter("@username", SqlDbType.VarChar)).Value = TxtUsername.Value;
check.Parameters.Add (new SqlParameter("@password", SqlDbType.VarChar)).Value = TxtPassword.Value;
check.Parameters.Add(new SqlParameter("@result", SqlDbType.Int)).Value = 0;
int status = ( Convert.toint32 )check.executenonquery();// the line which is prolly causing the error , can u tell me what should be written here?
the status returns -1
View 2 Replies
ADVERTISEMENT
Jul 20, 2005
Is there anyway to extract part of a string in a stored procedureusing a parameter as the starting point?For example, my string might read: x234y01zx567y07zx541y04zMy Parameter is an nvarchar and the value is: "x567y"What I want to extract is the two charachters after the parameter, inthis case "07".Can anyone shed some light on this problem?Thanks,lq
View 4 Replies
View Related
May 21, 2008
The my_stored_procedure returns a result set of values for attribute "id" and "name".
My attempt to extract just the id values from my_stored_procedure has a syntax error:
Code Snippetselect id from (execute my_stored_procedure);
I want to use it in a query
Code Snippet
if 32 in (Select id from (execute my_stored_procedure));
select 1 as valid;
What€™s the correct way to do this?
Thank you.
View 5 Replies
View Related
Jan 25, 2008
I am stuck on how to syntactically retrieve an output value (@ProdCount) from a stored procedure. The SPROC works fine: the value of @ProdCount appears correctly in the output window. However, I can't retrieve it in the DAL handler (value remains 0). Does anyone have an idea on how to properly extract the return value. TIA for any pointers.SPROC (abridged): ALTER PROCEDURE and_Store_GetProductsByProdCatID_SortPage (@ProdCatID INT,...@ProdCount INT OUTPUT
)
ASSELECT @ProdCount=(SELECT COUNT(*) FROM and_StoreProduct WHERE ProdCatID= @ProdCatID)DECLARE @SQL nvarchar(4000)SET @SQL = 'WITH tmpProd AS ( SELECT ROW_NUMBER() etc.. )SELECT ProdID, etc..FROM tmpProdWHERE Row BETWEEN etc..ORDER BY etc..'
EXECUTE(@SQL)RETURNDAL handler (abridged): Public Overloads Shared Function GetProductListByCatID(ByVal ProdCatID As Integer, ..., ByVal ProdCount As Integer) As List(Of Product) Dim productList As List(Of Product) = New List(Of Product) Try
Using con As New SqlConnection(ConfigurationManager.ConnectionStrings("conAnders").ConnectionString) Dim cmd As SqlCommand = New SqlCommand("and_Store_GetProductsByProdCatID_SortPage", con) cmd.CommandType = CommandType.StoredProcedure cmd.Parameters.AddWithValue("@ProdCatID", ProdCatID) '...
cmd.Parameters.AddWithValue("@ProdCount", ProdCount) ' Output parm. Add dummy value.
Dim objProduct As Product 'Temp Product.
con.Open()
Using myReader As SqlDataReader = cmd.ExecuteReader(CommandBehavior.CloseConnection) While myReader.Read() objProduct = New Product() With objProduct .ProdID = myReader.GetInt32(myReader.GetOrdinal("ProdID")) 'etc..
End With
productList.Add(objProduct)
End While Dim tmp As Object = cmd.Parameters("@ProdCount").Value ' <-- Not updated
myReader.Close() End Using End Using Catch ex As Exception Throw ' Pass up the error.
End Try Return productList End Function
View 8 Replies
View Related
Jun 4, 2004
I tried to create a stored procedure but instead of opening up to a new stored procedure it displays an exist stored procedure. I erased the code and typed in my code now i received this error message.
MS SQL-DMO (ODBC SQLState:42000)
Error 2729: Procedure ‘spUpdate_date_time’ group number 1 already exists
in the database. Choose another procedure name
Does anyone know how I can fix this?
Your help is appreciated
View 2 Replies
View Related
Jan 2, 2007
Hi everyone
I am trying something that should be so simple but I cant get it to work. I am calling a stored procedure to lock a table and update a counter. I have tried to follow the exact code use in the MSDN examples but it doesnt work and always returns VT_EMPTY. It also returns a closed recordset so attempting to close it fails. The database is updated correctly and there are no exceptions just no return value.
Here is the stored procedure
CREATE PROCEDURE GETMODELID AS
DECLARE @i INT
BEGIN TRANSACTION
SET @i=(SELECT ModelID from tblModelID WITH (HOLDLOCK,TABLOCKX))+1
UPDATE tblModelID SET ModelID = @i
COMMIT TRANSACTION
RETURN @i
GO
Here is the ADO written in C++.
TDatabase DB;
try
{
if(DB.Open()==false)
{
AfxMessageBox(DB.m_ErrStr);
return FALSE;
}
_variant_t vtEmpty2 (DISP_E_PARAMNOTFOUND, VT_ERROR);
_CommandPtr spCMD;
CREATEiNSTANCE(spCMD,Command);
spCMD->ActiveConnection = DB.m_Cnn;
spCMD->CommandText = "GETMODELID" ;
spCMD->CommandType = adCmdStoredProc;
spCMD->Parameters->Refresh();
_RecordsetPtr spRS;
_variant_t vRa;
spRS = spCMD->Execute( &vRa, &vtEmpty2, adCmdStoredProc );
_variant_t rtn(DEF_PARAM(spCMD,0L));
DB.Close();
return (int) rtn;
}
View 3 Replies
View Related
Jul 20, 2005
Hi all,I have a internet page written in asp to submit into authorscurriculum vitae publications (title, author, year, etc.).If the author submit less than 8000 characters it functions OK, but Ifthe author try's to submit more than 8000 characters the asp page doesnot return an error but the text is not saved in the database or,sometimes, it returned a "Typ mismatch" error.Here is the sp:---------------------------------------------------------------------CREATE PROCEDURE sp_CV_publications(@formCommandnvarchar(255)='process',@id numeric=null,@id_personint=null,@typPubID tinyint= NULL,@publicationstext=null)ASif @formCommand='process'beginINSERT INTO CV_publications(idperson,typPubID,publications)VALUES (@id_person@typPubID,@publications);select 1 as status, @@IDENTITY AS insertedID, * FROMCV_publications WHERE id=@@IDENTITYend----------------------------------------------------------------------------The server is running IIS5 and SqlServer 2000Any ideas ???
View 1 Replies
View Related
Aug 25, 2006
Hi All,
In my application on click of Delete button, actually I am not deleting the record. I am just updating the flag. But before updating the record I just want to know the dependency of the record ie. if the record I am deleting(internally updating) exists any where in the dependent tables, it should warn the user with message that it is available in the child table, so it can not be deleted. I want to check the dependency dynamically. For that I have written the following procedure. But it is updating in both cases.
CREATE proc SProc_DeleteRecord
@TableName varchar(50),
@DeleteCondition nVarchar(200)
As
Begin
Begin Transaction
Declare @DelString nvarchar(4000)
set @DelString = 'Delete from ' + @TableName + ' where ' + @DeleteCondition
execute sp_executeSql @DelString
RollBack Transaction --because i donot want to delete the record in any case
If @@Error <> 0
Begin
select '1'
End
Else
Begin
Declare @SQLString nvarchar(4000)
set @SQLString = 'Update ' + @TableName + ' set DeletedFlag=1 where ' + @DeleteCondition
execute sp_executeSql @SQLString
select '0'
End
End
Thanks & Regards
Bijay
View 4 Replies
View Related
Oct 31, 2007
Hi all,
I've created a database named HyperCodexDB.mdf and I'm trying to extract some information from, I've no error, but the code after Open() method is even not executed:
Here is the Web.Config
and in the .cs file :
Hashtable names = new Hashtable();
int i = 0;
string conn_str = ConfigurationManager.ConnectionStrings["hcConnectionString"].ConnectionString;
SqlConnection con = new SqlConnection(conn_str);
SqlCommand cmd;
cmd = new SqlCommand("SELECT Nom FROM TableRecueil", con);
SqlDataReader rdr = null;
try
{
Label1.Text = "Hello"; ////////????Here changes the value of the label
con.Open();
Label1.Text = "Bye"; ////////????But here the value of Label1.Text remains "Hello"
rdr = cmd.ExecuteReader();
while (rdr.Read())
{
names.Add(i, rdr["Nom"]);
i++;
}
Label1.Text = names[0].ToString();
}
catch (SqlException ex){ }
finally
{if (rdr != null)
{rdr.Close();}
if (con != null)
{con.Close();}}
Thanks in advance
Ali
View 8 Replies
View Related
Mar 30, 2006
I'm using a form that has a dropdown control. This dropdown control has items that can be selected that serves as a filter for displaying results on the page that is returned from a stored procedure call. I'm having trouble finding a way to execute the stored procedure to display the filtered results everytime a different item in the dropdown gets selected. Currently, the form does get submitted and the selected item does get saved, but the stored procedure never gets executed on a postback. Any ideas on resolving this issure? Your help is much appreciated.
View 1 Replies
View Related
Feb 15, 2006
Hi all,
When I try to open a connection it gives me error "Stored Procedure sp_sdidebug not found"
Can anyone help me in this respect?
I was running the same application with the SQL Server 2005 only earlier when it was running.But now after I reinstalled VS.NET & SQL Server I am getting this error.What could be the problem?
Please help... I am badly stuck up.
PAM
View 3 Replies
View Related
Mar 12, 2007
I get the following error in a log file created in the osql command:
Msg 3201, Level 16, State 1, Server KAC2KGS2, Procedure usp_Kaman_Full_SqlDB_Backup, Line 150
Cannot open backup device 'x:Servername_master_sqlbu_200703101930.bkf'.
Device error or device off-line. See the SQL Server error log for more
details.
Msg 3013, Level 16, State 1, Server KAC2KGS2, Procedure usp_Kaman_Full_SqlDB_Backup, Line 150
BACKUP DATABASE is terminating abnormally.
The device is established in a CMD file right before the osql command is started that starts my stored procedure. The CMD in this file is:
for /f "tokens=15 delims=." %%i in ('ipconfig^|find "IP Address"^|find "192.168"') do set SUBNET=%%i
:loop
if exist x: net use x: /del
net use x: \192.168.%SUBNET%.1ackup
if not ERRORLEVEL 1 (
goto continue
) else (
echo FAILED TO CONNECT TO BACKUP SERVER >> "%SystemDrive%LogFiles\%Computername%.log"
sleep 60
goto loop
)
:continue
echo IP ADDRESS OBTAINED
Echo delete old log file if it exists
if exist %3\%computername%_kaman_full_sqldb_backup_old.log del /Q %3\%computername%_kaman_full_sqldb_backup_old.log
Echo Rename log file to old.log
rename %3\%computername%_kaman_full_sqldb_backup.log %computername%_kaman_full_sqldb_backup_old.log
echo backup SQL Databases on server will start now
osql -E -n -d %1 -i %2kaman_full_sqldb_backup.sql -h-1 -o %3\%Computername%_kaman_full_sqldb_backup.log
In the stored procedure I try to use the x: drive and that does not work. I have tried obtaining the \192.168.x.x address and that only works on some of my servers. All are running SQL 2000, some are using Win2K and Win2003. It does not seem to matter. One of them that is using Win2003 only fails occationally.
I notice when I do a
exec master..xp_cmdshell 'x:'
The system cannot find the drive specified.
Yet, when I go to the server there is an x drive.
I am using the sqlserv user to run the job and that use is an administrator on the local machine. This is a virtual machine. We add the X before the osql and drop it after the command finishes.
Any help would be appreciated. Thanks, dbmsql
View 6 Replies
View Related
Nov 2, 2015
Created a report that displays the Maximum Response time (example of value 00:00:00) which is directly pulled from the Stored proc.When I ran the report, the column displays blank values.I am not sure if I should add any conversion to the Response value in the report.
View 2 Replies
View Related
Jun 11, 2015
We are executing a SSIS package using a xp_cmdshell command in a SP as shown below. This package does consumes time to execute almost 90 minutes and does get executed successfully too. But the strange thing is we don't get the result in @result variable just because somehow the next sql statement after the below highlighted statement doesn't get executed at all. Â After checking execution stats for the SP using the query attached below we observed that somehow the SP vanishes out of the execution stats for the server.
 SELECT @cmd = 'dtexec /FILE "D:Program FilesMicrosoft SQL Server100DTSPackages.....PopulateReport.dtsx"'     Â
 SELECT @cmd = @cmd + ' /Decrypt T@!0er '     Â
 SELECT @cmd = @cmd + ' /set package.variables[vAppID].Value;' + CONVERT(VARCHAR(10),@appId)     Â
 SELECT @cmd = @cmd + ' /set package.variables[vDBName].Value;' + '"' + @db + '"'     Â
 SELECT @cmd = @cmd + ' /set package.variables[vBuildMFF].Value;' + CONVERT(VARCHAR(10),@BuildMFF)     Â
Â
[code]....
View 6 Replies
View Related
Oct 2, 2014
I have a MySql Database i need to extract data from based on matching info in a local SQL Server database,
I will ultimately need to cycle through 20 of these MySql databases , but the query below is taking 1 minute and 20 plus seconds...Just for one..
Is there a simple tweak that would speed it up?
USE [CAS]
GO
DECLARE @PhoneDB varchar(max),
@SQL NVARCHAR(MAX);
set @PhoneDB = '[PHONEDB_PHI]';
set @SQL = 'SELECT
[Code]....
View 4 Replies
View Related
Apr 2, 2007
hi anyone can tell me how to extract procedure code from database
nisar
View 4 Replies
View Related
May 11, 2004
Hello,
I had a problem.
I need to transfert tables between from and SQl Server V7 to and Oracle 8I database.
One of my MS-SQL table look like this:
table mySQLtable(
id int,
filetype nvarchar(5),
binaryfile image)
My Oracle destination table is :
table msOracletable(
id number not null,
filetype varchar2(64),
bynaryfile blob)
;
How can I extract datas from my SQL table, specially the binaryfile and
import datas into my Oracle table ?
Can somebody help me ?
View 3 Replies
View Related
Nov 1, 2007
Hi all - I'm trying to optimized my stored procedures to be a bit easier to maintain, and am sure this is possible, not am very unclear on the syntax to doing this correctly. For example, I have a simple stored procedure that takes a string as a parameter, and returns its resolved index that corresponds to a record in my database. ie
exec dbo.DeriveStatusID 'Created'
returns an int value as 1
(performed by "SELECT statusID FROM statusList WHERE statusName= 'Created')
but I also have a second stored procedure that needs to make reference to this procedure first, in order to resolve an id - ie:
exec dbo.AddProduct_Insert 'widget1'
which currently performs:SET @statusID = (SELECT statusID FROM statusList WHERE statusName='Created')INSERT INTO Products (productname, statusID) VALUES (''widget1', @statusID)
I want to simply the insert to perform (in one sproc):
SET @statusID = EXEC deriveStatusID ('Created')INSERT INTO Products (productname, statusID) VALUES (''widget1', @statusID)
This works fine if I call this stored procedure in code first, then pass it to the second stored procedure, but NOT if it is reference in the second stored procedure directly (I end up with an empty value for @statusID in this example).
My actual "Insert" stored procedures are far more complicated, but I am working towards lightening the business logic in my application ( it shouldn't have to pre-vet the data prior to executing a valid insert).
Hopefully this makes some sense - it doesn't seem right to me that this is impossible, and am fairly sure I'm just missing some simple syntax - can anyone assist?
View 1 Replies
View Related
Oct 22, 2013
I would like to extract a file from a database. The file is stored in a BLOB format
Can I extract the BLOB file from the database using an SQL code/command or is there another way in which I can extract the file?
The file is stored as a BLOB but is actually a ZIP file (if that makes any difference)
What is the normal method of extracting a BLOB file?
View 3 Replies
View Related
May 21, 2008
Hi Folks,
I am writing a program that transforms a generic MS SQL database to make it compatible with our application. In order to make the transformation, I have to access all the elements of the generic database programmatically.
I know that the Master database contains all this information. Is there a query that allows me to access the "non-system" tables, sps, views, and functions?
For Tables, I need to know the Name(s) of the tables, the column names, the column type, ALLOW Nulls, Primary Key, Identity Seed settings, and Triggers.
For SPs, I need to know the Name(s) and access the SP source code (assuming it's unencrypted).
For Views, I need to know the Name(s) and access the Views Source
For functions, I need to know the Name(s) and access the function source.
I can see various tables in the Master database from management studio, like sys.objects, sys.tables - which look like they have the info I need. However, when I run a query against master like:
select * from sys.objects .. I get an error:
Msg 208, Level 16, State 1, Line 1
Invalid object name 'sys.objects'.
Thank you in advance.
View 13 Replies
View Related
Mar 3, 2008
Hi all,
I have 2 sets of sql code in my SQL Server Management Stidio Express (SSMSE):
(1) /////--spTopSixAnalytes.sql--///
USE ssmsExpressDB
GO
CREATE Procedure [dbo].[spTopSixAnalytes]
AS
SET ROWCOUNT 6
SELECT Labtests.Result AS TopSixAnalytes, LabTests.Unit, LabTests.AnalyteName
FROM LabTests
ORDER BY LabTests.Result DESC
GO
(2) /////--spTopSixAnalytesEXEC.sql--//////////////
USE ssmsExpressDB
GO
EXEC spTopSixAnalytes
GO
I executed them and got the following results in SSMSE:
TopSixAnalytes Unit AnalyteName
1 222.10 ug/Kg Acetone
2 220.30 ug/Kg Acetone
3 211.90 ug/Kg Acetone
4 140.30 ug/L Acetone
5 120.70 ug/L Acetone
6 90.70 ug/L Acetone
/////////////////////////////////////////////////////////////////////////////////////////////
Now, I try to use this Stored Procedure in my ADO.NET-VB 2005 Express programming:
//////////////////--spTopSixAnalytes.vb--///////////
Public Class Form1
Private Sub Button1_Click(ByVal sender As System.Object, ByVal e As System.EventArgs) Handles Button1.Click
Dim sqlConnection As SqlConnection = New SqlConnection("Data Source = .SQLEXPRESS; Integrated Security = SSPI; Initial Catalog = ssmsExpressDB;")
Dim sqlDataAdapter As SqlDataAdapter = New SqlDataAdaptor("[spTopSixAnalytes]", sqlConnection)
sqlDataAdapter.SelectCommand.Command.Type = CommandType.StoredProcedure
'Pass the name of the DataSet through the overloaded contructor
'of the DataSet class.
Dim dataSet As DataSet ("ssmsExpressDB")
sqlConnection.Open()
sqlDataAdapter.Fill(DataSet)
sqlConnection.Close()
End Sub
End Class
///////////////////////////////////////////////////////////////////////////////////////////
I executed the above code and I got the following 4 errors:
Error #1: Type 'SqlConnection' is not defined (in Form1.vb)
Error #2: Type 'SqlDataAdapter' is not defined (in Form1.vb)
Error #3: Array bounds cannot appear in type specifiers (in Form1.vb)
Error #4: 'DataSet' is not a type and cannot be used as an expression (in Form1)
Please help and advise.
Thanks in advance,
Scott Chang
More Information for you to know:
I have the "ssmsExpressDB" database in the Database Expolorer of VB 2005 Express. But I do not know how to get the SqlConnection and the SqlDataAdapter into the Form1. I do not know how to get the Fill Method implemented properly.
I try to learn "Working with SELECT Statement in a Stored Procedure" for printing the 6 rows that are selected - they are not parameterized.
View 11 Replies
View Related
Nov 14, 2014
I am new to work on Sql server,
I have One Stored procedure Sp_Process1, it's returns no of columns dynamically.
Now the Question is i wanted to get the "Sp_Process1" procedure return data into Temporary table in another procedure or some thing.
View 1 Replies
View Related
Jan 29, 2015
I have some code that I need to run every quarter. I have many that are similar to this one so I wanted to input two parameters rather than searching and replacing the values. I have another stored procedure that's executed from this one that I will also parameter-ize. The problem I'm having is in embedding a parameter in the name of the called procedure (exec statement at the end of the code). I tried it as I'm showing and it errored. I tried googling but I couldn't find anything related to this. Maybe I just don't have the right keywords. what is the syntax?
CREATE PROCEDURE [dbo].[runDMQ3_2014LDLComplete]
@QQ_YYYY char(7),
@YYYYQQ char(8)
AS
begin
SET NOCOUNT ON;
select [provider group],provider, NPI, [01-Total Patients with DM], [02-Total DM Patients with LDL],
[Code] ....
View 9 Replies
View Related
Sep 19, 2006
I have a requirement to execute an Oracle procedure from within an SQL Server procedure and vice versa.
How do I do that? Articles, code samples, etc???
View 1 Replies
View Related
Dec 28, 2005
I have a sub that passes values from my form to my stored procedure. The stored procedure passes back an @@IDENTITY but I'm not sure how to grab that in my asp page and then pass that to my next called procedure from my aspx page. Here's where I'm stuck: Public Sub InsertOrder() Conn.Open() cmd = New SqlCommand("Add_NewOrder", Conn) cmd.CommandType = CommandType.StoredProcedure ' pass customer info to stored proc cmd.Parameters.Add("@FirstName", txtFName.Text) cmd.Parameters.Add("@LastName", txtLName.Text) cmd.Parameters.Add("@AddressLine1", txtStreet.Text) cmd.Parameters.Add("@CityID", dropdown_city.SelectedValue) cmd.Parameters.Add("@Zip", intZip.Text) cmd.Parameters.Add("@EmailPrefix", txtEmailPre.Text) cmd.Parameters.Add("@EmailSuffix", txtEmailSuf.Text) cmd.Parameters.Add("@PhoneAreaCode", txtPhoneArea.Text) cmd.Parameters.Add("@PhonePrefix", txtPhonePre.Text) cmd.Parameters.Add("@PhoneSuffix", txtPhoneSuf.Text) ' pass order info to stored proc cmd.Parameters.Add("@NumberOfPeopleID", dropdown_people.SelectedValue) cmd.Parameters.Add("@BeanOptionID", dropdown_beans.SelectedValue) cmd.Parameters.Add("@TortillaOptionID", dropdown_tortilla.SelectedValue) 'Session.Add("FirstName", txtFName.Text) cmd.ExecuteNonQuery() cmd = New SqlCommand("Add_EntreeItems", Conn) cmd.CommandType = CommandType.StoredProcedure cmd.Parameters.Add("@CateringOrderID", get identity from previous stored proc) <------------------------- Dim li As ListItem Dim p As SqlParameter = cmd.Parameters.Add("@EntreeID", Data.SqlDbType.VarChar) For Each li In chbxl_entrees.Items If li.Selected Then p.Value = li.Value cmd.ExecuteNonQuery() End If Next Conn.Close()I want to somehow grab the @CateringOrderID that was created as an end product of my first called stored procedure (Add_NewOrder) and pass that to my second stored procedure (Add_EntreeItems)
View 9 Replies
View Related
Sep 26, 2014
I have a stored procedure and in that I will be calling a stored procedure. Now, based on the parameter value I will get stored procedure name to be executed. how to execute dynamic sp in a stored rocedure
at present it is like EXECUTE usp_print_list_full @ID, @TNumber, @ErrMsg OUTPUT
I want to do like EXECUTE @SpName @ID, @TNumber, @ErrMsg OUTPUT
View 3 Replies
View Related
Mar 28, 2007
I have a stored procedure that calls a msdb stored procedure internally. I granted the login execute rights on the outer sproc but it still vomits when it tries to execute the inner. Says I don't have the privileges, which makes sense.
How can I grant permissions to a login to execute msdb.dbo.sp_update_schedule()? Or is there a way I can impersonate the sysadmin user for the call by using Execute As sysadmin some how?
Thanks in advance
View 9 Replies
View Related
Jan 23, 2008
Has anyone encountered cases in which a proc executed by DTS has the following behavior:
1) underperforms the same proc when executed in DTS as opposed to SQL Server Managemet Studio
2) underperforms an ad-hoc version of the same query (UPDATE) executed in SQL Server Managemet Studio
What could explain this?
Obviously,
All three scenarios are executed against the same database and hit the exact same tables and indices.
Query plans show that one step, a Clustered Index Seek, consumes most of the resources (57%) and for that the estimated rows = 1 and actual rows is 10 of 1000's time higher. (~ 23000).
The DTS execution effectively never finishes even after many hours (10+)
The Stored procedure execution will finish in 6 minutes (executed after the update ad-hoc query)
The Update ad-hoc query will finish in 2 minutes
View 1 Replies
View Related
Sep 13, 2007
Hi all,
I am trying to debug stored procedure using visual studio. I right click on connection and checked 'Allow SQL/CLR debugging' .. the store procedure is not local and is on sql server.
Whenever I tried to right click stored procedure and select step into store procedure> i get following error
"User 'Unknown user' could not execute stored procedure 'master.dbo.sp_enable_sql_debug' on SQL server XXXXX. Click Help for more information"
I am not sure what needs to be done on sql server side
We tried to search for sp_enable_sql_debug but I could not find this stored procedure under master.
Some web page I came accross says that "I must have an administratorial rights to debug" but I am not sure what does that mean?
Please advise..
Thank You
View 3 Replies
View Related
Mar 7, 2008
Please help me to get the xml from procedure in asp 64 bit system.
The below code is executed in 32-bit system and display the XML in browser. But if you run the same code in 64-bit system (windows 2003 standard R2) the values replaced with question marks and it it displayed the following error.
I am using SQl server 2000 as a DataBase.
This is very urgent.
Blow is the code with file name test64bit.asp
<%
Dim str_XML
dim cn
set cn = server.createobject("adodb.connection")
cn.ConnectionString = "Provider=SQLOLEDB;User ID=sa;Password=Password;Initial Catalog=northwind;Data Source=SystemName;Network Library=DBMSSOCN;"
cn.Mode = adModeReadWrite
cn.Open
set rsXml = Server.CreateObject("Adodb.recordset")
strSql = "select * from Products for xml auto"
rsXml.open strSql ,cn
while not rsXml.EOF
response.write rsXml(0).value
str_XML = str_XML & rsXml(0)
rsXml.MoveNext
wend
rsXml.close
response.write "str_XML::" & str_XML & "<br>"
%>
Following is the error
?ProductID?ProductName?SupplierID?CategoryID?Quant ityPerUnit?UnitPrice?UnitsInStock?UnitsOnOrder?Reo rderLevel?Discontinued?Products?Al
Microsoft VBScript runtime error '800a000d'
Type mismatch
/ASP/test64bit.asp, line 21
View 2 Replies
View Related
Mar 31, 2008
I have a stored procedure 'ChangeUser' in which there is a call to another stored procedure 'LogChange'. The transaction is started in 'ChangeUser'. and the last statement in the transaction is 'EXEC LogChange @p1, @p2'. My questions is if it would be correct to check in 'LogChange' the following about this transaction: 'IF @@trancount >0 BEGIN Rollback tran' END Else BEGIN Commit END.
Any help on this would be appreciated.
View 1 Replies
View Related
Oct 10, 2006
Hi,I am getting error when I try to call a stored procedure from another. I would appreciate if someone could give some example.My first Stored Procedure has the following input output parameters:ALTER PROCEDURE dbo.FixedCharges @InvoiceNo int,@InvoiceDate smalldatetime,@TotalOut decimal(8,2) outputAS .... I have tried using the following statement to call it from another stored procedure within the same SQLExpress database. It is giving me error near CALL.CALL FixedCharges (@InvoiceNo,@InvoiceDate,@TotalOut )Many thanks in advanceJames
View 16 Replies
View Related
Nov 15, 2006
I have a store procedure (e.g. sp_FetchOpenItems) in which I would like to call an existing stored procedure (e.g. sp_FetchAnalysts). The stored proc, sp_FetchAnalysts returns a resultset of all analysts in the system.
I would like to call sp_FetchAnalysts from within sp_FetchOpenItems and insert the resultset from sp_FetchAnalysts into a local temporary table. Is this possible?
Thanks,
Kevin
View 3 Replies
View Related